Plan Review Details - Permit 99121450
Plan Review Stops For Permit 99121450
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-07-08 Cont ID  
Sent By dpalmer Date 2001-07-08 Time 10:41 Rev Time 0.00
Received By dpalmer Date 2001-07-08 Time 10:41 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-04-16 Cont ID  
Sent By dpalmer Date 2001-04-16 Time 21:18 Rev Time 0.00
Received By dpalmer Date 2001-04-16 Time 21:18 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2001-07-30 Cont ID  
Sent By pkrauss Date 2001-07-30 Time 12:51 Rev Time 0.40
Received By pkrauss Date 2001-07-30 Time 12:51 Sent To  
Notes
2001-07-30 00:00:00MECHANICAL PERMIT99121590

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2001-07-05 Cont ID  
Sent By pkrauss Date 2001-07-05 Time 11:47 Rev Time 0.30
Received By pkrauss Date 2001-07-05 Time 11:47 Sent To  
Notes
2001-07-05 00:00:00NO MECHANICAL WORK IS INDICATED ON PLAN.
  
 PLEASE PROVIDE REVISION FOR ANY
 MECHANICAL WORK BEING DONE.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT
 PATTY KRAUSS AT 659-8096 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-04-16 Cont ID  
Sent By jleech Date 2001-04-16 Time 20:02 Rev Time 0.33
Received By jleech Date 2001-04-16 Time 20:02 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2001-08-06 Cont ID  
Sent By kstevens Date 2001-08-06 Time 08:44 Rev Time 0.50
Received By kstevens Date 2001-08-06 Time 08:44 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-07-05 Cont ID  
Sent By kstevens Date 2001-07-05 Time 10:17 Rev Time 0.33
Received By kstevens Date 2001-07-05 Time 10:17 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-04-16 Cont ID  
Sent By kstevens Date 2001-04-16 Time 18:27 Rev Time 0.33
Received By kstevens Date 2001-04-16 Time 18:27 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 5 Status P Date 2001-08-13 Cont ID  
Sent By rmcdouga Date 2001-08-13 Time 13:17 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status F Date 2001-07-03 Cont ID  
Sent By rmcdouga Date 2001-07-03 Time 15:13 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-07-03 00:00:00*************BUILDING UNSAT*************
 REVISION
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) PROVIDE ENERGY CALCULATIONS AND
 MANUAL J CALCS FOR ADDITIONAL
 CONDITIONED SPACE AS REQUIRED BY FLORIDA
 ENERGY CODE.
  
 3) STRUCTURE IS LOCATED IN AN A8 FLOOD
 ZONE. THE FINISHED FLOOR ELEVATION OF
 ENCLOSED SPACE MUST COMPLY WITH CITY
 CODE.
  
 4) SHEET A-1B IS THE REVERSE OF THE
 OTHER TWO SHEETS SUBMITTED AND THE PLANS
 ON FILE. PLEASE SUBMIT SETS OF DRAWINGS
 WHICH ARE CONSISTENT WITH EACH OTHER.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2001-05-01 Cont ID  
Sent By rmcdouga Date 2001-05-01 Time 14:54 Rev Time 3.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2001-04-23 Cont ID  
Sent By rmcdouga Date 2001-04-23 Time 11:23 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-04-23 00:00:00*************BUILDING UNSAT*************
  
 1) STRUCTURE IS LOCATED IN AN "A8" FLOOD
 ZONE AN ELEVATION CERTIFICATE WILL BE
 REQUIRED PRIOR TO RECEIVING A C.O.
  
 2) THE TYPICAL EXTERIOR CEILING DETAIL
 ON SHEETS A-1 & A-1B IS FOR VERTICLE
 APPLICATION. SECTION 2504.2.2 OF THE
 1997 SBC REFERS TO ASTM C 1603, WHICH
 REQUIRES 1 3/4" PENETRATION INTO
 HORIZONTAL WOOD FRAMING MEMBERS FOR LATH
 ON CEILINGS. PLEASE CORRECT.
  
 3) THE MAXIMUM HEIGHT OF THE PRIVACY
 WALL INDICATED ON SHEETS A-1 & A-1B IS
 6'. PLEASE CORRECT.
  
 4) THE PRESSURES LISTED IN THE WINDOW
 PRESSURE SCHEDULE ON SHEETS A-4A & A-4B
 FOR (J,S,&T) DO NOT CORRESPOND WITH
 THOSE LISTED ON THE ELEVATION DRAWINGS
 ON THE SAME SHEETS. PLEASE CORRECT.
  
 5) SECTION 104.2.1 OF THE CITY OF W.P.B.
 AMENDMENTS TO THE 97 SBC REQUIRES
 INFORMATION TO BE SPECIFIC AND STATES
 THAT THE TECHINCAL CODES SHALL NOT BE
 CITED. ON SHEETS A-3A & A-8A THE STAIR
 DETAILS STATE THAT STAIRS ARE TO BE
 CONSTRUCTED IN ACCORDANCE W/SEC. 1007 OF
 1997 SBC. PLEASE PROVIDE DETAILS OF
 HANDRAILS AND GUARDRAILS, INCLUDING
 SPACING OF INTERMEDIATE RAILS, ETC.
  
 6) PER SEC.1007.3 OF 1997 SBC THE SUM OF
 2 RISERS AND 1 TREAD IS TO BE NOT LESS
 THAN 24" NOR MORE THAN 25". THE
 DIMENSIONS GIVEN ON SHEETS A-3A & A-8A,
 DO NOT COMPLY. PLEASE CORRECT.
  
 7) THE ALLOWABLE WINDLOADS LISTED IN THE
 PRODUCT APPROVAL FOR A 16'X7' GARAGE
 DOOR IS EXCEEDED BY THOSE GIVEN ON SHEET
 A-4A & A-4B. PLEASE CLARIFY.
  
 THESE SAME ISSUES ARE RECURRING ON THESE
 MODELS. PLEASE MAKE THESE CORRECTIONS TO
 THE ORIGIONALS TO HELP EXPEDIATE THE
 PLAN REVIEW PROCESS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-06-20 Cont ID  
Sent By lsmith Date 2000-06-20 Time 15:01 Rev Time 0.50
Received By lsmith Date   Time   Sent To  
Notes
2001-01-08 00:00:00FAILED PER TM 6/19/00

Review Stop Z ZONING
Rev No 3 Status P Date 2001-04-23 Cont ID  
Sent By sgraham Date 2001-04-23 Time 15:15 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2000-02-10 Cont ID  
Sent By gjoyce Date 2000-02-10 Time 15:52 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***