Plan Review Notes
Plan Review Notes For Permit 00010370
Permit Number 00010370
Review Stop P
Sequence Number 1
Notes
Date Text
2001-01-08 00:00:00PLUMBING PLAN REVIEW# 102
 DENIED
 (1) SHT-2 BOTTLED WATER DISPENSER NOT
 PERMITED IN LEIU OF DRINKING FOUNTAIN,
 ALSO TO COMPLY WITH ADA ACCESSIBLE
 FACBC 4.1.3 (10)(A), SPC TAB 407.
 (2) FLOOR DRAINS REQUIRED WITH TRAP
 PRIMERS IN REST RMS SEC 409.4 EXCEPTION.
 (3)INFORMATION ON WASTE FROM PROCESSOR
 FOR PH LEVEL.
 (4) ALL EQUIPMENT CONNECTED TO THE WATER
 SULLLY TO BE PROTECTED WITH A APPROVED
 BACK FLOW PREVENTER.
 (5) BREAK ROOM SINK TO BE ADA ACCESSIBLE
 34" HIGH COUNTER TOP. 4.24 TO4.24.7
 FACBCEND OF COMMENTS