| Plan Review Notes For Permit 00070108 |
| Permit Number |
00070108 |
|
| Review Stop |
P |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2001-01-08 00:00:00 | ****************PROVISO***************** | | | 1)WATER RISER DIAGRAM MISSING WATER | | | CLOSET IN WOMEN'S RESTROOM. | | | | | | 2)WATER CLOSET AND FIXTURE BRANCH NOT | | | PERMITTED ON WET VENT PER COUNTYWIDE | | | AMENDMENTS TO SPC SEC.911.1.1.2 WATER | | | CLOSETS MAY BE VENTED PER COUNTYWIDE | | | AMENDMENTS TO SPC SEC.911.1.3. | | | | | | 3)SUBMIT REVISED SANITARY AND WATER | | | RISERS PRIOR TO PLUMBING INSPECTION. | | | COUNTYWIDE AMENDMENTS TO SPC SEC.104.2.1 | | | | | | 4)POOL PLANS THAT ARE SIGNED,SEALED AND | | | DATED BY A PROFESSIONAL ENGINEER | | | REGISTERED IN THE STATE OF FLORIDA SHALL | | | BE ROUTED TO THE PALM BEACH COUNTY | | | HEALTH DEPT.FOR REVIEW AND APPROVAL | | | PRIOR TO REVIEW BY THIS DEPARTMENT. | | | COUNTYWIDE AMENDMENTS TO SPC SEC.101.4.7 | | | | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | | ANY QUESTIONS | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER. |
|