| Date |
Text |
| 2001-01-08 00:00:00 | CHECKLIST: |
| | 1-PAY IMPACT FEES TO PALM BEACH COUNTY. |
| | PLEASE, GET DRAWINGS STAMPED AND BRING |
| | PAID RECEIPT. |
| | 2-PROVIDE EGRESS AT BEDROOM. SECTION |
| | 1005.4.4 SBC 1997. WINDOWS SPECIFIED |
| | DON'T PROVIDE THE MINIMUM EGRESS SIZE. |
| | 3-PROVIDE COPY OF NOTICE OF COMMENCEMNT. |
| | 4-ADDITION IS GOING TO BE ADJACENT TO |
| | EXISTING GARAGE. AMOUNT OF OPENINGS |
| | ALLOWED ARE RESTRICTED BY TABLE 600 OF |
| | SBC 1997. PLEASE, REVISEDRAWINGS AS |
| | REQUIRED TO COMPLY WITH TABLE 600. |
| | 5-STORM PANELS: |
| | -PROVIDE A COMPLETE INSTALLATION |
| | SCHEDULE (SEE ATTACHED SAMPLE) AND KEY |
| | PLAN SHOWING LOCATION OF OPENINGS TO |
| | BE PROTECTED. |
| | -STORM PANEL DRAWINGS: HIGHLIGHT |
| | SPECIFIC MOUNTING CONDITIONS AND |
| | ANCHOR TYPE AND SPACING TO BE USED. |
| | 6-PROVIDE VENTILATION FOR BATHROOM. |
| | SECTION 1203.4.2 SBC 1997. |
| | -NOTE 1:SAME THING APPLIES TO EXISTING |
| | BEDROOM AND BATHROOM WHERE EXISTING |
| | WINDOWS ARE BLOCKED BY THE ADDITION. |
| | -NOTE 2: PROVIDE EGRESS WINDOW FOR |
| | EXISTING BEDROOM WHERE WINDOW IS BEING |
| | BLOCKED BY THE NEW ADDITION. |
| | EGRESS WINDOW SECTION 1005.4.4 SBC/97. |
| | 7-PROVIDE PRODUCT APPROVALS FOR: SINGLE |
| | HUNG WINDOWS (INCLUDING COMPLETE AND |
| | LEGIBLE DRAWINGS),EXTERIOR SWING DOOR, |
| | ROOF SHINGLES FOR A WIND VELOCITY OF |
| | 110 MPH. |
| | 8-CONTRACTOR NEEDS TO UPDATE THE LICENSE |
| | AND INSURANCE. |
| | |
| | |
| | |
| | NOTE: |
| | -IF YOU HAVE ANY QUESTIONS, PLEASE FEEL |
| | FREE TO CONTACT JULIO GOMEZ AT 659-8096 |
| | EXT. 8232. |