| Date |
Text |
| 2001-01-08 00:00:00 | CHECKLIST: |
| | 1-PAY IMPACT FEES TO PALM BEACH COUNTY. |
| | BRING STAMPED DRAWINGS AND RECEIPT. |
| | 2-BEDROOM WINDOWS DON'T COMPLY WITH |
| | EGRESS REQUIREMENTS, SECTION 1005.4 |
| | SBC 1997. |
| | 3-ENGINEER TO CLEARLY INCLUDE HIS NAME, |
| | LICENSE NUMBER, ADDRESS. |
| | -ENGINEER TO PROVIDE DATE WHEN DRAWINGS |
| | ARE SEALED. |
| | 4-PROVIDE SURVEY SHOWING NEW BUILDING |
| | LAYOUT. SIGNED, SEALED AND DATED. |
| | 5-PROVIDE ATTIC ACCESS IN FAMILY ROOM |
| | WING. SECTION 2309.6 SBC 1997. |
| | 6-PROVIDE SOIL TEST REPORT. |
| | 7-PROVIDE ENGINEERED ROOF TRUSS DWGS. |
| | REVIEWED BY THE PROFESSIONAL DESIGNER |
| | OF RECORD. |
| | -SPECIFY ATTACHMENT OF NEW ROOF TRUSSES |
| | OVER EXISTING ROOF. NOTE: TAKE INTO |
| | CONSIDERATION EAST WING WHERE EXISTING |
| | ROOF TRUSSES AND NEW ROOF TRUSSES SEEM |
| | TO BE RUNNING PERPENDICULAR TO EACH |
| | OTHER. |
| | -PROVIDE COMPLETE CONSTRUCTION DETAIL |
| | AND SPECIFICATIONS FOR INSTALLATION OF |
| | GIRDER TRUSS TO RECEIVE EXISTING ROOF |
| | TRUSSES AT FAMILY ROOM WING. PROVIDE |
| | SHORING SPECIFICATIONS. |
| | SECTION 104.2.2 CITY AMENDMENTS. |
| | 8-PROVIDE BUCK DETAIL FOR OPENINGS OVER |
| | 12'-0" WIDE. SEE WINDOW/DOOR BUCK |
| | INSTALLATION TABLE ON DRAWING #6. |
| | 9-COMPLETELY FILL ALL THE INFORMATION |
| | ON THE DESIGN CERTIFICATION FOR BLDG |
| | CODE COMPLIANCE FORM AND ENGINEER TO |
| | DATE DOCUMENT AT TIME OF IMPRESSING |
| | HIS SEAL. FLORIDA STATUTES CHAPTER 471 |
| | 10-OWNER/AGENT TO SIGN AND DATE THE |
| | ENERGY CALCULATIONS TO CERTIFY |
| | COMPLIANCE WITH FLORIDA ENERGY CODE. |
| | 11-PROVIDE CURRENT PRODUCT APPROVALS FOR |
| | SLIDING, AWNING, SLIDING AND OCTAGON |
| | WINDOWS, FRENCH DOORS, ROOF TILE. |
| | 12-STORM PANELS: |
| | -PROVIDE PRODUCT APPROVAL WITH LEGIBLE |
| | DRAWINGS. |
| | -PROVIDE A COMPLETE INSTALLATION SCHED, |
| | AS PER CITY SAMPLE ATTACHED, AND KEY |
| | PLAN. |
| | -CLEARLY INDICATE ON PRODUCT APPROVAL |
| | DRAWINGS THE SPECIFIC MOUNTING |
| | CONDITIONS AND ANCHOR TYPE AND SPACING |
| | TO BE USED IN THIS HOUSE ACCORDING TO |
| | THE MEAN ROOF HEIGHT, DESIGN PRESURES, |
| | EDGE DISTANCE, STORM PANEL SPAN AND |
| | STRUCTURE TO BE ATTACHED TO (CONCRETE, |
| | MASONRY OR WOOD). |
| | 13-OWES $379.63 FOR LOW VALUATION AND |
| | RADON FEES. SEE ATTACHED RECEIPT. |
| | |
| | |
| | NOTES: |
| | 1-SEE COMMENTS BY OTHER TRADES. |
| | 2-PLEASE RETURN REVIEWED SETS IN ORDER |
| | TO EXPEDITE THE REVIEW PROCESS. |