Plan Review Details - Permit 99121626
Plan Review Stops For Permit 99121626
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-10-24 Cont ID  
Sent By dpalmer Date 2000-10-24 Time 18:13 Rev Time 0.00
Received By dpalmer Date 2000-10-24 Time 18:06 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-10-14 Cont ID  
Sent By jleech Date 2000-10-14 Time 12:23 Rev Time 0.50
Received By jleech Date 2000-10-14 Time 12:23 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-09-28 Cont ID  
Sent By tlarge Date 2000-09-28 Time 08:36 Rev Time 0.33
Received By tlarge Date 2000-09-28 Time 08:36 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2001-02-14 Cont ID  
Sent By jgomez Date 2001-02-14 Time 16:45 Rev Time 0.50
Received By jgomez Date 2001-02-14 Time 16:44 Sent To  
Notes
2001-02-14 00:00:00TRUSS DRAWINGS CHECKLIST:
 1-TRUSS DRAWINGS STILL SHOW THE WRONG
 MEAN ROOF HEIGHT. THIS IS A TWO STORY
 BUILDING. THE MEAN ROOF HEIGHT IS +/-
 22'-0". REVISE AS REQUIRED.
 2-SBC 1997 DOESN'T USE "WALL HEIGHT". IT
 USES THE MEAN ROOF HEIGHT OF THE
 BUILDING. REVISE ENGINEERED ROOF
 TRUSSES AS REQUIRED.
 3-CHECK IF CONNECTORS SPECIFIED WILL BE
 ADEQUATE TO SUPPORT THE LOADS AS
 CALCULATED ON THE REVISED ENGINEERED
 TRUSSES PRIOR TO SUBMITTAL TO THIS
 OFFICE.
 4-UNABLE TO IDENTIFY ENGINEER.
 -ENGINEERS SHALL LEGIBLY INDICATE THEIR
 NAME, ADDRESS, AND NUMBER ON EACH
 SHEET AS REQUIRED BY CHAPTER 471 OF
 FLORIDA STATUTES.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2000-10-21 Cont ID  
Sent By jgomez Date 2000-10-21 Time 15:18 Rev Time 2.50
Received By jgomez Date 2000-10-21 Time 15:18 Sent To  
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE "A8". PROVIDE ELEVATION
 CERTIFICATION.
 2-PROVIDE SIGNED AND SEALED SURVEY.
 3-PROVIDE THE DESIGN PRESSURES AT ALL
 EXTERIOR OPENINGS CALCULATED BY THE
 ENGINEER. SEC. 1606 SBC 1997.
 4-RESUBMIT ENERGY CALCULATIONS. ALL
 SIGNATURES TO BE ORIGINAL. NOT COPIES.
 SEC. 103.0 FLORIDA ENERGY EFFICIENCY
 CODE FOR BUILDING CONSTRUCTION,1997 ED
 5-PROVIDE PRODUCT APPROVAL FOR:
 -FLAT ROOF ROOF SYSTEM.
 -ENTRY DOOR. DOOR SHOWN ON PLAN IS AN
 INSWING DOOR, WHILE PRODUCT APPROVAL
 IS FOR AN OUTSWING DOOR. RE-SUBMIT.
 -GARAGE DOORS DRAWINGS ARE NOT LEGIBLE.
 ALSO, CHECK DESIGN PRESSURES AS
 CALCULATED BY THE ENGINEER.
 -PROVIDE COPIES OF TESTS DONE TO THE
 SLIDINGGLASS DOORS AS PER ASTM E-330
 STANDARDS. SECTION 1706 SBC 1997.
 6-SEE COMMENTS ON PLANS.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-06-20 Cont ID  
Sent By lsmith Date 2000-06-20 Time 10:07 Rev Time 0.50
Received By lsmith Date   Time   Sent To  
Notes
2001-01-08 00:00:00FAILED PER TM 6/19/00 SEE NOTES ON PLANS

Review Stop Z ZONING
Rev No 1 Status P Date 2000-02-10 Cont ID  
Sent By gjoyce Date 2000-02-10 Time 16:05 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***