| 2001-01-08 00:00:00 | DENIED |
| | |
| | 1)PROVIDE 2 CURRENT COPIES OF METRO-DADE |
| | OR SBCCI PRODUCT APPROVALS FOR SPECIFIC |
| | EXTERIOR WINDOWS AND DOORS TO BE USED. |
| | |
| | 2)MISSLE IMPACT PROTECTION IS REQUIRED |
| | FOR ALL EXTERIOR GLAZING.CITY OF WPB |
| | AMENDMENTS TO THE 97 SBC SEC.1606.4. |
| | PROVIDE 2 COPIES OF METRO-DADE OR SBCCI |
| | PRODUCT APPROVALS,KEY PLAN AND INSTALL- |
| | ATION SCHEDULE WITH SPECIFIC TYPE ANCHOR |
| | TO BE USED FOR STORM PANELS. |
| | |
| | 3)SUBMIT 2 COMPLETED CITY OF WPB DESIGN |
| | COMPLIANCE FORMS.1997 SBC OR ASCE 7-95. |
| | |
| | 4)FL ENERGY EFFICIENCY CODE FORMS 600A- |
| | 97 MUST BE SIGNED BY OWNER/AGENT. |
| | |
| | 5)INDICATE ON PLANS LOCATION OF ATTIC |
| | ACCESS AND ATTIC VENTILATION. 97 SBC |
| | 2309.6 AND 2309.7 |
| | |
| | 6)FINISH FLOOR ELEVATION MUST BE MINIMUM |
| | OF 6" ABOVE BASE FLOOD ELEVATION. CITY |
| | CODE CHAPTER 12. PROJECT IS LOCATED IN |
| | A5 FLOOD ZONE EL 7. |
| | |
| | 7)IMPACT FEES MUST BE PAID TO PALM BEACH |
| | COUNTY,PLANS STAMPED BY THEM AND A COPY |
| | OF THE RECIEPT SUBMITTED TO CITY OF WPB |
| | BUILDING DEPT. BEFORE A PERMIT TO |
| | CONSTRUCT WILL BE ISSUED. |
| | |
| | 8)SAFETY GLASS IS REQUIRED IN THE |
| | WINDOWS ADJACENT TO DOORS C AND D ON |
| | PLAN. 97 SBC 2405.2.1 |
| | |
| | 9)INDICATE ON PLANS METHODS OF |
| | ATTACHMENT TO BE USED TO CONNECT STUDS |
| | TO TOP PLATES AND WOOD COLUMNS TO WOOD |
| | HEADERS. |