| Date |
Text |
| 2001-01-08 00:00:00 | APPROVED WITH PROVISO: |
| | 1-PROVIDE COMPLETE DETAIL AND SPECS FOR |
| | INSTALLATION OF WINDOWS TO THE STEEL |
| | COLUMN AT BREAKFAST AREA. (SPECS TO BE |
| | CONSISTENT WITH WINDOWS PRODUCT |
| | APPROVAL). |
| | 2-UPDATE/REVISE ALL PLANS AS REQUIRED. |
| | SEE COMMENTS ON PLANS. |
| | 3-STORM PANELS: |
| | -PROVIDE A COMPLETE INSTALLATION SCHED. |
| | AS PER CITY SAMPLE ATTACHED. |
| | -CLEARLY IDENTIFY FASTENING METHOD AND |
| | ANCHORS AND SPACING TO BE USED. |
| | -CLEARLY IDENTIFY STORM PANELS THAT ARE |
| | GOING TO BE ATTACHED TO CONCRETE, WOOD |
| | OR MASONRY. |
| | -CLEARLY MARK THE ANCHOR SCHEDULE ON |
| | PAGE 5 OF 6 OF PRODUCT APPROVAL. |
| | -SEE DESIGN PRESSURES CALCULATED BY |
| | ARCHITECT AND REVISE HIGHLIGHT MARKED |
| | ON TABLE 4, DRAWING 4 OF 6 PRODUCT APP |
| | 4-DESIGN CERTIFICATION FOR BUILDING CODE |
| | COMPLIANCE FORM: |
| | -IF THE STRUCTURAL ENGINEER OF RECORD |
| | IS ROBERT E. AGSTEN III, P.E., THEN HE |
| | NEEDS TO SIGN, SEAL AND DATE THE |
| | STRUCTURAL DRAWINGS AS WELL. |
| | 5-SLIDING GLASS DOORS WITH TRANSOM ABOVE |
| | DRAWINGS NEED TO BE SITE SPECIFIC. |
| | COMPLETE ADDRESS TO BE CLEARLY WRITTEN |
| | ON ORIGINAL DRAWING BY THE ENGINEER |
| | (NOT BY HAND). |
| | -THIS DRAWING TO BE ACCOMPANIED WITH |
| | THE PRODUCT APPROVAL SUBMITTAL FORM |
| | ATTACHED AND NEED TO BE SIGNED, SEALED |
| | AND DATED BY THE DESIGN PROFESSIONAL |
| | OF RECORD TOO. (SPECIFIC ADDRESS TO BE |
| | CLEARLY WRITTEN BY THE DESIGNER OF |
| | RECORD). |
| | 6-CLARIFY HOW IS STORM PANELS NUMBER 13 |
| | AND 14 ATTACHED TO THE STEEL COLUMN. |
| | (INSTALLATION SCHEDULE SAYS IT IS TO |
| | BE INSTALLED HORIZONTALLY). |
| | 7-PRODUCT APPROVAL FOR ENTRY DOORS IS |
| | FOR OUTSWING DOORS. ARCHITECT'S |
| | DRAWINGS SHOWS INSWING DOORS. RESUBMIT |
| | 8-TRUSS DRAWINGS: |
| | -MEAN ROOF HEIGHT IS 18'-3" PLUS OR |
| | MINUS. NOT 16'-0". SEE ELEVATIONS. |
| | NOTE: MEAN ROOF HEIGHT IS TAKEN FROM |
| | GRADE, NOT FROM FINISH FLOOR, TO THE |
| | AVERAGE POINT OF THE HIGHEST ROOF. |
| | -UPDATE AND SIGN, SEAL AND DATE ALL |
| | GENERAL DETAILS. THEY SHOULD BE |
| | UPDATED FOR SBC 1997 AS STATED ON THE |
| | ENGINEERED TRUSSES. |