| 2001-01-08 00:00:00 | SUBMIT DETAIL OF REINFORCEMENT OF WALLS |
| | FOR FUTURE INSTALLATION OF GRAB BARS AS |
| | REQUIRED BY THE FEDERAL FAIR HOUSING ACT |
| | 24 CFR 100.205 SEC.3 REQUIREMENT #6. |
| | NOTE:ALL BATHROOMS WITHIN THE COVERED |
| | DWELLING UNIT SHALL COMPLY. |
| | |
| | ALL BATHROOMS IN THE COVERED DWELLING |
| | UNIT SHALL COMPLY W/THE PROVISIONS OF |
| | THE FEDERAL FAIR HOUSING ACT 24 CFR |
| | 100.205 (C)(3)(IV) REQUIREMENT #7 (2) |
| | PARAGRAPH (A)OR(B).CLEAR FLOOR SPACE |
| | SHALL BE PROVIDED AT FIXTURES TO ALLOW A |
| | PERSON IN A WHEELCHAIR OR OTHER MOBILITY |
| | AID USE OF THE FIXTURES.CLEAR FLOOR |
| | SPACE SHALL BE SHOWN ON THE PLANS AND |
| | DESIGNATE WHICH OPTION OF REQUIREMENT#7 |
| | (A OR B) IS BEING USED. |
| | |
| | LAUNDRY ROOMS SHALL COMPLY W/ANSI A117.1 |
| | 1986 SEC.4.32.1-4.32.6.3. |
| | |
| | ALL TOILET ROOMS AND BATHING FACILITIES |
| | IN ALL PUBLIC AND COMMON AREAS SHALL BE |
| | ACCESSIBLE PER ANSI A117.1 1986 SEC. |
| | 4.22.1-4.22.4. |
| | |
| | SUBMIT SQUARE FOOTAGE OF REC.BUILDING |
| | AND OCCUPANT LOAD TO ENSURE COMPLIANCE |
| | W/SPC TABLE 407. |
| | |
| | SHT.A-4.2.1.-HANDICAP STALLS ARE UNDER- |
| | SIZED.COMPLY W/FACBC SEC.4.17.3 |
| | EXCEPTION:NEW CONSTRUCTION. |
| | |
| | SHOW CLEAR FLOOR SPACE AT URINAL AND |
| | HEIGHT OF URINAL.COMPLY W/FACBC SEC. |
| | 4.18.1 THRU 4.18.4. |
| | |
| | SUBMIT DETAILS/MOUNTING HEIGHTS OF ALL |
| | PLUMBING FIXTURES/APPURTENANCES.COMPLY |
| | W/FACBC AND SPC 403.4. |
| | |
| | SHT.P-1-CLEANOUTS SHALL BE INSTALLED |
| | IN BUILDING DRAIN AND COMPLY W/SPC SEC. |
| | 710.2.4. |
| | |
| | SUBMIT RISER DIAGRAM FOR COMPLETE STORM |
| | WATER SYSTEM.SUBMIT DETAILS/CALCULATIONS |
| | FOR SECONDARY DRAINAGE PER SPC 1109.1, |
| | 1109.2,APPENDIX"A"& TABLE A101.2. |
| | |
| | DETAIL THE TYPE OF OPERATIONS TO BE |
| | CONDUCTED IN THE KITCHEN.IF FOOD WILL BE |
| | COOKED A GREASE INTERCEPTOR WILL BE REQD |
| | PER SPC 1OO4.1.SUBMIT DETAIL OF GREASE |
| | TRAP.SPC 1004.2. |
| | |
| | SIZE THE UNDERGROUND SANITARY SYSTEM |
| | IN ITS ENTIRETY.COMPLY W/SPC SEC.714.1, |
| | 714.2. |
| | |
| | SIZE THE WATER RISERS ON SHT.P-8.COMPLY |
| | W/SPC SEC.607.1,APPENDIX"F". |
| | |
| | WATER SUPPLY BRANCHES TO KIT.SINKS SHALL |
| | BE VALVED PER SPC SEC.610.4.1. |
| | |
| | SHT.P-9-VERTICAL COMBINATION WASTE AND |
| | VENT SYSTEM FOR KIT.SINK.SHALL COMPLY W/ |
| | SPC SEC.911.4.AND TABLE 911.4.(SEE |
| | RISERS S2,S3,S5,S6,S7,S9. |
| | |
| | SANITARY RISERS S1,S4,S5,S8-SHALL COMPLY |
| | W/SPC SEC.911.3.(SIZE OF LOWEST WET VENT |
| | |
| | P & T DRAINS SHALL COMPLY W/COUNTYWIDE |
| | AMENDMENTS TO SPC SEC.507.6(3). |
| | (DISCHARGE TO EXTERIOR). |
| | |
| | CLARIFY TYPE OF DRAINS FOR WASHING |
| | MACHINES.DESIGN IS UNFAMILIAR AND DOES |
| | NOT APPEAR TO COMPLY W/SPC. |