2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-SOIL TEST REPORT CALLS FOR A MINIMUM
 18" WIDE FOOTING. SHEET A1 CALLS FOR
 F-2 TO BE 16" WIDE X 18" DEEP. REVISE
 ORIGINAL DRAWING AS REQUIRED. ALSO,
 SOIL TEST ENGINEER NEED TO SIGN, SEAL
 AND DATE REPORT. SIGNATURE TO BE HAND
 WRITTEN, NOT STAMPED.
 2-SHEET A.2.1: MEAN ROOF HEIGHT TO BE
 18'-0" PLUS OR MINUS. MEAN ROOF HEIGHT
 IS TAKEN FROM GRADE, NOT FROM FINISH
 FLOOR, TO THE AVERAGE POINT OF THE
 HIGHEST ROOF.
 3-STORM PANELS:
 -PROVIDE A COMPLETE INSTALLLATION SCHED
 AS PER CITY SAMPLE.
 -CLEARLY INDICATE MOUNTING CONDITIONS
 AND ANCHOR TYPE AND SPACING TO BE USED
 ACCORDING TO THE DESIGN PRESSURES
 (CHECK MEAN ROOF HEIGHT), STORM PANEL
 SPAN, EDGE DISTANCE AND STRUCTURE TO
 BE ATTACHED TO.
 4-LETTER FROM ROYAL PALM ALUMINUM
 MANAGER OF ENGINEERING CERTIFYING THE
 ARCHITECTURAL SHAPED WINDOWS NEED TO
 BE SIGNED, SEALED AND DATED BY THE
 ENGINEER. IN ADDITION NEED TO WRITE
 LICENSE NUMBER OF ENGINEER.