2001-01-08 00:00:00*************PROVISO********************
  
 1]BROWARD COUNTY REPORT FOR EXT. DOOR
 MUST BE SIGNED AND SEALED BY ARCH. OF
 RECORD TO BE EXCEPTABLE.
 2]GLASS BLOCK MUST BE 1HR CONSTRUCTION,
 SUBMIT SPECIFICATIONS.
 3]SECTION 1804.1.3,1997 SBC REQUIRES THE
 BOTTOM OF THE FOOTERS TO BE 12" BELOW
 FINISH GRADE,ALSO SEE 1804.6.1.3.
 4]SECTION 2306.1 REQUIRES 4"SPACING IN
 ZONE 3 ON PAGE A-6 [FOR THE ROOF
 SHEATHING].
 5]FIXED WINDOWS AT REAR ELEVATION ARE
 NOT IN COMPLIANCE WITH ELEVEN FOOT
 SPAN.SUBMIT NEW PRODUCT REPORT OR
 REVISE OPENINGS TO COMPLY.
 6]SUBMIT INSTALLATION SCHEDULE AND SPEC.
 OUT ANCHORS TO BE USED FOR STORM
 PANELS.