2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-REVISE/UPDATE SEE COMMENTS ON PLANS.
 2-REVISE DESIGN CERTIFICATION FOR
 BUILDING CODE COMPLIANCE FORM. MEAN
 ROOF HEIGHT IS INCORRECT. MEAN ROOF
 HEIGHT IS 19'-8" PLUS OR MINUS. MEAN
 ROOF HEIGHT IS TAKEN FROM GRADE, NOT
 FROM FINISH FLOOR, TO THE AVERAGE
 POINT OF THE HIGHEST ROOF.
 3-PROVIDE PRODUCT APPROVAL FOR SLIDING
 GLASS DOORS WITH TRANSOM ABOVE
 ASSEMBLY, ARCHED WINDOWS.
 4-REVISE TRUSS ANCHOR SCHEDULE TO RESIST
 THE UPLIFT LOADS CALCULATED ON THE
 ENGINEERED TRUSSES. FOR EXAMPLE SEE
 TRUSS FG1. CHECK ALL OTHERS AS WELL.
 5-PROVIDE THE DESIGN PRESSURES AT ALL
 EXTERIOR OPENINGS.
 6-PROVIDE SURVEY WITH BUILDING LAYOUT.
 7-STORM PANELS:
 -INSTALLATION SCHEDULE AND KEY PLAN TO
 MATCH PLANS FOR 4 BEDROOMS LAYOUT.
 -CLEARLY IDENTIFY MOUNTING CONDITIONS
 AND ANCHORS AND SPACING TO BE USED.
 8-CLARIFY WHO IS THE STRUCTURAL ENGINEER
 FOR THIS HOUSE. THE SITE SPECIFIC
 PRODUCT APPROVAL IS SIGNED AND SEALED
 BY ONE ENGINEER. THE DESIGN
 CERTIFICATION FOR BUILDING CODE
 COMPLIANCE IS SIGNED AND SEALED BY
 ANOTHER ENGINEER. BUT, NEITHER OF
 THESE ENGINEERS SIGNED AND SEALED THE
 STRUCTURAL DRAWINGS.