| Date |
Text |
| 2001-01-08 00:00:00 | APPROVED WITH PROVISO: |
| | 1-REVISE ENERGY CALCULATIONS: THERE ARE |
| | FOUR BEDROOMS, NOT 3. SEE PLANS. |
| | 2-PROFESSIONAL ENGINEER SHOULD NOT SEAL |
| | ORIGINAL DRAWINGS. SEC 61G15-23.002. |
| | ALSO, SURVEYOR TO PROVIDE WET |
| | SIGNATURE AND DATE WHEN SEALING DWG. |
| | 3-PROVIDE PRODUCT APPROVAL FOR: |
| | -ONE HOUR FIRE RATED EGRESS PANEL. |
| | -DOUBLE ENTRY DOORS. |
| | -FRENCH DOORS. |
| | -GARAGE DOORS THAT MEET THE DESIGN |
| | PRESSURES CALCULATED BY THE ARCHITECT. |
| | -WINDOW MULLIONS. |
| | -FIXED WINDOWS WITH THE SIZES SHOWN AT |
| | THE GREAT ROOM. |
| | 4-PROVIDE COMPLETE DETAIL/SPECIFICATIONS |
| | FOR CEILING CONSTRUCTION AT ENTRY AND |
| | REAR PORCH. INCLUDE FASTENER TYPE AND |
| | SPACING. SECTION 2504 SBC 1997. |
| | 5-SPECIFY SIZE OF ATTIC ACCESS PANELS. |
| | SECTION 2309.6 SBC 1997. |
| | 6-PROVIDE COMPLETE CONNECTION DETAIL AT |
| | BOTTOM OF STEEL COLUMNS. SEC 104.2.2 |
| | 7-REVISE TYPICAL WALL SECTION AND |
| | FOUNDATION NOTES. MINIMUM 6 MIL VAPOR |
| | BARRIER. SECTION 1909.2 SBC 1997. |
| | 8-SPECIFY SIZE OF CEILING FANS AS PER |
| | TABLE 6-6 OF FLORIDA ENERGY EFFICIENCY |
| | CODE FOR BUILDING CONSTRUCTION, 1997 |
| | 9-REVISE THE DESIGN CERTIFICATION FOR |
| | BUILDING CODE COMPLIANCE FORM: |
| | -MEAN ROOF HEIGHT IS WRONG. MEAN ROOF |
| | HEIGHT IS TAKEN FROM GRADE, NOT FROM |
| | FINISH FLOOR, TO THE AVERAGE POINT OF |
| | THE HIGHEST ROOF. |
| | -SEE CHAPTER 16 OF SBC 1997 FOR THE |
| | CORRECT VALUES FOR THE BASIC VELOCITY |
| | PRESSURE AND THE IMPORTANCE FACTOR. |
| | 10-PROVIDE COPIES OF THE SOIL TESTS DONE |
| | AS PER SEC 1804.2.7.3 CITY AMENDMENTS |
| | 11-ARCHITECT'S GENERAL NOTES ON SHEET GN |
| | SPECIFIES WINDOWS, DOORS AND ROOF TILE |
| | WHICH ARE DIFFERENT FROM THE PRODUCT |
| | APPROVALS SUBMITTED. ARCHITECT TO |
| | APPROVE ALL PRODUCT APPROVALS PRIOR TO |
| | SUBMITTAL TO THIS OFFICE. |
| | 12-SEE COMMENTS ON PLANS, INCLUDING |
| | THOSE BY THE OTHER TRADES AND REVISE |
| | ORIGINALS AS REQUIRED. |
| | |
| | |
| | NOTE: |
| | |
| | INFORMATION REQUESTED ON THIS PROVISO |
| | SHALL BE SUBMITTED PRIOR TO INSTALLATION |
| | TO AVOID CONFLICT OR DELAYS. |