| 2001-01-08 00:00:00 | 1)SINK IN LUNCH ROOM SHALL COMPLY W/ |
| | FACBC SECS.4.24.1-4.24.7. |
| | |
| | 2)THE WIDTH OF THE ACCESSIBLE TOILET |
| | STALL IN THE MEN'S RESTROOM SHALL COMPLY |
| | W/FACBC SEC.4.17.3. |
| | |
| | 3)SUBMIT DETAILS/MOUNTING HEIGHTS FOR |
| | ALL HANDICAP FIXTURES AND APPURTENANCES. |
| | COMPLY W/ALL APPLICABLE SECTIONS OF THE |
| | FLA.ACCESSIBILITY CODE. |
| | |
| | 4)THE SANITARY AND WATER RISER DIAGRAMS |
| | SHALL CORRELATE W/THE FLOOR PLAN. |
| | |
| | 5)PRIVACY SCREENS ARE REQD.BETWEEN |
| | URINALS.SPC SEC.404.3. |
| | |
| | 6)FLOOR DRAINS ARE REQD.IN THE 1ST FLR. |
| | TOILET ROOM.(NOT SHOWN ON SAN.RISER.) |
| | SPC SEC.409.4.1.1. |
| | |
| | 7)FIXTURE BRANCHES AND WATER CLOSETS ARE |
| | NOT PERMITTED ON WET VENTS.IF DESIGNING |
| | FOR A CIRCUIT AND LOOP SYSTEM COMPLY W/ |
| | SPC SEC.914.1 |
| | |
| | 8)NOTE ON THE PLANS THE NUMBER OF |
| | SEATS IN THE CAFE AREA AND SQUARE FEET |
| | OF HABITABLE FLOOR SPACE FOR THE TOTAL |
| | SALES AREA TO ENSURE COMPLIANCE W/SPC |
| | TABLE 407 FOR MIN.SANITARY REQS.. |
| | |
| | 9)DRINKING FOUNTAINS SHALL NOT REDUCE |
| | THE CLEAR WIDTH OF AN ACCESSIBLE ROUTE. |
| | FACBC SEC.4.4.1. |
| | |
| | 10)WATER RISER MISSING SIZES ON LINES. |
| | PLEASE ADDRESS THESE AREAS SO THEY CAN |
| | BE REVIEWED FOR COMPLIANCE. |
| | |
| | CALL 561-659-8096,EXT.8377 IF YOU HAVE |
| | ANY QUESTIONS. |
| | TIMOTHY LARGE |
| | PLUMBING PLANS EXAMINER. |