| Plan Review Stops For Permit 99121094 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2000-03-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-03-01 |
Time |
06:45 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-03-01 |
Time |
06:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2000-02-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-02-28 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-02-28 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SAME NOTES AS BEOFORE. ONLY TWO NOTES | | | WERE ADDRESSED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-01-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-01-08 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-01-08 |
Time |
12:55 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ************UNSAT******************* | | | | | | 1)NOTE: RISER DIAGRAM SHOWS MAIN DISC. | | | PLANS DO NOT SHOW MAIN DISCONNECT NEXT | | | TO METER.?? PLEASE CORRECT.215-5 | | | | | | 2)NOTE:PANEL SCHEDULE SHOWS 48 CIRCUT | | | PANELBOARD. AS PER 384-15 NO MORE THAN | | | 42 CIRCUT PANEL ARE ALLOWED. | | | | | | 3)NOTE: AS PER 210-52D/215-5 NEED TO | | | SHOW DEDICATED BATH(S) CIRCUT REQ`D.NEED | | | TO BE 20AMP #12 AWG. | | | | | | 4)NOTE;AS REQ`D BY 210-8-A-6 ALL OUTLETS | | | SERVING KITCHEN COUNTERSPACE ARE TO BE | | | GFI/GFI PROTECTED.PLEASE SHOW. | | | | | | 5)NOTE:NEED TO SUBMIT AIC RATING OF | | | EQUIPMENT MAINS/BRKRS. AS REQ`D BY THE | | | FOLLOWING ARTS:110-9/230-65/215-5 | | | AIC RATING IS FIGURED FROM FAULT CURRENT | | | CALCULATIONS. | | | | | | 6)NOTE: AS REQ`D BY 1993/1996 NFPA-72 | | | CHAPTER 2-2.1.1.1 SMOKE DETECTORS SHALL | | | BE INSTALLED INSIDE AND OUTSIDE ALL | | | SLEEPING ROOMS IN NEW DWELLINGS. | | | | | | PLEASE HAVE ALL THE ABOVE INFORAMTION | | | SUBMITTED FOR REVIEW AND APPROVAL | | | BEFORE FIRST ROUGH ELECTRIACL INSPECTION | | | IS CALLED IN. IF THERE ARE ANY QUESTIONS | | | CALL 659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2000-07-21 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-07-21 |
Time |
07:20 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-07-21 |
Time |
07:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2000-05-09 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-05-09 |
Time |
13:12 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-05-09 |
Time |
13:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
1999-12-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
1999-12-27 |
Time |
15:44 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
1999-12-27 |
Time |
15:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2000-03-01 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-03-01 |
Time |
06:56 |
Rev Time |
0.33 |
| Received By |
tlarge |
Date |
2000-03-01 |
Time |
06:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
1999-12-27 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-12-27 |
Time |
07:43 |
Rev Time |
0.50 |
| Received By |
tlarge |
Date |
1999-12-27 |
Time |
07:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2000-03-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2000-03-01 |
Time |
08:48 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2000-03-01 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | APPROVED WITH PROVISO: | | | 1-FLOOD ZONE A8. PROVIDE ELEVATION | | | CERTIFICATE. | | | 2-UPDATE/REVISE ALL DRAWINGS AS REQUIRED | | | SEE PLANS FOR COMMENTS. | | | 3-ENGINEER TO SIGN, SEAL AND DATE SOIL | | | TEST REPORT. | | | 4-STORM PANELS: | | | -REVISE/UPDATE INSTALLATION SCHEDULE | | | AND KEY PLAN TO MATCH FLOOR PLANS. | | | NOTE: USE CITY SAMPLE INSTALLATION | | | SCHEDULE, ATTACHED, AND FILL IN ALL | | | THE INFORMATION. | | | 5-PROVIDE PRODUCT APPROVAL FOR ENTRY | | | OUTSWING DOOR AND GARAGE DOOR. | | | NOTE: CLEARLY SPECIFY THE FASTENERS | | | TO BE USED ACCORDING TO THE PRODUCT | | | APPROVAL AND DOOR FRAME DETAIL THAT | | | WAS SPECIFIED IN DRAWING A6. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2000-01-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2000-01-29 |
Time |
16:14 |
Rev Time |
2.50 |
| Received By |
jgomez |
Date |
2000-01-29 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | CHECKLIST: | | | 1-PAY IMPACT FEES. | | | 2-UPDATE/REVISE ALL DRAWINGS. SEE | | | COMMENTS ON PLANS. | | | 3-FLOOD ZONE A8. WILL NEED TO PROVIDE | | | AN ELEVATION CERTIFICATE. | | | 4-ENGINEER TO SIGN, SEAL AND DATE THE | | | SOIL TESTS REPORT. | | | 5-REVISE SIZE OF BEDROOM #2 WINDOW TO | | | MEET THE EGRESS REQUIREMENTS. SEC | | | 1005.4.4 SBC 1997. | | | 6-STORM PANELS: | | | -PRODUCT APPROVAL DOESN'T MATCH DWGS. | | | -REVISE/UPDATE INSTALLATION SCHEDULE | | | AND KEY PLAN TO MATCH FLOOR PLANS. | | | COMPLETELY FILL THE INSTALLATION | | | SCHEDULE AS PER CITY SAMPLE. ATTACHED. | | | -NOTE: SPECIFY ANCHOR SPACING ACCORDING | | | TO THE BUILDING CONSTRUCTION. THIS IS | | | MASONRY CONSTRUCTION, NOT CONCRETE. | | | HIGHLIGHT ALL MOUNTING CONDITIONS AND | | | ANCHORS TO BE USED. | | | 7-PROVIDE COMPLETE BUCK DETAILS FOR | | | EXTERIOR DOORS, WINDOWS AND GARAGE | | | DOOR. | | | 8-PROVIDE PRODUCT APPROVAL FOR ENTRY | | | DOOR WITH SIDELITES ASSEMBLY AND | | | GARAGE DOOR. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
1999-12-23 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
1999-12-23 |
Time |
08:49 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|