Plan Review Details - Permit 99120679
Plan Review Stops For Permit 99120679
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-08-02 Cont ID  
Sent By dpalmer Date 2000-08-02 Time 16:07 Rev Time 0.00
Received By dpalmer Date 2000-08-02 Time 16:07 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-01-08 Cont ID  
Sent By dpalmer Date 2000-01-08 Time 12:13 Rev Time 0.00
Received By dpalmer Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-12-27 Cont ID  
Sent By jleech Date 1999-12-27 Time 14:59 Rev Time 0.50
Received By jleech Date 1999-12-27 Time 14:59 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 1999-12-23 Cont ID  
Sent By tlarge Date 1999-12-23 Time 06:31 Rev Time 0.33
Received By tlarge Date 1999-12-23 Time 06:31 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2000-03-09 Cont ID  
Sent By jgomez Date 2000-03-09 Time 15:18 Rev Time 1.00
Received By jgomez Date 2000-03-09 Time 15:18 Sent To  
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-REVISE THE DESIGN CERTIFICATION FOR
 BUILDING CODE COMPLIANCE FORM. THE
 MEAN ROOF HEIGHT IS TAKEN FROM GRADE,
 NOT FROM FINISH FLOOR, TO THE AVERAGE
 POINT OF THE HIGHEST ROOF. THEREFORE,
 THE MEAN ROOF HEIGHT FOR THIS BUILDING
 IS PLUS OR MINUS 19'-4".
 NOTE: REVISE DRAWING #1 AS WELL.
 2-PROVIDE COPIES OF THE APPROVED DRAWING
 FOR ENTRY DOORS PRODUCT APPROVAL.
 3-PROVIDE SOIL TEST REPORT.
 NOTE: SEE SECTION 1804.2.7.2 OF CITY
 AMENDMENTS FOR MINIMUN REQUIREMENTS.
 -PROVIDE TWO COPIES OF SOIL TEST REPORT
 SIGNED, SEALED AND DATED. (EMBOSSED
 SEAL).
 4-STORM PANELS:
 -UPDATE INSTALLATION SCHEDULE AND KEY
 PLAN TO MATCH ARCHITECT'S FLOOR PLAN
 AND EXTERIOR ELEVATIONS.
 -REVISE PANELS #2 AND #16. PANELS THAT
 ARE LONGER 9'-4" SHALL BE BOLTED. SEE
 NOTE #7 ON GENERAL NOTES OF PRODUCT
 APPROVAL, SHEET 1 OF 8.
 -SPECIFY ANCHOR SPACING FOR PANELS THAT
 ARE LONGER THAN 8'-0".

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2000-03-06 Cont ID  
Sent By jgomez Date 2000-03-06 Time 17:12 Rev Time 2.50
Received By jgomez Date 2000-03-06 Time 17:12 Sent To  
Notes
2001-01-08 00:00:001-PAY IMPACT FEES TO THE COUNTY.
 2-OWES $470.05 TO THE CITY OF WEST PALM
 BEACH FOR LOW VALUATION AND RADON FEES
 3-OWNER/AGENT TO SIGN AND DATE THE
 ENERGY CALCULATIONS.
 4-REVISE THE DESIGN CERTIFICATION FOR
 BUILDING CODE COMPLIANCE FORM. THE
 MEAN ROOF HEIGHT IS TAKEN FROM GRADE,
 NOT FROM FINISH FLOOR, TO AN AVERAGE
 POINT AT THE HIGHEST ROOF. THEREFORE,
 THE MEAN ROOF HEIGHT FOR THIS HOUSE
 IS PLUS OR MINUS 9'-4".
 NOTE: REVISE DRAWING #1 AS WELL.
 5-ENTRY DOORS PRODUCT APPROVAL: PROVIDE
 COPIES OF THE APPROVED DRAWINGS.
 6-PROVIDE SOIL TEST REPORT AS PER CITY
 AMENDMENTS SECTION 1804.2.7.2. SEE
 ATTACHED. PROVIDE TWO COPIES SIGNED,
 SEALED AND DATED.
 7-STORM PANELS:
 -UPDATE INSTALLATION SCHEDULE AND KEY
 PLAN TO MATCH ARCHITECT'S FLOOR PLANS
 AND EXTERIOR ELEVATIONS.
 -REVISE PANELS #2 AND #16. PANELS
 LONGER THAN 9'-4" SHALL BE BOLTED. SEE
 NOTE #7 ON GENERAL NOTES OF PRODUCT
 APPROVAL, SHEET 1 OF 8.
 -SPECIFY ANCHOR SPACING FOR PANELS
 LONGER THAN 8'-0".

