| Plan Review Notes For Permit 00030426 |
| Permit Number |
00030426 |
|
| Review Stop |
R |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-01-08 00:00:00 | APPROVED WITH PROVISO: | | | 1-FLOOD ZONE "AO". PROVIDE ELEVATION | | | CERTIFICATE. | | | 2-CLEARLY INDICATE WINDOWS TO HAVE | | | SAFETY GLASS. SECTION 2405.2 SBC 1997. | | | 3-REVISE ENERGY CALCULATIONS: | | | -FLOOR AREA UNDER ATTIC TO BE INCREASED | | | AS REQUIRED. SEE SECTION 602.1.ABC.1.2 | | | FLORIDA ENERGY CODE, 1997 EDITION. | | | 4-PROVIDE PRODUCT APPROVAL FOR ENTRY | | | DOOR WITH SIDELITE ASSEMBLY AND FOR | | | EXTERIOR FRENCH DOOR AT MASTER SUITE. | | | 5-STORM PANELS: | | | -CLARIFY WHY THE INSTALLATION SCHEDULE | | | SPECIFIES ANCHOR SPACING TO BE 12" OC, | | | WHILE, ANCHOR SCHEDULE ON SHEET 6 OF | | | 15 OF APPROVED DRAWINGS IS BEING | | | HIGHLIGHTED DIFFERENTLY. | | | -CLEARLY SPECIFY WHICH STORM PANELS ARE | | | GOING TO BE INSTALLED IN CONCRETE AND | | | WHICH ARE GOING TO BE INSTALLED ON | | | MASONRY. NOTICE THE DIFFERENCE ON | | | ANCHOR SPACING. | | | 6-REVISE/UPDATE ALL PLANS AS REQUIRED. | | | SEE COMMENTS ON PLANS. |
|