Plan Review Notes
Plan Review Notes For Permit 00031336
Permit Number 00031336
Review Stop R
Sequence Number 1
Notes
Date Text
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-PROVIDE PRODUCT APPROVAL FOR: ENTRY
 DOORS (INSWING), FRENCH DOOR AT MASTER
 SUITE.
 2-PROVIDE ATTIC ACCESS AT MAIN ROOF.
 SECTION 2309.6 SBC 1997.
 3-UPDATE/REVISE PLANS AS REQUIRED. SEE
 COMMENTS ON PLANS.
 4-PROVIDE COMPLETE SPECIFICATIONS FOR
 CONSTRUCTION OF CEILING AT ENTRY AND
 REAR PORCHES. INCLUDE FASTENER TYPE
 AND SPACING. SECTION 2405.2 SBC 1997.
 5-ENGINEER WHO SIGNED AND SEALED THE
 DESIGN CERTIFICATION FOR BUILDING CODE
 COMPLIANCE FORM TO SIGN, SEAL AND DATE
 STRUCTURAL DRAWINGS AS WELL.
 6-ROOF TRUSSES:
 -MEAN ROOF HEIGHT IS 18"-6" PLUS OR
 MINUS. MEAN ROOF HEIGHT IS TAKEN FROM
 GRADE, NOT FROM FINISH FLOOR, TO THE
 AVERAGE POINT OF THE HIGHEST ROOF.
 -UPDATE AND SIGN, SEAL AND DATE ALL
 GENERAL DETAILS TO BE CONSISTENT WITH
 SBC 1997 OR ASCE 7-95.
 7-STORM PANELS:
 -PROVIDE A COMPLETE INSTALLATION SCHED.
 AS PER CITY COPY.
 -HIGHLIGHT SPECIFIC MOUNTING DETAILS
 AND ANCHOR AND SPACING TO BE USED.
 -CHECK THAT KEY PLAN MATCHES CURRENT
 ARCHITECT'S DRAWINGS.