| Plan Review Stops For Permit 99121632 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2001-01-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-01-16 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-01-16 |
Time |
16:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2000-11-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-11-14 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-11-14 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************** UNSAT ***************** | | | | | | 1)NOTE: PLEASE SEE NOTES FROM FIRST RE- | | | -VIEW. NOT ALL NOTES WERE ADDRESSED. | | | | | | 2)NOTE: PLEASE SEE PANEL SCHEDULE,PLEASE | | | LIST THE REQ`D BATH(S) CIRCUIT(S) PER | | | 210-11-C-3. #12, 20A. | | | | | | 3)NOTE: PLEASE SEE 384-15. PANELS ARE | | | NOT PERMITTED TO HAVE MORETHAN 42 SPACES | | | | | | 4)NOTE: PLEASE SEE 210-8-A-6.ALL OUTLETS | | | SERVING KITCHEN COUNTERSPACE ARE TO GFI/ | | | GFI PROTECTED. PLEASE SHOW AND PLEASE | | | SHOW ON KITCHEN OPT PLAN ALSO. | | | | | | 5)NOTE: PLEASE SEE 210-52H FOR OUTLET | | | REQ`D IN MASTER BEDROOM HALLWAY. | | | | | | 6)NOTE: PLEASE SHOW THE MAIN DISCONNECT | | | ON THE PLAN AS IT IS SHOWN ON THE RISER | | | DIAGRAM. 215-5 | | | | | | 7)NOTE: PLEASE SUBMIT SUBMIT CLARIFICAT- | | | ION ON THE "DOUBLE TUB" WRIITEN ON RISER | | | AND PANEL SCHEDULE?? | | | | | | | | | PLEASE MAKE THE ABOVE CHANGES AND SUBMIT | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-02-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-02-05 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-02-05 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************** UNSAT ****************** | | | | | | 1)NOTE: PLEASE SHOW THE AIC RATING OF | | | EQUIPMENT MAINS. MAINS ARE TO BE RATED | | | FOR THE AVAILABLE FAULT CURRENT. AS REQ` | | | -D BY ARTS: 110-9/110-10/215-5 OF THE | | | NEC. PLEASE SHOW ON PLANS/ | | | | | | 2)NOTE:PLEASE CORRECT THE OPTIONAL | | | KITCHEN PLAN. | | | | | | 3)NOTE: RISER DIAGRAM SHOW MAIN DISC. | | | PLEASE DRAW ON PLANS NEXT TO METERCAN. | | | | | | 4)NOTE: SHOW THE OTHER GROUND AS BEING | | | BLDG.STEEL. | | | | | | 5)NOTE:AS REQ`D BY 210-52H NEED TO HAVE | | | OUTLET IN THE MASTER BEDROOM HALL.10` | | | OR MORE. | | | | | | 6)NOTE:AS REQ`D BY NFPA-72 2-2.1.1.1 | | | SMOKE DETECTORS ARE REQ`D INSIDE AND | | | OUTSIDE ALL SLEEPING ROOMS. | | | | | | 7)NOTE: PLEASE SHOW ALL OUTLETS SERVING | | | KITCHEN COUNTERSPACE AS GFI/GFI PROTECT- | | | -ED. AS REQ`D BY 210-8-A-6 | | | | | | | | | PLEASE HAVE ALL THE ABOVE INFORMATION | | | SUBMITTED FOR REVIEW AND APPROVAL. | | | IF THERE ARE ANY QUESTIONS PLEASE CALL | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-02-05 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-02-05 |
Time |
07:35 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2000-02-05 |
Time |
07:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-01-28 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-01-28 |
Time |
18:03 |
Rev Time |
0.33 |
| Received By |
tlarge |
Date |
2000-01-28 |
Time |
18:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
F |
Date |
2001-02-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-02-14 |
Time |
10:41 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2001-02-14 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2001-02-14 00:00:00 | TRUSS DRAWINGS CHECKLIST: | | | | | | 1-UNABLE TO IDENTIFY ENGINEER. | | | -ENGINEERS SHALL LEGIBLY INDICATE THEIR | | | NAME ADDRESS AND NUMBER ON EACH SHEET | | | AS REQUIRED BY CHAPTER 471 FLORIDA | | | STATUTES. | | | | | | | | | | | | | | | | | | | | | BUILDING PLAN REVIEWER: JULIO GOMEZ AT | | | 659-8096 EXT. 8232. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2001-01-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-01-19 |
Time |
16:27 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2001-01-19 |
Time |
16:27 |
Sent To |
|
|
| Notes |
| 2001-01-19 00:00:00 | APPROVED WITH PROVISO: | | | | | | 1-UPDATE ALL PLANS AS REQUIRED. SEE | | | COMMENTS ON PLANS. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2000-11-30 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2000-11-30 |
Time |
13:53 |
Rev Time |
1.50 |
| Received By |
jgomez |
Date |
2000-11-30 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | CHECKLIST: | | | 1-SURVEY DOESN'T MATCH THE LAGUNA MODEL. | | | 2-REVISE ENERGY CALCULATIONS: | | | -NEED THE LAGUNA MODEL | | | -NEED ORIGINAL SIGNATURE AND DATE OF | | | PERSON WHO PREPARED THE ENERGY CALCS. | | | 3-REVISE/UPDATE ALL DRAWINGS AS REQUIRED | | | SEE NOTES ON REVIEWED SET. | | | 4-SEE COMMENTSBY ELECTRICAL PLAN | | | REVIEWER. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2000-06-20 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2000-06-20 |
Time |
10:03 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SEE NOTES PER TM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-06-19 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-06-19 |
Time |
16:35 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|