Plan Review Details - Permit 99121347
Plan Review Stops For Permit 99121347
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2000-05-02 Cont ID  
Sent By dpalmer Date 2000-05-02 Time 08:17 Rev Time 0.00
Received By dpalmer Date 2000-05-02 Time 08:17 Sent To  
Notes
2001-01-08 00:00:00PROVISO
  
 NEED TO PROVIDE AIC RATINGS OF MAINS
 FOR ALL PLANS WHEN NEW SERVICES ARE
 BEING INSTALLED.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW BEFORE ANY ROUGH ELECTRICAL
 INSPECTION IS CALLED IN.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2000-04-17 Cont ID  
Sent By dpalmer Date 2000-04-17 Time 17:08 Rev Time 0.00
Received By dpalmer Date 2000-04-17 Time 17:08 Sent To  
Notes
2001-01-08 00:00:00**************UNSAT *****************
  
 THIS IS MOSTLY INFORMATION PREVIOUSLY
 ASKED FOR!!!!
  
  
  
 1)NOTE: PLEASE SUBMIT THE AIC RATING OG
 THE EQUIPMENT MAINS. MAINS MUST BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
 PER 110-9/215-5 THIS MUST BE SUBMITTED
 ON ALL PLANS!!1
  
 2)NOTE:PLEASE SHOW ALL A/C COND. UNITS
 AND DISC 440-11 AND REQ`D WP GFI
  
 3)NOTE: MISSING OUTLETS REQ`D PER 210-52
 2` 6` 12 RULE.
  
 4)NOTE: ALSO, NEED TO SHOW ALL OUTLETS
 SERVING ANY COUNTER SPACES IN KITCHEN
 AS BEING GFI/GFI PROTECTED.210-8-A-6
 INCLUDING KITCHEN ISLAND/NOOK
  
 CHECK ORIGINAL NOTES!!YOU NEED TO SUB-
 MIT NEW ELECTRICAL SHEETS!!! AS REQ`D BY
 \\215-5 ONLY ELECTRICAL. PLEASE TAKE ALL
 BUILDING NOTES OFF E-SHEETS, AND THE
 STRUCTURE DETAILS.
 THESE ARE NOTES THAT WERE ASKED TO BE
 TAKEN CARE OF ON THE FIRST REVIEW.
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
 659-8096 EXT 8372
  
 ALSO OUTLETS IN UTILITY ROOM NEED TO BE
 GFI/GFI PROTECTED. 210-8-A-2 PLEASE SHOW

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-01-08 Cont ID  
Sent By dpalmer Date 2000-01-08 Time 17:34 Rev Time 0.00
Received By dpalmer Date 2000-01-08 Time 17:34 Sent To  
Notes
2001-01-08 00:00:00*************** UNSAT ******************
  
 THE FOLLOWING IS A LIST FOR WHICH NEEDS
 TO BE COMPLETELY TAKEN CARE OF!
  
 1)NOTE:NEED TO SHOW BLDG.STEEL AS PART
 OF THE GORUNDING ELECTRODE SYSTEM. AS
 REQ`D BY ART;250-81/215-5
  
 2)NOTE: A 18 POLE PANEL IS SHOWN! THIS
 PANEL DOES NOT HAVE ENOUGH SPACES!!!
 PLEASE COUNT BRKRS AND INCLUDE TWO
 SPARE SPACES AS REQ`D BY NEC.
  
 3)NOTE:PLEASE CHECK A/C HEAT THAT IS
 GOING TO BE INSTALLED?? MOST ARE 7500KW
 IN WHICH CASE,,PLEASE CHANG LOAD CALC.
  
 4)NOTE:#8 IS NOT REQ`D FOR DRYER AND HOT
 WATER HEATER BUT MAY BE INSTALLED.
  
 5)NOTE:PLANS SHOW 3310 SQ.FT OF LIVING
 SPACE BEING BUILT!! THE LOAD CALCULATION
 -S DO NOT MATCH. PLEASE REFIGURE TO
 NEC.
  
 6)NOTE:PANEL SCHEDULE NEED TO SHOW
 DEDICATED BATH(S) CIRCUT AND NEEDS TO BE
 20AMP #12 AWG. AS REQ`D BY ART;210-52D/
 215-5
  
 7)NOTE:PLANS NEED TO SHOW A/C COND.UNIT
 WITH MEANS OF DISC. PER 440-1 AND WP
 GFI REC. REQ`D BY 210-63
  
 8)NOTE:PLANS ARE MISSING REC. AS REQ`D
 BY ART;210-52E OF THE NEC.
  
 9)NOTE:AS REQ`D BY ART;210-52-C-1
 NEED TO SPACE OUTLETS TO MEET CODE ALONG
 KITCHEN COUNTERSPACE.
  
 10)NOTE: PLANS SHOW NOOK??? IN KITCHEN??
 IS THIS AN ISLAND? IF SO THEN OUTLETS
 MUST CONFORM TO ART;210-52-C-3 OF THE
 NEC.
 11)NOTE:ALSO AS REQ`D BY ART;210-8-A-6
 OF THE NEC. ALL OUTLETS SERVING KITCHEN
 COUNTERSPACE ARE TO BE GFI/GFI PROTECTED
 PLEASE SHOW!!!
  
 12)NOTE:PLANS SHOW NO MEANS OF EGRESS
 LIGHTING WHICH IS REQ`D BY ART;210-70
 AT THE FRONT DOOR.???
  
