2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-PROVIDE ROOF FRAMING PLAN SHOWING THE
 CALCULATED UPLIFT LOADS AND ANCHOR
 SCHEDULE. SEC. 104.2.2 CITY AMENDMENTS
 2-REVISE THE DESIGN CERTIFICATIONFOR
 BUILDING CODE COMPLIANCE. MEAN ROOF
 HEIGHT IS 23'-6" PLUS OR MINUS, NOT
 20'-0". MEAN ROOF HEIGHT IS TAKEN FROM
 GRADE, NOT FROM FINISH FLOOR, TO THE
 AVERAGE POINT OF THE HIGHEST ROOF.
 3-PRODUCT APPROVALS:
 -PROVIDE PRODUCT APPROVAL FOR GOLFCART
 GARAGE DOOR.
 -FRENCH DOOR PRODUCT APPROVAL: DRAWINGS
 ARE NOT LEGIBLE.
 -PROVIDE PRODUCT APPROVAL FOR "INSWING"
 ENTRY DOORS.
 4-CLARIFY SIZE OF FOOTING F-1. SHEET 1
 SAYS 18"X18" AND SHEET 6 SAYS 20"X18".
 5-PROVIDE COMPLETE SET OF ENGINEERED
 ROYAL WALL PANELS SHOWING ALL CONCRETE
 THICKNESS AND REINFORCEMENT. SIGNED,
 SEALED AND DATED.
 SECTION 104.2.2 CITY AMENDMENTS.