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-01-27 Cont ID  
Sent By jgomez Date 2000-01-27 Time 15:50 Rev Time 2.50
Received By jgomez Date 2000-01-27 Time 15:50 Sent To  
Notes
2001-01-08 00:00:00CHECKLIST:
 1-PAY IMPACT FEES TO PALM BEACH COUNTY.
 BRING STAMPED DRAWINGS AND RECEIPT.
 2-EGRESS OPENING FROM "ATRIUM" AREA TO
 HAVE 5 SQUARE FEET OF CLEAR OPENING
 MINIMUM. SEC 1005.4.4 SBC 1997.
 -TOP OF PRIVACY WALL AT "ATRIUM" TO BE
 UP TO THE BOTTOM OF LINTEL OF SLIDING
 GLASS DOOR. REVISE HEIGHT AS REQUIRED.
 3-PROVIDE COMPLETE DETAILS FOR
 INSTALLATION OF AHU HUNG FROM TRUSSES.
 SPECIFY ALL CONNECTORS.
 4-ENERGY CALCULATIONS TAKE CREDIT FOR
 CEILING FANS. SPECIFY SIZES OF FANS AS
 PER TABLE 6-6 OF FLORIDA ENERGY CODE
 1997 EDITION.
 5-REVISE WIND LOAD CERTIFICATION FORM
 AS REQUIRED.
 6-ENERGY CALCULATIONS TO BE SITE
 SPECIFIC. FILL IN ALL INFORMATION ON
 TOP PORTION OF FORM 600A-97 AND
 OWNER/AGENT TO SIGN AND DATE FORM AS
 WELL.
 -NOTE: THE CLIMATE ZONE IS #8 NOT
 SOUTH. SOUTH IS THE REGION. REVISE AS
 REQUIRED.
 7-PROVIDE PRODUCT APPROVAL FOR ROOF TILE
 AND CLEARLY SPECIFY FASTENING METHOD.
 -SEE COMMENTS ON FRONT PAGE OF ALL
 PRODUCT APPROVALS SUBMITTED AND
 HIGHLIGHT THE COMPONENTS AS REQUIRED.
 8-SEE COMMENTS ON ARCHITECTURAL PLANS
 AND REVISE/UPDATE DRAWINGS AS REQUIRED
 9-PROVIDE SOIL TEST REPORT.
 10-OWES $470.05 TO THE CITY OF WEST PALM
 BEACH FOR LOW VALUATION AND RADON FEES
 11-STORM PANELS:
 -PROVIDE A COMPLETE INSTALLATION
 SCHEDULE (AS PER CITY SAMPLE) AND KEY
 PLAN.
 -HIGHLIGHT SPECIFIC MOUNTING CONDITIONS
 USED IN THIS PROJECT.
 -HIGHLIGHT SPECIFIC ANCHORS TO BE USED
 ACCORDING TO THE DESIGN PRESSURES,
 PANEL SPAN, BUILDING CONSTRUCTION ETC.
 NOTE: THIS BUILDING IS MASONRY
 CONSTRUCTION. USE ANCHORS AS REQUIRED.

Review Stop Z ZONING
Rev No 1 Status P Date 1999-12-22 Cont ID  
Sent By gjoyce Date 1999-12-22 Time 09:19 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***