Plan Review Notes
Plan Review Notes For Permit 00051243
Permit Number 00051243
Review Stop R
Sequence Number 2
Notes
Date Text
2001-03-29 00:00:00SECOND CHECKLIST:
 1-BEDROOM WINDOWS DON'T COMPLY WITH THE
 EGRESS REQUIREMENTS. SEC 1005.4.2 AND
 SEC. 1005.4.4 SBC 1997.
 2-SURVEY DOESN'T MATCH FLOOR PLAN AND
 PLOT PLAN ON SHEET #2.
 -REVISE BUILDING DIMENSIONS, SETBACKS,
 DRIVEWAYS, BUILDING FOOTPRINT, ETC.
 3-PROFESSIONAL ENGINEER OF RECORD TO
 DATE HIS DRAWINGS WHEN SEALING AND
 SIGNING DOCUMENTS FOR PUBLIC RECORDS
 AS REQUIRED BY CHAPTER 471 FL STATUTES
 4-ROOF TRUSS DRAWINGS:
 -ALL TRUSS DRAWINGS TO BE REVIEWED BY
 THE PROFESSIONAL DESIGNER OF RECORD.
 -DESIGNER OF RECORD IS USING SBC 1997
 DESIGN CRITERIA. TRUSSES ARE DESIGNED
 BASED ON ASCE 7-93. MIXING OF THE TWO
 CODES IS NOT ALLOWED. SEE SEC 1606.1.2
 SBC 1997. REVISE AS REQUIRED.
 -CONNECTOR SPECIFIED FOR TRUSS T03 AT
 BEARING POINT #8 DOESN'T WORK. REVISE
 AS REQUIRED. SEE TRUSS PROFILE.
 -TRUSS ENGINEER TO DATE ALL DRAWINGS AT
 TIME OF SEALING THEM AS REQUIRED BY
 FLORIDA STATUTES, CHAPTER 471.
 SEE ALL GENERAL DETAILS.
 5-PROVIDE CURRENT PRODUCT APPROVAL FOR:
 -AWNING WINDOWS (PRODUCT APPROVAL IS
 EXPIRED)
 -OCTAGON WINDOWS.
 -WINDOW MULLIONS
 6-STORM PANELS:
 -PROVIDE KEY PLAN AND A COMPLETE
 INSTALLATION SCHEDULE (SEE SAMPLE).
 -CLEARLY INDICATE ON DRAWINGS SPECIFIC
 MOUNTING CONDITIONS AND ANCHOR TYPE
 AND SPACING TO BE USED ACCORDING TO
 THE MEAN ROOF HEIGHT,DESIGN PRESSURES,
 PANEL SPAN, CONNECTION TYPE, EDGE
 DISTANCE AND STRUCTURE TO BE ATTACHED
 TO (MASONRY).
 -THERE ARE THREE DIFFERENT TYPES OF
 STORM SHUTTERS SUBMITTED (ROLL UP,
 ACCORDION AND STORM PANELS), CLARIFY
 WHICH ONE IS GOING TO BE USED AND
 PROVIDE THE KEY PLAN, INSTALLATION
 SCHEDULE AND ALL REQUIRED INFORMATION.
 7-INFORMATION ON ROOF FRAMING PLAN ON
 SHEET #4 IS EXTREMELY LIGHT AND IS NOT
 SUITABLE FOR MICROFILMING FOR PUBLIC
 RECORDS. CORRECT AS REQUIRED.
 8-OWES $827.34 FOR LOW VALUATION, RADON
 FEES AND INCREASE ON THE SQUARE
 FOOTAGE OF THE ADDITION.
 NOTE: SOME FEES MAY HAVE BEEN PAID
 FROM PREVIOUS CHECKLIST. PLEASE BRING
 COPIES OF THE PAID RECEIPTS TO
 VERIFY WHAT WAS PAID.
 9-SPECIFY FIREBLOCKING ON WALL SECTION.
 SECTION 2305 SBC 1997.
 10-SPECIFY SIZE OF VENTS FOR ROOF
 VENTILATION. SEC. 2309.7 SBC 1997.
 11-PLANS WERE CHANGED FROM ORIGINAL
 SUBMITTAL. SEE ZONING COMMENTS
 ATTACHED.
 -IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 659-8096 EXT. 8232.