| Plan Review Stops For Permit 99122120 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-08-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-08-08 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-08-08 |
Time |
12:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-02-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-02-01 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-02-01 |
Time |
14:00 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************** UNSAT **************** | | | | | | 1)NOTE: NEED TO SUBMIT AIC RATING OF | | | EQUIPMENTMAINS. RATING NEEDS TO BE | | | ABLE TO HANDLE AVAILABLE FAULT CURRENT. | | | 110-9/230-65 | | | | | | 2))NOTE:SHOW DISCONNECTS REQ`D FOR A/C | | | PER 440-11 | | | | | | 3)NOTE: MASTER BEDROOM NEEDS TO HAVE | | | MEANS OF EGRESS LIGHTING AS PER 210-70A | | | AN ALSO FROM FAMILY ROOM GOING OUTSDIE. | | | | | | 4)NOTE:NEED TO CHECK FOR KITCHEN PENIN- | | | SULAR REQ`D RECEPT.PER 210-52-C | | | | | | 5)NOTE: ALL OUTLETS SERVING KITCHEN | | | COUNTERSPACE ARE TO BE GFI/GFI PROTECT- | | | ED. AS PER 210-8-A-6 | | | | | | 6)NOTE: NEED TO LABEL ALL OUTLETS THAT | | | ARE REQ`D TO BE GFI/ GFI PROTECTED. | | | GARAGE,OUTSIDE,BATHS AS PER 210-8 | | | | | | 7)NOTE: YOU SHOW EQUIPMENT GROUNDING | | | CONDUCTOR BEING INSTALLED FROM METER | | | TO PANELS?? ONLY AFTER FIRST MEANS | | | OF DISC. | | | | | | 8)NOTE:NOTE MISSING RECEPTS AS REQ`D BY | | | 210-52 2`6`12` RULE. | | | | | | 9)NOTE:SMOKE DETECTORS INSTALLED INSIDE | | | AND OUTSIDE ALL SLEEPING ROOMS AS REQ`D | | | BY 1993/1996 NFPA-72 2-2.1.1.1 | | | | | | 10)NOTE: NEED TO HAVE COLD WATER PIPE, | | | AND BLDG. STEEL AS PART OF THE GROUNDING | | | ELECTRODE SYSTEM. AS PER 250-81 | | | PLEASE SHOW ON RISER DIAGRAM 215-5 | | | | | | 11)NOTE:PLEASE SHOW ON PANEL SCHEDULES | | | THE REQ`D BATH(S) CIRCUT(S) AS PER ART | | | 210-52D. NEED TO BE 20AMP #12 AWG. | | | | | | 12)NOTE PLEASE INDICATE WHEATER OR NOT | | | MAIN CIRCUT BRKR. PANELS OR NOT.215-5 | | | | | | NEED TO SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW AND APPROVAL. IF THERE ARE | | | ANY QUESTIONS PLEASE CALL 659-8096 | | | EXT. 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2000-08-04 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-08-04 |
Time |
09:59 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-08-04 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO: | | | PROVISO ADDITIONAL INFORMATION ON THE | | | EXHAUST FANS IN BATHROOMS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2000-01-22 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-01-22 |
Time |
10:40 |
Rev Time |
0.35 |
| Received By |
jleech |
Date |
2000-01-22 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NOTE; | | | NO A/C DRAWING. | | | A/C DRAWING TO BE SUBMITED BY A/C | | | CONTRACTOR WITH APPLICATION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2001-05-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-05-07 |
Time |
13:31 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2001-05-07 |
Time |
13:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2000-01-07 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-01-07 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
tlarge |
Date |
2000-01-07 |
Time |
13:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-01-06 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-01-06 |
Time |
05:51 |
Rev Time |
0.33 |
| Received By |
tlarge |
Date |
2000-01-06 |
Time |
05:51 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SUBMIT SANITARY ISOMETRIC FOR REVIEW. | | | COUNTYWIDE AMENDMENTS TO SPC SEC.104.2.1 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2000-09-25 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-09-25 |
Time |
14:21 |
Rev Time |
4.00 |
| Received By |
fknapp |
Date |
2000-09-22 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | | | | | | | *************BUILDING PROVISO*********** | | | | | | SBC 104.2.2 | | | | | | 1)PROVIDE PRODUCT APPROVAL FOR ROOF | | | COVERING UNDER SEPARATE PERMIT. | | | | | | 2)PROVIDE STORM PANEL INFORMATION FOR | | | ALL NON IMPACT RESISTANT GLASS UNDER | | | SEPARATE PERMIT. | | | | | | PLEASE SUBMIT PRIOR TO INSTALLATION |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2000-08-29 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-08-29 |
Time |
14:18 |
Rev Time |
2.00 |
| Received By |
fknapp |
Date |
2000-08-29 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SEE PREVIOUS REVIEW NOTES |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2000-08-09 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-08-09 |
Time |
13:32 |
Rev Time |
2.00 |
| Received By |
fknapp |
Date |
2000-08-09 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | | | | | | | **********BUILDING DENIED************** | | | | | | SEE ORIGINAL NOTES FROM FIRST REVIEW |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2000-02-17 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-02-17 |
Time |
15:14 |
Rev Time |
4.00 |
| Received By |
fknapp |
Date |
2000-02-17 |
Time |
15:14 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | *****************DENIED***************** | | | | | | SBC 104.2.2 | | | | | | 1)PROVIDE RAISE SEAL AND ORIGINAL | | | SIGNATURE OF ARCHITECT ON ALL SHEETS OF | | | PLANS. | | | | | | 2)PROVIDE SOIL REPORT. | | | | | | 3)PROVIDE 2 CURRENT COPIES OF PRODUCT | | | APPROVALS FOR: | | | ROOF COVERING | | | EXTERIOR DOORS,WINDOWS AND MULLIONS | | | GARAGE DOOR | | | STORM PANELS WITH INSTALLATION | | | SCHEDULE AND KEY PLAN WITH SPECIFIC | | | ANCHORS TO BE USED. | | | | | | 4)PROVIDE ENERGY CALCULATIONS WITH | | | MANUEL J. | | | | | | 5)PROVIDE ROOF FRAMING PLAN WITH UPLIFT | | | CALCULATIONS AND ANCHOR SCHEDULE SBC1606 | | | | | | 6)PROVIDE FLOOR FRAMING PLAN SBC 1606 | | | | | | 7)PROVIDE CURRENT DESIGN COMPLIANCE FORM | | | | | | 8)PROVIDE ROOF SHEATING NAILING ZONES | | | COMPLYING WITH CITY AMENDMENTS 2306.1 | | | AND SBC 1606 | | | | | | 9)PROVIDE SPECIFIC WINDOW AND DOOR BUCK | | | CONNECTIONS FOR WINDLOAD RESISTANCE | | | SBC 1606 | | | | | | 10)PROVIDE STAIR SECTION,TREAD,RISER | | | DIMENSIONS,HANDRAIL,GUARDRAIL SBC 1006, | | | 1007 AND 1015 | | | | | | 11)PROVIDE MECHANICAL DRAWINGS WITH | | | PERMIT APPLICATION. | | | | | | 12)BEFORE A PERMIT TO CONSTRUCT CAN BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH CO.,THE PLANS STAMPED BY THEM AND | | | THE RECIEPT ATTACHED TO PERMIT | | | APPLICATION. |
|
|