 1. PROVIDE COMPLETED FLORIDA ENERGY
 SHEETS SIGNED AND SEALED BY DESIGNER
 OF RECORD AS PER FLORIDE STSTUTE.
 2. FIRE SPRINKLER CONTRACTOR MUST SECURE
 PERMIT PRIOR TO ISSURANCE OF THE
 BUILDING PERMIT.
 3. SHOW THAT ESCULATOR COMPLIES WITH
 SECTION 705.2.2 1997 SBC.
 4. DJ BOOTH MUST BE ACCESSABLE AS
 REQUIRED BY THE FLORIDA ACCESSABILITY
 CODE FOR BUILDING CONSTRUCTION CODE
 EDITION 1997.RE DOORS SEE FIGURE 25,
 STAIR RAILING SEE FIGURE 19, DJ BOOTH
 SEE CHAPTER 4.
 6.
  
  
 PROVISO
  
 1.HEALTH DEPARTMENT APPROVAL REQUIRED
 FOR FOOD SERVICE AREA.
 2.SUBMIT EFIS PRODUCT APPROVAL FOR
 WIND LOADS CHAPTER 1606, AND FIRE
 RESISTANCE CHAPTER 26, 1997 SBC
 3.SUBMIT EXTERIOR GLAZING PRODUCT
 APPROVAL INFORMATIOM, COMPLY WITH 1997
 STANDARD BUILDING CODE SSTD 12-97 OR
 METRO DADE COUNTY.