Plan Review Notes
Plan Review Notes For Permit 00061693
Permit Number 00061693
Review Stop FIRE
Sequence Number 1
Notes
Date Text
2001-01-08 00:00:001) NO FIRE SPRINKLER PLANS OR HYDRAULIC
 CALCULATIONS PROVIDED.
 2) WRONG FIRE CODE REFERENCE, SHOULD
 READ NFPA 101, 1985 EDITION INSTEAD OF
 NFPA 101, 1991 EDITION.
 3) LOWER SOFFIT IN ENTRY AT 7'-1 AFF
 NOT PROPER. HEADROOM IN MEANS OF EGRESS
 SHALL BE 7'-6 OR 6'-8 IF PROJECTED FROM
 CEILING. PLEASE EXPLAIN SOFFIT.
 4) EXITING PERMITTED THRU STOCKROOM ONLY
 IF, NOT MORE THAN 50 PERCENT OF THE
 OCCUPANT LOAD PERMITTED THROUGH
 STOCKROOM.AISLE TO BE AT LEAST 44" WIDE
 AND MAINTAINED IN AN UNOBSTRUCTED
 CONDITION.
 5) INTERIOR FINISH TO BE CLASS A OR B.
 6) ENSURE EMERGENCY LIGHTING IS PROVIDED
 IN STOCKROOM.
 7) FIRE EXTINGUISHERS REQUIRED.