Plan Review Details - Permit 99120110
Plan Review Stops For Permit 99120110
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2000-02-15 Cont ID  
Sent By dpalmer Date 2000-02-15 Time 11:54 Rev Time 0.00
Received By dpalmer Date 2000-02-15 Time 11:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-01-21 Cont ID  
Sent By dpalmer Date 2000-01-21 Time 07:27 Rev Time 0.00
Received By dpalmer Date 2000-01-21 Time 07:27 Sent To  
Notes
2001-01-08 00:00:00************* PROVISO ****************
  
 1)NOTE: NOW THAT NEW SERVICE IS BEING
 INSTALLED. PLEASE SUBMIT NEW RISER
 DIAGRAM SHOWING SERVICE. TO INCLUDE ALL
 OF THE FOLLOWING: METER, MAIN DISC/MCB.
 ALL CONDUIT SIZES, WIRE SIZES FOR FEEDER
 -S, PLANS SHOW MAIN INSIDE AS EXISTING,,
 IS THIS GOING TO REMAIN? ART;215-5
  
 2)NOTE: PLANS/PANEL SCHEDULE SHOWS 20KW
 OF HEAT BEING FIGURED INTO THE LOAD.???
 PANEL SCHEDULE ONLY SHOW ONE(1) A/C COMP
 AND AIR HANDLER?? IF THERE IS GOING TO
 BE TWO A/C UNITS THEN THEY BOTH NEED TO
 BE ON PANEL SCHEDULE. REQ`D BY NEC ART;
 215-5
  
 3)NOTE:PLEASE LIST THE REQD` DEDICATED
 CIRCUT(S) FOR BATH(S) ON PANEL SCHEDULE.
 AS REQ`D BY 210-52D/ 215-5
  
 4)NOTE: PLEASE CHECK ALL WIRE SIZES FOR
 OVER CURRENT PROTECTION,,,
 A/C COMP AT 2P50 AND HAS #10 AWG,#8 FOR
 AHU MAY NOT BE PROTECTED AT 60 AMPS,THE
 WIRE AMPACITIES MAY ONLY BE USED FROM
 THE 75 DEGREE COLUMN IN ART;310-16
 THE OTHER LOADS FOR POOL PUMP AND HOT
 TUB ARE MOTOR LOADS BUT NAMEPLATE RATING
 SHOULD BE CHECKED FOR MAX. OVERCURRENT
 PROTECTION.
  
 PLEASE HAVE THE ABOVE INFORMATION
 SUBMITTED FOR REVIEW AND APPROVAL BEFORE
 FIRST ROGH ELECTRICALINSPECTION IS
 CALLED IN. IF THERE ARE ANY QUESTIONS
 PLEASE CALL; 659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-01-07 Cont ID  
Sent By dpalmer Date 2000-01-07 Time 08:17 Rev Time 0.00
Received By dpalmer Date 2000-01-07 Time 08:17 Sent To  
Notes
2001-01-08 00:00:00************UNSAT**********************
  
 1)NOTE:AS PER 210-52 MISSING OUTLET
 REQ`D IN BEDROOM #1.
  
 2)NOTE:AS PER ART;210-63 NEED TO HAVE
 OUTLET FOR A/C COND. UNIT.
  
 3)NOTE:AS PER NFPA-72 2-2.1.1.1 SMOKE
 DETECTORS ARE REQ`D INSIDE AND OUTSIDE
 ALL SLEEPING ROOMS OF NEW DWELLINGS.
  
 4)NOTE:AS PER 210-52D BATH GFI NEEDS
 TO BE ON SEPARATE 20AMP #12 AWG CIRCUT.
  
 5)NOTE: AS REQ`D BY 220-3-D-1 NEED TO
 SUBMIT LOAD CALCULATION AND SHOW SIZE OF
 EXISTING SERVICE. PANEL SCHEDULE IS ALSO
 REQ`D SHOWING EXISTING AND NEW .215-5
  
 PLEASE SUBMIT THE ABOVE FOR REVIEW AND
 APPROVAL. IF THERE ARE ANY QUESTIONS
 CALL 659-8096 EXT 8372,.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2000-01-10 Cont ID  
Sent By jcaloger Date 2000-01-10 Time 08:45 Rev Time 0.50
Received By jcaloger Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-01-07 Cont ID  
Sent By tlarge Date 2000-01-07 Time 14:30 Rev Time 0.50
Received By tlarge Date 2000-01-07 Time 14:30 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2000-01-10 Cont ID  
Sent By jcaloger Date 2000-01-10 Time 08:45 Rev Time 0.50
Received By jcaloger Date   Time   Sent To  
Notes
2001-01-08 00:00:00NEEDS IMPACTFEE REVIEW
  
 NEEDS ENERGY CALCU SIGNED
  
 NEEDS PRODUCT APPROVAL FOR WINDOW, DOOR
 AND ROOFING

Review Stop Z ZONING
Rev No 1 Status P Date 1999-12-07 Cont ID  
Sent By gjoyce Date 1999-12-07 Time 13:16 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
2001-01-08 00:00:00ADDITION MUST BE 5' FROM SIDE P/L