Plan Review Details - Permit 99121739
| Plan Review Stops For Permit 99121739 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2000-03-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-03-31 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-03-31 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ***************PROVISO ***************** | | | | | | 1)NOTE: STILL SHOWING MAIN ON RISER BUT | | | NOT ON PLANS????? | | | | | | 2)NOTE: BATH DEDICATED CIRCUT IS NOT | | | SHOWN ON PANEL SCHEDULE. | | | | | | 3)NOTE: AS PER 210-8-A-6 ALL OUTLETS | | | SERVING KITCHEN COUNTER SPACE ARE TO BE | | | GFI/GFI PROTECTED!! PLEASE INDICATE ON | | | PLANS,,,,ALL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-02-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-02-24 |
Time |
07:10 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-02-24 |
Time |
07:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-01-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-01-22 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-01-22 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ************* UNSAT ******************* | | | | | | THESE ARE NOTES THAT WERE ALREADY GIVEN | | | AT OTHER TIMES. | | | | | | 1)NOTE: PLEASE SUBMIT AIC RATING OF | | | EQUIPMENT MAINS!! AND OR PANELS. | | | AIC RATING IS FIGURED FROM FAULT CURRENT | | | CALCULATIONS. REQ`D BY ARTS;230-65.110-9 | | | AND 215-5 | | | | | | 2)NOTE;AS PER NFPA-72 2-2.1.1.1 SMOKE | | | DETECTORS ARE REQ`D INSIDE AND OUTSIDE | | | ALL SLEEPING ROOMS. PLEASE CORRECT. | | | | | | 3)NOTE: AS REQ`D BY ART;210-8-A-6 ALL | | | OUTLETS SERVING KITCHEN COUNTERSPACE | | | ARE TO BE GFI/GFI PROTECTED. ALL NEED TO | | | BE LABELED THAT WAY. | | | | | | 4)NOTE:PLEASE CORRECT OPTIONAL KITCHEN | | | PLAN. | | | | | | 5)NOTE:PLANS DON`T SHOW MAIN DISC.ON THE | | | SIDE OF THE HOUSE. WHICH IS CORRECT? | | | PLAN OR RISER DIAGRAM? | | | | | | 6)NOTE: AS REQ`D BY 250-81/215-5 | | | PLEASE SHOW BLDG.STEEL AS THE OTHER | | | METHOD OF GROUNDING ELECTRODE CONDUCTOR. | | | | | | 7)NOTE:AS REQ`D BY 210-52D/215-5 PLEASE | | | HAVE LISTED ON PANEL SCHEDULE THE DED- | | | -ICATED BATH(S) CIRCUT(S) REQ`D TO BE | | | 20AMP AND #12 AWG. | | | | | | PLEASE HAVE ALL THE ABOVE INFORMATION | | | CORRECTED AND SUBMITTED FOR REVIEW AND | | | APPROVAL. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL 659-8096 EXT 8372. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-02-24 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-01-18 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
bstaples |
Date |
2000-02-24 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ************PROVISO******************* | | | 1. 4 TON UNIT IS NOT CAPABLE OF | | | PROVIDING 1740 CFM. REVISE DRAWINGS. | | | 2. ELECTRIC EXHAUST FAN IS REQUIRED IN | | | MASTER TOILET ROOM. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-01-04 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-01-04 |
Time |
19:15 |
Rev Time |
0.33 |
| Received By |
tlarge |
Date |
2000-01-04 |
Time |
19:15 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************PROVISO******************* | | | SANITARY RISER DOESN'T MATCH FLOOR PLAN. | | | SUBMIT REVISED RISER PRIOR TO RGH.PLBG. | | | INSP. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2000-02-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2000-02-25 |
Time |
13:08 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2000-02-25 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | APPROVED WITH PROVISO: | | | 1-FLOOD ZONE A8. PROVIDE ELEVATION | | | CERTIFICATE. | | | 2-SEE COMMENTS ON PLANS AND REVISE/ | | | UPDATE AS REQUIRED. | | | 3-SEE PROVISOS BY OTHER TRADES. | | | 4-RE-SUBMIT GARAGE DOOR PRODUCT APPROVAL | | | DRAWINGS DON'T MATCH PRODUCT APPROVAL. | | | WHY FINAL PRODUCT APPROVAL BY SBCCI | | | DOESN'T HAVE A NUMBER ASSIGNED? | | | 5-STORM PANELS: | | | -INSTALLATION SCHEDULE AND KEY PLAN | | | DON'T MATCH PLANS. REVISE AS REQUIRED | | | AND COMPLETE ALL THE INFORMATION AS | | | REQUESTED ON CITY SAMPLE FOR | | | INSTALLATION SCHEDULE ATTACHED. | | | -SEE NOTE #4 ON SHEET 3 OF 5 OF STORM | | | PANELS DRAWINGS. INSTALLATION SCHED. | | | CALLS FOR A 33" STORM PANEL AND THIS | | | NOTE LIMITS THE STORM PANELS TO 40" | | | REVISE AS REQUIRED. | | | 6-ENTRY DOOR: | | | -CLEARLY SPECIFY FASTENERS TO BE USED | | | ACCORDING TO THE PRODUCT APPROVAL AND | | | FRAME DETAIL SPECIFIED BY ENGINEER ON | | | SHEET A-6. | | | -DRAWINGS IN PRODUCT APPROVAL ARE NOT | | | CLEAR OR IMCOMPLETE. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2000-02-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2000-01-29 |
Time |
16:12 |
Rev Time |
2.50 |
| Received By |
jgomez |
Date |
2000-01-29 |
Time |
16:12 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | CHECKLIST: | | | 1-PAY IMPACT FEES. | | | 2-UPDATE/REVISE ALL DRAWINGS. SEE | | | COMMENTS ON PLANS. | | | 3-FOOTING F2 TO BE 16" DEEP MIN. | | | SEC 1804.1.3 SBC 1997. | | | 4-REVISE ELEVATIONS TO MATCH FLOOR PLAN. | | | 5-REVISE SURVEY. THIS PROPERTY IS ON | | | FLOOD ZONE "A8' NOT FLOOD ZONE B. | | | 6-PROVIDE COMPLETE BUCK DETAILS FOR | | | EXTERIOR DOORS, WINDOWS AND GARAGE | | | DOOR. | | | 7-REVISE ENERGY CALCULATIONS. SOUTH IS | | | THE REGION NOT THE CLIMATE ZONE. THE | | | CLIMATE ZONE IS #8. | | | 8-PROVIDE PRODUCT APPROVAL FOR ENTRY | | | DOOR WITH SIDELITES ASSEMBLY. | | | 9-GARAGE DOOR PRODUCT APPROVAL: | | | -THERE IS NO A LISTING FOR THIS DOORS | | | WITH SBCCI. | | | -DESIGN PRESSURES DON'T MEET THE DESIGN | | | PRESSURES CALCULATED BY THE ENGINEER | | | -DRAWINGS DON'T MATCH REPORT. | | | 10-PROVIDE COMPLETE INFORMATION FOR | | | STORM PANELS (OR INFORMATION MAY BE | | | SUBMITTED LATER UNDER A SEPARATE | | | PERMIT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
1999-12-30 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
1999-12-30 |
Time |
11:15 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|