Plan Review Details - Permit 99121367
Plan Review Stops For Permit 99121367
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2000-03-15 Cont ID  
Sent By fknapp Date 2000-03-15 Time 16:20 Rev Time 6.00
Received By fknapp Date 2000-03-15 Time 16:20 Sent To  
Notes
2001-01-08 00:00:00 
 *****************PROVISO****************
  
 SBC 104.2.2
  
 1)PROVIDE 2 CURRENT COPIES OF SBCCI OR
 METRO DADE PRODUCT APPROVALS FOR ALL
 NEW EXTERIOR DOORS.
  
 PLEASE SUBMIT PRIOR TO INSTALLATION.
  
 2)PROVIDE MISSILE IMPACT PROTECTION
 INFORMATION FOR ALL NEW GLAZING UNDER
 SEPERATE PERMIT.
  
 DUE TO CHANGE IN SCOPE OF WORK PLANS
 HAVE BEEN REVISED AND VALUE RAISED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2000-01-20 Cont ID  
Sent By jcaloger Date 2000-01-20 Time 11:42 Rev Time 1.00
Received By jcaloger Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2000-05-17 Cont ID  
Sent By dpalmer Date 2000-05-17 Time 14:09 Rev Time 0.00
Received By dpalmer Date 2000-05-17 Time 14:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-04-10 Cont ID  
Sent By dpalmer Date 2000-04-10 Time 09:21 Rev Time 0.00
Received By dpalmer Date 2000-04-10 Time 09:20 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-01-05 Cont ID  
Sent By dpalmer Date 2000-01-05 Time 09:28 Rev Time 0.00
Received By dpalmer Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2000-03-14 Cont ID  
Sent By rturnque Date 2000-03-14 Time 09:21 Rev Time 0.20
Received By rturnque Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2000-01-12 Cont ID  
Sent By ndenmark Date 2000-01-12 Time 15:28 Rev Time 0.25
Received By ndenmark Date 2000-01-12 Time 15:28 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2000-01-21 Cont ID  
Sent By jcaloger Date 2000-01-21 Time 09:41 Rev Time 0.30
Received By jcaloger Date 2000-01-21 Time 09:41 Sent To  
Notes
2001-01-08 00:00:00APPROVED BY T.LARGE 1/21/00.
 PLBG.PLANS TO BE SUBMITTED AT LATER DATE

Review Stop P PLUMBING
Rev No 2 Status N Date 2000-01-21 Cont ID  
Sent By tlarge Date 2000-01-11 Time 15:26 Rev Time 0.50
Received By jcaloger Date   Time   Sent To  
Notes
2001-01-08 00:00:00KIT.SINKS NOT PERMITTED ON 2"VERTICAL
 COMBINATION WASTE AND VENT SYSTEM PER
 SPC SEC.911.4.
  
 SIZE ALL SECS.OF DWV SYSTEM PER COUNTY-
 WIDE AMENDMENTS TO SPC SEC.104.2.1.
  
 WATER CLOSETS NOT PERMITTED ON VERTICAL
 WASTE AND VENT SYSTEM PER 911.4.
  
 VENT STACK SHALL CONNECT TO HORIZ.WASTE
 PIPE PER SPC 906.2.1.BASE OF STACK SHALL
 BE WASHED.

Review Stop P PLUMBING
Rev No 1 Status N Date 2000-01-21 Cont ID  
Sent By tlarge Date 2000-01-04 Time 12:53 Rev Time 0.33
Received By jcaloger Date 2000-01-04 Time 12:53 Sent To  
Notes
2001-01-08 00:00:00CLARIFY EXTENT OF PLUMBING WORK BEING
 DONE.IF SANITARY LINES ARE BEING
 REROUTED,SUBMIT A SANITARY RISER THAT
 COMPLIES W/SPC AND REFLECTS SCOPE OF
 WORK PER COUNTYWIDE AMENDMENTS TO SPC
 SEC.104.2.1.

Review Stop Z ZONING
Rev No 1 Status N Date 2000-01-20 Cont ID  
Sent By jcaloger Date 2000-01-20 Time 11:42 Rev Time 0.00
Received By jcaloger Date   Time   Sent To  
Notes
***NONE***