| Plan Review Notes For Permit 00050892 |
| Permit Number |
00050892 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-01-08 00:00:00 | SUBMIT OCCUPANT LOAD BASED ON HABITABLE | | | FLOOR SPACE PER SPC 407.1.3.COMPLY W/SPC | | | TABLE 407 FOR MINIMUM REQD.SANITARY | | | FACILITIES. | | | | | | SINK IN EMPLOYEE LOUNGE SHALL BE | | | ACCESSIBLE PER FACBC SEC.4.24.1.-4.24.7. | | | | | | SHOWER SHALL BE ACCESSIBLE PER FACBC | | | SEC.4.1.2(6). | | | | | | A DRINKING FOUNTAIN IS REQD.PER TABLE | | | 407 OF SPC.FOUNTAIN SHALL COMPLY W/ | | | FACBC SEC.4.1.3.(10)(A).PROVISIONS SHALL | | | BE MADE FOR PEOPLE WHO HAVE TROUBLE | | | BENDING OR STOOPING. | | | | | | INDICATE WALL FINISH IN TOILET ROOM PER | | | SBC 1204.2. | | | | | | SHT.A-9-WATER CLOSET SHALL BE 18" FROM | | | WALL,NOT 20" AS SHOWN.SEE FIGURE 28 OF | | | FACBC. | | | | | | CLEARLY SHOW SCUPPER SIZE.COMPLY W/SPC | | | SEC.1109.1,1109.2,1109.3. | | | | | | SUBMIT COMPLETE SANITARY,STORM,AND WATER | | | ISOMETRICS FOR REVIEW.SPC 104.2.1. | | | SHOW SQ.FOOTAGE DRAINED BY EACH ROOF | | | DRAIN. | | | | | | SUBMIT CIVIL DRAWINGS FOR ANY NEW SITE | | | UTILITIES TO BE INSTALLED. |
|