| 2001-01-08 00:00:00 | TRUSS DRAWINGS CHECKLIST: |
| | |
| | 1-ARCHITECT TO REVIEW TRUSS LAYOUT AND |
| | ENGINEERED TRUSSES AS WELL AND PROVIDE |
| | REVIEW STAMP WITH THE FIRM LOGO. |
| | (ARCHITECT IS NOT SUPPOSED TO SEAL |
| | ENGINEERED DRAWINGS THAT HE DIDN'T DO) |
| | |
| | 2-ARCHITECT'S FRAMING PLANS AND ANCHOR |
| | SCHEDULE NEED TO BE COORDINATED WITH |
| | TRUSS ENGINEERED DRAWINGS. |
| | - KEYED DETAILS DON'T MATCH ACTUAL |
| | CONDITIONS. SEE SHEET A-8 AND DETAILS |
| | SPECIFIED. |
| | - THERE ARE SEVERAL CONNECTIONS THAT ARE |
| | NOT SPECIFIED. |
| | |
| | NOTE: CLOSELY REVIEW FRAMING PLANS AND |
| | ENGINEERED TRUSSES AND UPDATE/CLARIFY |
| | AS REQUIRED TO AVOID UNNECESSARY |
| | RETURNS. |
| | |
| | 3-PROVIDE UPLIFT CONNECTOR SCHEDULE FOR |
| | FLOOR FRAMING TRUSSES. |
| | |
| | 4-SOME FLOOR TRUSSES ARE MISSING THE |
| | UPLIFT LOADS CALCULATED. |
| | |
| | 5-TRUSSES GENERAL DETAILS WERE NOT |
| | UPDATED AS REQUESTED ON PREVIOUS |
| | CHECKLIST. SEE PREVIOUS CHECKLIST. |
| | |
| | 6-ARCHITECT TO DATE ANY DRAWING THAT IS |
| | SEALED FOR PUBLIC RECORD. FLORIDA |
| | STATUTES, CHAPTER 481. SEE ATTACHED |
| | REMAINDER. |
| | |
| | |
| | |
| | NOTES: |
| | -IF YOU HAVE ANY QUESTIONS, PLEASE CALL |
| | JULIO GOMEZ AT 659-8096 EXT. 8232. |