| Plan Review Notes For Permit 00031237 |
| Permit Number |
00031237 |
|
| Review Stop |
R |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-01-08 00:00:00 | APPROVED WITH PROVISO: | | | 1-FLOOD ZONE "AO". WILL NEED ELEVATION | | | CERTIFICATE. | | | 2-CLEARLY INDICATE ON PLANS GLAZING | | | AREAS TO HAVE SAFETY GLAZING. SEE | | | COMMENTS ON PLANS. | | | SECTION 2405.2 SBC 1997. | | | 3-PROVIDE PRODUCT APPROVAL FOR OUTSWING | | | ENTRY DOOR WITH SIDELITE ASSEMBLY. | | | PLEASE MAKE SURE DRAWINGS ARE LEGIBLE. | | | 4-PROVIDE COPIES OF THE TEST RESULTS FOR | | | SLIDING GLASS DOORS AS PER ASTM E-330. | | | SECTION 1706 SBC 1997. | | | 5-STORM PANELS: | | | -REVISE KEY PLAN AND INSTALLATION SCHED | | | TO MATCH ARCHITECT'S PLAN ON SHEET A-8 | | | -USE MASONRY ANCHOR SPACING WHEN PANELS | | | ARE TO BE ATTACHED TO MASONRY COLUMNS | | | WITH FILLED CELLS. | | | 6-UPDATE ALL DRAWINGS. SEE COMMENTS ON | | | PLANS. |
|