| Date |
Text |
| 2001-01-08 00:00:00 | APPROVED WITH PROVISO: |
| | 1-PROVIDE CURRENT PRODUCT APPROVAL FOR |
| | MASONRY. |
| | 2-MULLION PRODUCT APPROVAL IS TO BE USED |
| | WITH SERIES 7500 SINGLE HUNG WINDOWS |
| | MULLED TOGETHER ONLY. PROVIDE MULLION |
| | PRODUCT APPROVAL FOR HORIZONTAL |
| | APPLICATIONS. |
| | -CLEARLY INDICATE MULLION SIZES AND |
| | FASTENERS TO BE USED IN THIS PROJECT. |
| | -PROVIDE UPDATED PRODUCT APPROVAL. |
| | 3-PROVIDE PRODUCT APPROVAL FOR SLIDING |
| | GLASS DOORS WITH TRANSOM ABOVE AS A |
| | SINGLE ASSEMBLY. SEE ARCHITECT'S PLANS |
| | 4-PROVIDE STORM PANELS PRODUCT APPROVAL. |
| | -INDICATE SPECIFIC MOUNTING CONDITIONS |
| | AND ANCHOR TYPE AND SPACING TO BE USED |
| | ACCORDING TO THE DESIGN PRESSURES, |
| | MEAN ROOF HEIGHT, EDGE DISTANCE, PANEL |
| | SPAN AND STRUCTURE TO BE ANCHORED TO. |
| | 5-UPDATE/REVISE ALL DRAWINGS AS REQUIRED |
| | SEE COMMENTS ON PLANS. |
| | 6-PROVIDE COMPLETE FRAMING DETAILS AT |
| | ARCHED OPENINGS. SECTION 104.2.2 OF |
| | CITY AMENDMENTS. |
| | 7-PROVIDE SOIL TEST REPORT WITH THE |
| | MINIMUM INFORMATION AS REQUESTED IN |
| | SECTION 1804.2.7.2 CITY AMENDMENTS. |
| | 8-ATTIC ACCESS TO BE 22"X36" MIN. SEC. |
| | 2309.6 SBC 1997. REVISE NOTE #7 ON A-2 |
| | 9-PROVIDE CURRENT PRODUCT APPROVAL FOR |
| | "LA PORTE" FRENCH DOORS. |
| | 10-CLEARLY INDICATE ON PLANS AREAS TO |
| | HAVE SAFETY GLASS. SEC. 2405.2 SBC/97. |
| | 11-ENERGY CALCULATIONS: |
| | -REVISE CEILING AREA CALCULATIONS. SEE |
| | SECTION 604.1.A.1 FLORIDA ENERGY |
| | EFFICIENCY CODE FOR BUILDING |
| | CONSTRUCTION, 1997 EDITION. |
| | 12-UPDATE NOTE #3 ON SHEET S-3. USE |
| | ASCE 7-95 AT 145 MPH. |
| | 13-CLEARLY INDICATE ON ROOF FRAMING PLAN |
| | THE DETAILS SHOWN ON S-1 THAT APPLY TO |
| | THIS PROJECT. |
| | 14-SPECIFY WHICH PRODUCT APPROVAL IS |
| | REFERRING TO IN DETAIL 3 OF SHEET A-5. |
| | GARAGE BUCK DETAIL. |