2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-PROVIDE SOIL TEST REPORT FOR LOT 49.
 REPORT SUBMITTED IS FOR LOT 41.
 2-PROVIDE BUCK DETAIL USING A 2X BUCK
 AS PER SPECIFICATIONS SHOWN ON PRODUCT
 APPROVAL FOR ENTRY DOORS.
 3-UPDATE ALL GENERAL DETAILS SUBMITTED
 WITH THE ENGINEERED TRUSSES PACKAGE.
 CURRENT CODE IS SBC 1997 OR ASCE 7-95.
 CLARIFY WHY THERE ARE SEVERAL ENGINEER
 SEALS ON THE SAME SHEET. REMEMBER THAT
 WET SIGNATURE AND DATE SHALL BE DONE
 AT TIME OF SEALING THE DRAWING.
 4-STORM PANELS:
 -PRODUCT APPROVAL REPORT DOESN'T MATCH
 STORM PANELS DRAWING.
 -GENERAL NOTE # 10 OF SHEET 1 OF 5 OF
 STORM PANELS DRAWINGS REQUIRES THAT
 THIS DRAWINGS NEED TO BE SIGNED AND
 SEALED.
 -HIGHLIGHT SPECIFIC MOUNTING CONDITIONS
 AND ANCHOR SPACING ACCORDING TO THE
 DESIGN PRESSURES, STORM PANELS SPAN
 AND EDGE DISTANCE.
 5-PROVIDE PRODUCT APPROVAL FOR GOLF CART
 DOOR.
 NOTE: PRODUCT APPROVAL MUST MEET THE
 DESIGN PRESSURES CALCULATED BY THE
 ARCHITECT.