Plan Review Notes
Plan Review Notes For Permit 00031590
Permit Number 00031590
Review Stop R
Sequence Number 1
Notes
Date Text
2001-01-08 00:00:00PLAN #1, DESIGN COMPLIANCE STATEMENT
 HAS THE INCORRECT BASIC VELOCITY PRESSUR
 FOR A MEAN ROOF HEIGHT OF 18 FEET.
 DO NOT WRITE IN CHANGES SUBMIT REVISED
 PLAN.*** INSERT NEW PLAN IN SET ***
  
  
 THE SOILS REPORT NEEDS THE ORIGINAL
 SIGNATURE OF THE ENGINEER WITH DATE.
  
  
 THE REAR ELEVATION ILLUSTRATE A FIXED
 WINDOW IN THE MASTER BEDROOM. NOTE THAT
 THE WINDOWS IN ALL BEDROOMS ARE REQUIRED
 TO PROVIDE A MEANS OF EGRESS ACCORDING
 SECT 1005.4 SBC 1997.CLARIFY
  
  
 PROVIDE THE ENGINEER CALCULATION USED
 FOR DETERMING THE WIND PRESSURES FOR THE
 OVERHEAD GARAGE DOOR.NOTE THAT THE
 END ZONES ARE REQUIRED TO BE A MINIMUM
 OF 3 FEET WIDE.FOR THIS MODEL THE DOOR
 IS LOCATED IN THE END ZONE.
 SECT. 1606.2C SBC 1997
  
  
 THE TRUSS ENGINEERING NEEDS TO SPECIFY
 THE DESIGN CRITERIA, EX SBC 1997, ASCE-
 7-95.ALSO, THE MEAN ROOF HEIGHT DIFFER
 S FROM THE ENGINEERS DESIGNED ROOF
 HEIGHT OF 18' FEET.
  
 THE TRUSS ENGINEERING NEEDS THE RAISED
 SEAL AND ORIGINAL SIGNATURE OF THE
 ENGINEER, JULIUS LEE.
  
 THE TRUSS ENGINEERING AND LAYOUT NEEDS
 TO BE SPECIFY AND HAVE THE BUILDING
 ADDRESS.
  
  
 PROVIDE THE METHOD OF ATTACHING THE
 BEARING WALL TO THE SLAB.PROVIDE A
 ILLUSTRATION SHOWING THE HARWARE CONNECT
 ORS AT THE TOP AND BOTTOM.
  
  
  
  
 OK PER LOU HATTEN


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved