| Notes |
| Date |
Text |
| 2001-01-08 00:00:00 | CONTINUATION OF PLUMBING COMMENTS: | | | 24)CIRCUIT AND LOOP SYSTEM SHALL COMPLY | | | W/SPC SEC.914.1,914.2. | | | | | | 25)A VENT IS REQD.BETWEEN THE SHOWER AND | | | THE JANITOR SINK.SPC SEC.901.2. | | | | | | 26)WATER CLOSETS AND FIXTURE DRAINS ARE | | | NOT PERMITTED ON WET VENTS PER COUNTY- | | | WIDE AMENDMENTS TO SPC SEC.911.1.1. | | | | | | 27)TWO WATER CLOSETS SHALL BE VENTED PER | | | COUNTYWIDE AMENDMENTS SEC.911.1.3. | | | | | | 28)FIXTURES DOWNSTREAM OF WATER CLOSETS | | | SHALL BE VENTED PER SPC SEC.913.2. | | | | | | 29)SUBMIT COMPLETE SANITARY AND WATER | | | RISERS FOR ALL AREAS.(KIT.,3RD.FLR.,ETC. | | | | | | 30)SANITARY RISER SHALL CORRELATE W/ | | | FLOOR PLAN.COUNTYWIDE AMENDMENTS TO SPC | | | SEC.104.2.1. | | | | | | 31)A PERMIT MAY BE REQD.FROM DEPT.OF | | | ENVIRONMENTAL PROTECTION FOR THE WATER | | | AND SANITARY LINE.COUNTYWIDE AMENDMENTS | | | TO SPC SEC.101.4.7. |
|