| 2001-01-08 00:00:00 | SHT.AA-INCORPORATE THE STANDARD PLUMBING |
| | CODE,1994 EDITION INTO CODE COMPLIANCE |
| | DATA LEGEND.COUNTYWIDE AMENDMENTS TO SPC |
| | SEC.101.2,101.4.6.,F.S.553.06. |
| | B)THE ADOPTED STANDARD GAS CODE IS THE |
| | 1997 EDITION. |
| | C)THE ADOPTED ACCESSIBILITY CODE IS THE |
| | FLA.ACCESSIBILITY CODE FOR BUILDING |
| | CONSTRUCTION-OCTOBER 1997 EDITION. |
| | |
| | SUBMIT SQUARE FOOTAGE OF HABITABLE FLOOR |
| | SPACE FOR DETERMINATION OF MINIMUM |
| | SANITARY FACILITIES.SEE SPC SEC.407.1.3. |
| | FOR ALLOWED DEDUCTIBLE AREAS. |
| | |
| | A MINIMUM OF ONE DRINKING FOUNTAIN IS |
| | REQUIRED PER SPC TABLE 407.FOUNTAIN |
| | SHALL COMPLY W/FACBC SEC.4.1.3.(10)(A). |
| | PROVISIONS SHALL BE MADE FOR PEOPLE WHO |
| | HAVE TROUBLE BENDING OR STOOPING. |
| | |
| | DRESSING ROOM SHALL COMPLY W/FACBC SEC. |
| | 4.35.4.(BENCH SHALL BE FIXED ALONG LONG |
| | WALL). |
| | |
| | SHT.A-8A-GRAB BARS ALONGSIDE WATER |
| | CLOSET SHALL BE A MIN.OF 42".DETAILS C & |
| | G NOTE 36". |
| | |
| | FLUSH CONTROLS FOR WATER CLOSETS SHALL |
| | BE LOCATED ON THE WIDE SIDE OF THE |
| | WATER CLOSET PER FACBC SEC.4.16.5. |
| | |
| | SHT.A-8A SHOWS HEIGHT OF ACCESSIBLE |
| | WATER CLOSETS AS 15".COMPLY W/FACBC SEC. |
| | 4.16.3. |
| | |
| | WATER HEATER SHALL BE READILY ACCESSIBLE |
| | PER SPC SEC.501.7.SUPPLY FIXED LADDER |
| | OR RELOCATE EWH TO FLOOR. |
| | |
| | WATER CLOSETS NOT PERMITTED ON WET VENTS |
| | PER COUNTYWIDE AMENDMENTS SEC.911.1.1. |
| | OR COMPLY W/SPC SEC.914.1 FOR CIRCUIT |
| | AND LOOP VEN SYSTEM IF THAT IS THE |
| | INTENT. |