Plan Review Details - Permit 99120678
| Plan Review Stops For Permit 99120678 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2000-01-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-01-08 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-01-08 |
Time |
12:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-01-04 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-01-04 |
Time |
15:28 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2000-01-04 |
Time |
15:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2000-05-18 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-05-18 |
Time |
06:33 |
Rev Time |
0.25 |
| Received By |
tlarge |
Date |
2000-05-18 |
Time |
06:33 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | REVISED SANITARY RISER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
1999-12-23 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-12-23 |
Time |
18:03 |
Rev Time |
0.33 |
| Received By |
tlarge |
Date |
1999-12-23 |
Time |
18:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2000-03-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2000-03-08 |
Time |
16:33 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2000-03-08 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | APPROVED WITH PROVISO: | | | 1-PROVIDE SURVEY SHOWING BUILDING LAYOUT | | | ALSO, SURVEY SHALL BE DATED THE DAY | | | THAT IT WAS SIGNED AND SEALED BY THE | | | SURVEYOR. | | | 2-PROVIDE SOIL TEST REPORT. CHECK CITY | | | AMENDMENTS SECTION 1804.2.7.2 FOR | | | MINIMUM REQUIREMENTS. | | | 3-STORM PANELS: | | | -CLEARLY FILL IN ANCHOR SPACING IN THE | | | INSTALLATION SCHEDULE TABLE. | | | -SPECIFY ANCHOR SPACING FOR PANELS | | | LONGER THAN 8'-0". SEE PRODUCT | | | APPROVAL DRAWINGS. | | | 4-PROVIDE PRODUCT APPROVAL FROM DADE | | | COUNTY OR SBCCI FOR THE GARAGE DOOR. | | | NOT FROM BROWARD COUNTY. | | | 5-PROVIDE PRODUCT APPROVAL FOR ENTRY | | | DOOR WITH SIDELITES ASSEMBLY. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2000-03-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2000-03-07 |
Time |
19:00 |
Rev Time |
2.50 |
| Received By |
jgomez |
Date |
2000-03-07 |
Time |
19:00 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1-PAY IMPACT FEES TO THE COUNTY. | | | 2-OWES $643.87 TO THE CITY OF WEST PALM | | | BEACH FOR LOW VALUATION AND RADON FEES | | | 3-PROVIDE SURVEY SHOWING BUILDING LAYOUT | | | ALSO, SURVEY SHALL BE DATED THE DAY IT | | | IS SIGNED AND SEALED BY THE SURVEYOR. | | | 4-PROVIDE SOIL TEST REPORT AS PER CITY | | | AMENDMENTS SECTION 1804.2.7.2. SEE | | | ATTACHED. | | | 5-STORM PANELS: | | | -CLEARLY FILL IN ANCHOR SPACING IN | | | THE INSTALLATION SCHEDULE TABLE. | | | -SPECIFY ANCHOR SPACING FOR PANELS | | | LONGER THAN 8'-0". | | | 6-PROVIDE PRODUCT APPROVAL FROM DADE | | | COUNTY OR SBCCI FOR THE GARAGE DOOR. | | | PRODUCT APPROVAL FROM BROWARD COUNTY | | | IS NOT ACCEPTABLE BY THIS OFFICE. | | | 7-PROVIDE PRODUCT APPROVAL FOR ENTRY | | | DOOR WITH SIDELITES ASSEMBLY. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2000-01-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2000-01-26 |
Time |
11:46 |
Rev Time |
3.00 |
| Received By |
jgomez |
Date |
2000-01-26 |
Time |
11:45 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | CHECKLIST: | | | 1-PAY IMPACT FEES TO PALM BEACH COUNTY. | | | 2-REVISE ENERGY CALCULATIONS.SEE | | | COMMENTS ON FRONT PAGE OF FORM 600A-97 | | | 3-PROVIDE PRODUCT APPROVAL FOR ROOF TILE | | | HIGHLIGHT SPECIFIC FASTENING METHOD. | | | 4-SEE COMMENTS ON PRODUCT APPROVALS FOR | | | DOORS, WINDOWS AND MULLIONS AND RE- | | | SUBMIT AS REQUIRED. | | | 5-SEE COMMENTS ON ARCHITECTURAL PLANS | | | AND UPDATE/CLARIFY DRAWINGS AND NOTES | | | AS REQUIRED. | | | 6-SURVEY SUBMITTED IS INCORRECT. PROVIDE | | | CORRECT SURVEY WITH HOUSE LAYOUT. | | | 7-PROVIDE SOIL TEST REPORT. | | | 8-OWES $643.87 TO THE CITY OF WEST PALM | | | BEACH FOR LOW VALUATION AND RADON FEES | | | 9-STORM PANELS: | | | - PROVIDE A COMPLETE INSTALLATION | | | SCHEDULE (AS PER CITY SAMPLE ATTACHED) | | | AND KEY PLAN. | | | -HIGHLIGHT SPECIFIC MOUNTING CONDITIONS | | | USED IN THIS PROJECT. | | | -HIGHLIGHT SPECIFIC ANCHOR TO BE USED | | | ACCORDING TO THE DESIGN PRESSURES, | | | PANEL SPAN, BUILDING CONSTRUCTION ETC. | | | NOTE: | | | THIS BUILDING IS MASONRY CONSTRUCTION. | | | USE ANCHORS AS REQUIRED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
1999-12-22 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
1999-12-22 |
Time |
09:13 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy