Plan Review Notes
Plan Review Notes For Permit 00060740
Permit Number 00060740
Review Stop B
Sequence Number 1
Notes
Date Text
2001-01-08 00:00:001. FLORIDA ENERGY SHEETS: SUBMIT
 ORIGIONAL SIGNED AND SEALED DOCUMENT
 1997 FL. ENERGY CODE.
 2. FIRE SPRINKLER PERMIT REQUIRED PRIOR
 TO ISSUANCE OF BUILDING PERMIT.
 3. SHEET A-0 BOTH SIDES OF FIRE
 SEPARATION MUST BE FINISHED.
 4. SHEET A-1 STORAGE ABOVE RESTROOMS
 PROVIDE STAIR FOR ACCESS SEE SECTION
 1005.7 MEZZANINES AND GUSARD RAILS SEE
 SECTION 1015 1997 SBC.
 5. SHEET A-4 NOTE 16: PROVIDE PRODUCT
 APPROVAL INFORMATION FOR LARGE MISSLE
 IMPACT PROTECTION OF EXTERIOR GLAZED
 OPENINGS, MEET 1997 SBC, SSTD 12-97 OR
 METRO DADE COUNTY.
 5. EXTERIOR SIGNS REQUIRE SEPERATE
 PERMITS.
 6. ALL WOOD PRODUCTS SHALL BE PRESSURE
 TREATED FIRE RETARDANT LUMBER AND
 PROTECTED BY ATHERMAL BARRIER SEE
 1997 SBC, SECTION 707.