Plan Review Details - Permit 99120435
Plan Review Stops For Permit 99120435
Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-12-23 Cont ID  
Sent By dpalmer Date 1999-12-23 Time 11:33 Rev Time 0.00
Received By dpalmer Date   Time   Sent To  
Notes
2001-01-08 00:00:00NOTE ON PLANS FOR SMOKE DETECTORS AND
 CIRCUT FOR BATH AS PER 210-52D.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 1999-12-27 Cont ID  
Sent By jleech Date 1999-12-27 Time 15:15 Rev Time 0.25
Received By jleech Date 1999-12-27 Time 15:15 Sent To  
Notes
2001-01-08 00:00:00NO A/C SHOWN ON DRAWINGS.
 A/C CONTRACTOR TO SUBMIT DRAWING WITH
 PERMIT APPLICATION.

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-02-23 Cont ID  
Sent By tlarge Date 2000-02-23 Time 06:56 Rev Time 0.33
Received By tlarge Date 2000-02-23 Time 06:48 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2000-02-23 Cont ID  
Sent By tlarge Date 1999-12-23 Time 07:06 Rev Time 0.33
Received By tlarge Date 1999-12-23 Time 07:06 Sent To  
Notes
2001-01-08 00:00:00SUBMIT SANITARY ISOMETRIC FOR SCOPE OF
 PLBG.WORK TO BE DONE.
  
 LENGTH AND WIDTH OF SHOWER REQD.MIN.1024
 SQ.INCHES.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2000-03-10 Cont ID  
Sent By fknapp Date 2000-03-10 Time 15:21 Rev Time 2.00
Received By fknapp Date 2000-03-10 Time 15:20 Sent To  
Notes
2001-01-08 00:00:00 
  
 *****************PROVISO****************
  
 SBC 104.2.2
  
 1)PROVIDE 2 CURRENT COPIES OF SBCCI OR
 METRO-DADE PRODUCT APPROVALS FOR NEW
 EXTERIOR DOORS WITH SIDELITES.
  
 2)PROVIDE STRUCUAL ENGINEERING FOR
 PARALAM TYPE BEAM.
  
 PLEASE SUBMIT PRIOR TO INSTALLATION.
  
 3)PROVIDE MISSILE IMPACT PROTECTION
 INFORMATION UNDER SEPERATE PERMIT.
  
 4)PROVIDE MECHANICAL INFORMATION WITH
 MECHANICAL PERMIT APPLICATION.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2000-02-23 Cont ID  
Sent By fknapp Date 2000-02-23 Time 16:01 Rev Time 3.00
Received By fknapp Date 2000-02-23 Time 16:01 Sent To  
Notes
2001-01-08 00:00:00 
  
 *****************DENIED*****************
  
 SBC 104.2.2
  
 1)PROVIDE CONSTRUCTION DETAILS,COMPLETE
 WALL SECTIONS,FONDATION PLAN,DIMENSIONS
 AND MATERIALS TO BE USED AND SCOPE OF
 WORK TO BE DONE.
  
 2)PROVIDE 2 CURRENT COPIES OF METRODADE
 OR SBCCI PRODUCT APPROVALS FOR ALL NEW
 EXTERIOR DOORS AND WINDOWS.
  
 3)PROVIDE WINDOW AND DOOR BUCK
 CONNECTION DETAILS SBC 1606.
  
 4)PROVIDE MISSILE IMPACT PROTECTION
 INFORMATION UNDER SEPERATE PERMIT.
  
 5)PROVIDE MECHANICAL INFORMATION WITH
 MECHANICAL PERMIT APPLICATION.
  
 6)PROVIDE RECIEPT FROM PAID IMPACT FEES
 ATTACHED TO PERMIT APPLICATION.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-01-10 Cont ID  
Sent By jcaloger Date 2000-01-10 Time 09:49 Rev Time 0.25
Received By jcaloger Date   Time   Sent To  
Notes
2001-01-08 00:00:00PROVIDE CONSTRUCTION DETAILS.MISSING
 WALL SECTION , FOUNDATION PLAN, ROOF
 FRAMING PLAN.
  
 PROVIDE PRODUCT APPROVAL FOR THE WINDOW
 DOORS AND ROOFING.
  
 NEEDS COUNTY IMPACT FEE REVIEW.
  
 PROVIDE ENERGY CALCULATION

Review Stop Z ZONING
Rev No 1 Status P Date 1999-12-13 Cont ID  
Sent By gjoyce Date 1999-12-13 Time 11:45 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***