Plan Review Details - Permit 99121922
Plan Review Stops For Permit 99121922
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-08-02 Cont ID  
Sent By dpalmer Date 2000-08-02 Time 17:38 Rev Time 0.00
Received By dpalmer Date 2000-08-02 Time 17:38 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-01-25 Cont ID  
Sent By jleech Date 2001-01-25 Time 19:00 Rev Time 0.33
Received By jleech Date 2001-01-25 Time 19:00 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-08-08 Cont ID  
Sent By cthirben Date 2000-08-08 Time 09:51 Rev Time 1.00
Received By cthirben Date 2000-08-08 Time 09:47 Sent To  
Notes
2001-01-08 00:00:00PROVISO:
 * PROVIDE A/C SUPPLY AIR TO THE NOOK.
 *REQUIRES AN EXHAUST FAN IN THE 1ST
 FLOOR AS PER 1997 SMC 503.3.1....

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-08-02 Cont ID  
Sent By tlarge Date 2000-08-02 Time 06:33 Rev Time 0.33
Received By tlarge Date 2000-08-02 Time 06:21 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 6 Status P Date 2001-01-19 Cont ID  
Sent By jgomez Date 2001-01-19 Time 16:53 Rev Time 0.25
Received By jgomez Date 2001-01-19 Time 16:53 Sent To  
Notes
2001-01-19 00:00:00TRUSS DRAWINGS APPROVED.

Review Stop R ROOF PLAN REVIEW
Rev No 5 Status F Date 2001-01-12 Cont ID  
Sent By jgomez Date 2001-01-12 Time 08:42 Rev Time 0.50
Received By jgomez Date 2001-01-11 Time 18:43 Sent To  
Notes
2001-01-11 00:00:00TRUSS DRAWINGS CHECKLIST:
 1-WHERE IS THE ENGINEERING FOR THE
 PARALAM BEAM?.
 2-TRUSS DRAWINGS GENERAL DETAILS AND
 SPECIFICATIONS PACKAGE NEED TO BE
 COORDINATED AND UPDATED. THERE ARE
 DETAILS ANDSPECIFICATIONS THAT ARE
 TOO OLD AND REFERENCING OLD CODES.
 -ENGINEER IS SIGNING AND SEALING
 DOCUMENTS THAT HAVE THE NAME OF
 ANOTHER ENGINEER.
 -ENGINEER TO FOLLOW ALL REQUIREMENTS
 OF CHAPTER 471 FLORIDA STATUTES WHEN
 SUBMITTING DOCUMENTS FOR PUBLIC RECORD
 3-SUPPORT REPORT INDICATES THAT TRUSSES
 WERE DESIGNED USING SBC 1991. CITY HAS
 ADOPTED SBC 1997.

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status F Date 2000-12-04 Cont ID  
Sent By jgomez Date 2000-12-04 Time 14:19 Rev Time 1.00
Received By jgomez Date   Time   Sent To  
Notes
2001-01-08 00:00:00TRUSSES CHECKLIST:
 1-WHERE IS THE ENGINEERING FOR THE
 PARALAM BEAM?
 2-DESIGN CRITERIA SHALL BE SPECIFIC:
 SBCCI IS NOT THE BUILDING CODE. IT IS
 THE ENTITY WHO PUBLISHES IT.
 THE ACTUAL BUILDING CODE IS THE SBC
 1997 (STANDARD BUILDING CODE, 1997).
 3-THERE SHALL BE ONLY ONE MEAN ROOF
 HEIGHT FOR ENTIRE BUILDING. REVISE
 ENGINEERED TRUSS DRAWINGS AS REQUIRED.
 TABLE 1606.2A SBC 1997.
  
  
  
  
  
 NOTES:
 -IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 659-8096 EXT. 8232.
 -REMAINDER: PLEASE HAVE YOUR ENGINEER
 REVIEW ALL TRUSS DRAWINGS PRIOR TO
 SUBMITTAL TO THIS OFFICE.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2000-08-23 Cont ID  
Sent By jgomez Date 2000-08-23 Time 19:10 Rev Time 2.50
Received By jgomez Date 2000-08-23 Time 19:10 Sent To  
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE A8. NEED TO PROVIDE
 ELEVATION CERTIFICATE.
 2-ENERGY CALCULATIONS NEED TO BE REVISED
 SHOWING THE ACTUAL CONDITIONED FLOOR
 AREA (2749 S.F.). THIS CAN'T BE DONE
 MANUALLY. IT'S A COMPUTER PROGRAM.
 3-AREA CALCULATIONS TO BE REVISED IN
 ORIGINAL DRAWING BY THE ENGINEER OF
 RECORD. HE'S THE ONE RESPONSIBLE TO DO
 ANY CHANGES IN HIS DRAWINGS.
 4-PROVIDE COPIES OF NORANDEX SLIDING
 GLASS DOORS SHOWING TESTS RESULTS DONE
 AS PER ASTM E-330.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2000-08-08 Cont ID  
Sent By rmcdouga Date 2000-08-08 Time 07:21 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00DENIED
  
 1)FLOOD ELEVATION CERTIFICATE WILL BE
 REQUIRED.
  
 2)ADDITIONAL IMPACT FEES ARE DUE TO THE
 COUNTY FOR ADDITIONAL 397 SQFT UNDER A/C
 FOR OPTIONAL LOFT AND NOOK OFF KITCHEN.
  
 3)SUBMIT 2 COPIES OF REVISED STORM PANEL
 KEY PLAN AND SCHEDULE THAT CORRESPONDS
 WITH SPECIFIC OPTIONS TO BE USED.
  
 4)SPECIFICATIONS FOR GARAGE DOOR
 SUBMITTED WITH PRODUCT APPROVAL INDICATE
 A NEGATIVE DESIGN PRESSURE OF -33PSF FOR
 A 16'X7' DOOR ,WIND LOADS ON SHEET A-4A
 LISTS NEG. PRESSURE OF -34PSF.
 PLEASE CORRECT.
  
 5)PROVIDE 2 CURRENT COPIES OF METRO-DADE
 OR SBCCI PRODUCT APPROVALS FOR EXTERIOR
 OUTSWING STEEL DOOR WITH SIDE LITES AS
 SHOWN ON PLANS.PRODUCT APPROVALS ARE
 REQUIRED FOR SPECIFIC ITEM THAT WILL BE
 INSTALLED.
  
 6)THE VALUES LISTED IN THE WIND PRESSURE
 SCHEDULE ON SHEET A-4A DO NOT AGREE WITH
 THE PRESSURES LISTED ON THE DRAWING FOR
 WINDOWS J,S & T. PLEASE CORRECT.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-06-20 Cont ID  
Sent By lsmith Date 2000-06-20 Time 15:35 Rev Time 0.50
Received By lsmith Date   Time   Sent To  
Notes
2001-01-08 00:00:00FAILED PER TM 6/19/00

Review Stop Z ZONING
Rev No 1 Status P Date 2000-08-08 Cont ID  
Sent By gjoyce Date 2000-02-16 Time 12:18 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***