2001-01-08 00:00:001)DOOR 101 SHALL COMPLY W/FACBC SEC.
 4.13.6.(SEE EWC)SAME FOR DOOR 102 AT
 RESTROOM #106.
  
 2)H.C.DRESSING ROOM SHALL COMPLY W/FACBC
 SEC.4.35.4.-BENCH TO BE LOCATED ALONG
 LONGER WALL.
  
 3)WATER CLOSETS AND FIXTURE BRANCHES NOT
 PERMITTED ON WET VENTS.SUBMIT REVISED
 SANITARY RISER PRIOR TO PLBG.INSPECTION.
 COUNTYWIDE AMENDMENTS TO SPC SEC.911.1.1
  
 4)WATER HEATER SHALL BE LISTED.SPC SEC.
 503.3.
  
 5)HANDICAP ACCESSIBLE TOILET ROOMS SHALL
 BE INDELIBLY POSTED FOR THE INTENDED
 USE,BE ON AN ACCESSIBLE ROUTE AND
 AVAILABLE TO PATRONS WITHOUT RESTRICTION
 DURING NORMAL OPERATING HOURS.FACBC SECS
 4.1.3,4.1.2,4.2.1.,4.3.1. 4.3.2.,4.3.3.
 ACCESIBLE ROUTE SHALL BE CLEARLY DEFINED
 ON THE PLANS.
  
 CALL 561-659-8096 IF YOU HAVE ANY
 QUESTIONS.