 13)NOTE:AS REQ`D BY ART;210-8-A-2 RECEPT
 -S IN UTILITY ROOM MUST BE GFI.
  
 14)NOTE:BEDROOM #3 SHOWS NO DOOR???
 AS REQ`D BY 1993.1996 NFPA-72 2-2.1.1.1
 SMOKE DETECTORS ARE REQ`D INSIDE AND
 OUTSIDE ALL SLEEPING ROOMS OF NEW
 DWELLINGS.ALL,,,
  
 PLEASE HAVE ALL THE ABOVE INFORMATION
 SUBMITTED FOR REVIEW AND APPROVAL.
 ALSO PLEASE HAVE ELECTRICAL DRAWN ON
 THERE OWN SHEET FOR BETTER CLARITY OF
 WORK TO BE DONE. 215-5
 IF THERE ARE ANY QUESTIONS ABOUT COMMENT
 -S. PLEASE CALL 659-8096 EXT 8372 TO SET
 UP A MEETING.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-01-18 Cont ID  
Sent By jleech Date 2000-01-18 Time 15:37 Rev Time 0.35
Received By jleech Date 2000-01-18 Time 15:37 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2001-03-14 Cont ID  
Sent By jleech Date 2001-03-14 Time 18:21 Rev Time 0.25
Received By jleech Date 2001-03-14 Time 18:21 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-04-17 Cont ID  
Sent By tlarge Date 2000-04-17 Time 12:31 Rev Time 0.33
Received By tlarge Date 2000-04-17 Time 12:31 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date   Cont ID  
Sent By tlarge Date 2000-01-04 Time 16:47 Rev Time 0.33
Received By tlarge Date 2000-01-04 Time 16:47 Sent To  
Notes
2001-01-08 00:00:00LOCATION OF PLUMBING FIXTURES ON
 SANITARY RISER SHALL MATCH THE FLOOR
 PLAN PER COUNTYWIDE AMENDMENTS TO SPC
 SEC.104.2.1.
  
 SANITARY RISER SHALL COMPLY W/SPC.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2000-04-17 Cont ID  
Sent By fknapp Date 2000-04-17 Time 07:30 Rev Time 3.00
Received By fknapp Date 2000-04-17 Time 07:30 Sent To  
Notes
2001-01-08 00:00:00 
  
 *****************PROVISO****************
  
 SBC 104.2.2
  
 1)PROVIDE 2 CURRENT COPIES OF SBCCI OR
 METRO DADE PRODUCT APPROVALS FOR FRONT
 ENTRY DOOR ASSEMBLY WITH SIDELITES.
  
 2)PROVIDE INSTALLATION SCHEDULE AND KEY
 PLAN FOR STORM PANELS WITH SPECIFIC
 ANCHORS TO BE USED.
  
 3)PROVIDE ROOF FRAMING PLAN APPROVED BY
 DESIGNER OF RECORD.
  
 4)PROVIDE SAFETY GLASS AS REQUIRED
 1997 SBC 2405.2.
  
 PLEASE SUBMIT PRIOR TO INSTALLATION.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-02-11 Cont ID  
Sent By fknapp Date 2000-02-11 Time 10:16 Rev Time 5.00
Received By fknapp Date 2000-02-10 Time 13:46 Sent To  
Notes
2001-01-08 00:00:00 
 ****************DENIED******************
 SBC 104.2.2
 1)PROVIDE 2 CURRENT COPIES OF SURVEY.
  
 2)PROVIDE OWNER SIGNATURE ON ENERGY
 CALCULATIONS.
  
 3)PROVIDE MISSILE IMPACT PROTECTION
 INFORMATION.
  
 4)PROVIDE 2 CURRENT COPIES OF PRODUCT
 APPROVALS FOR:
 ROOF COVERING
 EXTERIOR DOORS
  
 5)PROVIDE WALL SECTIONS THAT MATCH.
  
 6)PROVIDE ACCESS TO BEDROOM 3.
  
 7)PROVIDE ROOF FRAMING PLAN WITH UPLIFT
 CALCULATIONS AND ANCHOR SCHEDULE.
  
 8)PROVIDE WINDOW AND DOOR BUCK DETAILS
 WITH CONNECTIONS FOR WINDLOAD SBC 1606
  
 9)PROVIDE WINDOWS THAT COMPLY WITH
 EGRESS REQUIREMENTS.
  
 10)PROVIDE DESIGN PRESSURE CALCULATIONS
 FOR ALL EXTERIOR DOOR AND WINDOW
 OPENINGS.
  
 11)PROVIDE SEAL AND SIGNATURE OF
 ENGINEER ON PLANS THAT SUBMITTED DESIGN
 CERTIFICATION FOR BUILDING CODE
 COMPLIANCE.
  
 12)PROVIDE QUALIFIED SOIL TECHNICIAN
 TO MONITOR SITE PREPERATION AND
 EARTHWORK PER SOIL REPORT.
  
 13)PROVIDE ELEVATIONS THAT MATCH LAYOUT
 THAT IS SHOWN ON FLOOR PLAN.
  
 ****************NOTE********************
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED,IMPACT FEES MUST BE PAID TO PALM
 BEACH CO.,THE PLANS STAMPED BY THEM AND
 THE RECIEPT ATTACHED TO THE PERMIT
 APPLICATION.

Review Stop Z ZONING
Rev No 1 Status P Date 1999-12-29 Cont ID  
Sent By gjoyce Date 1999-12-29 Time 08:16 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***