| 2001-01-08 00:00:00 | APPROVED WITH PROVISO: |
| | 1-FLOOD ZONE "AO". PROVIDE ELEVATION |
| | CERTIFICATE. |
| | 2-PROVIDE CURRENT PRODUCT APPROVAL FOR |
| | SLIDING GLASS DOORS. OR PROVIDE A |
| | COMPLETE SITE SPECIFIC ENGINEERING |
| | ANALYSIS WITH ALL CALCULATIONS, COPIES |
| | OF STRUCTURAL TESTS PERFORMED AS PER |
| | ASTM E-330, COMPLETE INSTALLATION |
| | DETAILS INCLUDING FASTENING TO THE |
| | STRUCTURE. AND INCLUDE SITE SPECIFIC |
| | FORM (ATTACHED) SIGNED, SEALED AND |
| | DATED BY THE MANUFACTURER'S ENGINEER |
| | AND THE ARCHITECT OF RECORD. |
| | 3-TWO HOUR CONCRETE BLOCK: PROVIDE |
| | CERTIFICATION FROM MANUFACTURER |
| | ENGINEER STATING THAT CONCRETE BLOCK |
| | EQUIVALENT THICKNESS COMPLIES WITH |
| | ASTM C140 FOR FIRE RESISTANCE. |
| | SECTION 709.3 SBC 1997. |
| | 4-PROVIDE PRODUCT APPROVAL FOR WINDOW |
| | MULLIONS. |
| | 5-COMPLETELY SPECIFY CEILING CONSTRUCT'N |
| | AT ENTRY AND REAR PORCHES. |
| | INCLUDE ALL FASTENERS TYPES AND SPAC'G |
| | SECTION 2504 SBC 1997. |
| | 6-REVISE ROOF TRUSS ANCHOR SCHEDULE AS |
| | REQUIRED. NEED TO SPECIFY WOOD TO WOOD |
| | CONNECTORS AT PORCHES' ROOF TRUSSES |
| | ANCHORED TO WOOD BEAMS. |
| | 7-SEE COMMENTS BY OTHER TRADES. SEE LAST |
| | TWO PAGES OF THE BLUE PRINTS. |