Plan Review Details - Permit 99121189
| Plan Review Stops For Permit 99121189 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2000-02-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-02-05 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-02-05 |
Time |
10:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2000-07-03 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-07-03 |
Time |
12:17 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-07-03 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED: | | | NO MECHANICAL PLANS SUBMITTED FOR REVIEW |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2000-01-20 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-01-20 |
Time |
14:24 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-01-20 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NO A/C PLANS SUBMITTED OWNER/BUILDER | | | WILL SUBMIT ON A LATER DATE |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-01-08 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-01-08 |
Time |
15:17 |
Rev Time |
0.33 |
| Received By |
tlarge |
Date |
2000-01-08 |
Time |
15:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2000-04-21 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-04-21 |
Time |
12:37 |
Rev Time |
2.00 |
| Received By |
fknapp |
Date |
2000-04-20 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ****************DENIED****************** | | | | | | SBC 104.2.2 | | | | | | 1)PROVIDE OWNER SIGNATURE ON BOTH ENERGY | | | CALCULATIONS. | | | | | | 2)PROVIDE ENGINEER APPROVAL OF PILINGS | | | BEFORE ANY CONCRETE IS POURED. | | | | | | 3)PROVIDE FLOOD ZONE ELEVATION | | | CERTIFICATE. | | | | | | 4)PROVIDE AC PLAN WITH MECHANICAL PERMIT | | | APPLICATION. | | | | | | 5)PROVIDE 2 CURRENT COPIES OF SBCCI OR | | | METRO DADE PRODUCT APPROVALS WITH | | | APPROVED DRAWINGS FOR: | | | EXTERIOR DOORS AND WINDOWS | | | ROOF COVERING | | | STORM PANELS WITH INSTALLATION | | | SCHEDULE AND KEY PLAN WITH SPECIFIC | | | ANCHORS TO BE USED. | | | | | | 6)PROVIDE SPECIFICATIONS FOR UL LISTED | | | FIREPLACE. | | | | | | 7)PROVIDE DETAILS OF SPIRAL STAIRS TO | | | COMPLY WITH SBC 1007.8.2 | | | | | | 8)PROVIDE HANDRAILS AND GUARDRAILS TO | | | COMPLY WITH SBC 1015 | | | | | | 9)PROVIDE SAFETY GLASS PER SBC 2405.2.1 | | | | | | 10)PROVIDE DETAILS OF ALL STRUCTUAL | | | COMPONETS. MUST COMPLY WITH TBL 600, | | | TYPE VI 1 HR PROTECTED. | | | | | | 11)PROVIDE APPROVED ASSEMBLIES TO MEET | | | FIRE RESISTANCE REQUIREMENTS SBC 701.5 | | | | | | 11)SHOW FINISH FLOOR ELEVATIONS RELATIVE | | | TO NGVD. | | | | | | ******************NOTE****************** | | | ALL CHANGES ON PLANS MUST BE NOTED BY | | | TRIANGLES OR CLOUDS. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2000-02-09 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-02-09 |
Time |
14:52 |
Rev Time |
5.00 |
| Received By |
fknapp |
Date |
2000-02-09 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | | | | ****************DENIED****************** | | | | | | SBC 104.2.2 | | | | | | 1)PROVIDE OWNER SIGNATURE ON ENERGY | | | CALCULATIONS. | | | | | | 2)PROVIDE ENGINEER APPROVAL OF PILINGS | | | BEFORE ANY CONCRETE IS POURED. | | | | | | 3)PROVIDE FLOOD ZONE ELEVATION | | | CERTIFICATE. | | | | | | 4)PROVIDE AC PLAN WITH MECHANICAL PERMIT | | | APPLICATION. | | | | | | 5)PROVIDE 2 CURRENT COPIES OF PRODUCT | | | APPROVALS FOR: | | | EXTERIOR DOORS AND WINDOWS | | | STORM PANELS | | | ROOF COVERING | | | FIREPLACE UL LISTED | | | | | | 6)BUILDING SHOWN IS TYPE VI CONSTRUCTION | | | AND DOES NOT COMPLY WITH SBC TABLE 500 | | | REVISE DESIGN TO COMPLY. | | | | | | 7)PROVIDE CONSTRUCTION DETAILS OF FIRE | | | RATED ASSEMBLY FOR ELEVATOR HOISTWAY | | | SBC 705.1.2 | | | | | | 8)PROVIDE DETAILS OF SPIRAL STAIRS TO | | | COMPLY WITH SBC 1007.8.2 | | | | | | 9)PROVIDE ATTIC ACCESS PER SBC 2309.6 | | | | | | 10)PROVIDE GUARDRAILS TO COMPLY WITH | | | SBC 1015 | | | | | | 11)PROVIDE SAFETY GLASS PER SBC 2405.2.1 | | | | | | 12)PROVIDE CONSTRUCTION DETAILS OF FIRE | | | RATED ASSEMBLY FOR LAUNDRY CHUTE | | | SBC 705.1.2 | | | | | | **************NOTE********************** | | | BEFORE A PERMIT TO CONSTRUCT CAN BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH CO.,THE PERMIT PLANS STAMPED BY | | | THEM AND THE RECIEPT ATTACHED TO THE | | | PERMIT APPLICATION. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2000-07-11 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-07-11 |
Time |
14:41 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NO SURVEY OR SITE PLAN |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
1999-12-30 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
1999-12-30 |
Time |
11:29 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
1999-12-29 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
1999-12-29 |
Time |
08:06 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NEEDS SITE PLAN |
|
|
|