| 2001-01-08 00:00:00 | APPROVED WITH PROVISO: |
| | 1-UPDATE THE DESIGN CERTIFICATION FOR |
| | BUILDING CODE COMPLIANCE FORM. SEE |
| | ATTACHED. MAKE SURE SEAL IS LEGIBLE. |
| | 2-MASONRY LETTER BY CSR RINKER: |
| | -UPDATE LETTER AND ENGINEER TO SIGN, |
| | SEAL AND DATE CROSS SECTIONS DETAILS |
| | AND SAFE LOADS. |
| | -PROVIDE LEGIBLE DRAWINGS. |
| | 3-MULLION PRODUCT APPROVAL IS TO BE USED |
| | WITH SERIES 7500 WINDOWS MULLED |
| | TOGETHER ONLY. PROVIDE MULLION PRODUCT |
| | APPROVAL FOR HORIZONTAL APPLICATIONS |
| | AND MULLION FOR TRANSOMS ABOVE DOORS. |
| | -CLEARLY INDICATE WHAT MULLION SIZE AND |
| | FASTENERS ARE GOING TO BE USED FOR |
| | EACH APPLICATION. |
| | -PROVIDE UPDATED PRODUCT APPROVAL. |
| | 4-NEED STORM PANELS PRODUCT APPROVAL. |
| | -HIGHLIGHT SPECIFIC MOUNTING CONDITIONS |
| | AND ANCHOR TYPE AND SPACING ACCORDING |
| | TO THE DESIGN PRESSURES (MEAN ROOF HT) |
| | EDGE DISTANCE, PANEL SPAN AND ANCHOR'G |
| | STRUCTURE. |
| | 5-SIZE OF ATTIC ACCESS TO BE 22"X36" MIN |
| | SECTION 2309.6 SBC 1997. REVISE NOTE 7 |
| | 6-UPDATE ALL DRAWINGS. THIS CITY HAS |
| | ADOPTED SBC 1997.SEE COMMENTS ON PLANS |
| | 7-PROVIDE COMPLETE FRAMING DETAILS AT |
| | ALL ARCHED OPENINGS. SECTION 104.2.2 |
| | CITY AMENDMENTS TO SBC 1997. |
| | 8-PROVIDE COMPLETE DETAIL/SPECIFICATIONS |
| | FOR CEILING CONSTRUCTION AT ENTRY AND |
| | REAR PORCHES. SECTION 2504.2 SBC 1997. |
| | INCLUDING FASTENER TYPE AND SPACING. |
| | 9-PROVIDE COMPLETE HEADER/MULLION DETAIL |
| | AT ENTRY DOORS. BET. DOOR AND TRANSOM. |
| | 10-PROVIDE COPIES OF CURRENT PRODUCT |
| | APPROVAL FOR "LA PORTE" FRENCH DOORS. |
| | 11-PROVIDE SOIL TEST REPORT WITH THE |
| | MINIMUM INFORMATION AS REQUESTED ON |
| | SECTION 1804.2.7.2 OF CITY AMENDMENTS. |