Plan Review Notes
Plan Review Notes For Permit 00030283
Permit Number 00030283
Review Stop R
Sequence Number 1
Notes
Date Text
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE "AO" NEED TO PROVIDE
 ELEVATION CERTIFICATE.
 2-REVISE SIZE OF EGRESS WINDOW IN BEDRM
 #2. IT DOESN'T COMPLY WITH SECTION
 1005.4.4 SBC 1997.
 3-REVISE SIZE OF ATTIC ACCESS PANEL.
 MINIMUM SIZE TO BE 22"X36" AS PER
 SECTION 2309.6 SBC 1997.
 4-STORM PANELS:
 -CLARIFY WHY THE INSTALLATION SCHEDULE
 SPECIFIES ANCHOR SPACING 12" AT ALL
 PANELS, BUT ANCHOR SCHEDULE ON SHEET
 6 OF 15 OF APPROVED DRAWINGS IS
 HIGHLIGHTED DIFFERENTLY.
 5-CLEARLY INDICATE ON ORIGINAL DRAWINGS
 THE WINDOWS TO HAVE SAFETY GLASS AS
 PER SECTION 2405.2 SBC 1997.
 6-PROVIDE PRODUCT APPROVAL FOR ENTRY
 DOOR WITH SIDELITE ASSEMBLY.
 7-UPDATE/REVISE ORIGINAL DRAWINGS. SEE
 COMMENTS ON DRAWINGS, INCLUDING THE
 COVER SHEET.