| Plan Review Stops For Permit 99110196 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
13 |
Status |
P |
Date |
2002-09-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-09-17 |
Time |
06:38 |
Rev Time |
1.25 |
| Received By |
jwitmer |
Date |
2002-09-17 |
Time |
06:38 |
Sent To |
|
|
| Notes |
| 2002-09-17 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 99110196 | | | ADD: | | | CONT: 6107 S DIXIE HWY | | | TEL: (561)835-1684 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | *****PROVISO***** | | | | | | 1) 1001.1.3 MEANS OF EGRESS SHALL BE | | | CONTINUOUS AND UNOBSTRUCTED PATHS OF | | | TRAVEL TO THE EXTERIOR OF A BUILDING. | | | | | | IT IS CRITICAL THAT THE REQUIRED MEANS | | | OF EGRESS BE DESIGNATED AND MAINTAINED | | | TO INSURE THAT THESE OBSTRUCTIONS ARE | | | ELIMINATED (STORAGE AREAS). | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561)659-8096 X8412 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
12 |
Status |
P |
Date |
2002-09-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-09-08 |
Time |
16:27 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2002-09-08 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2002-09-08 00:00:00 | INTERIOR BUILDOUT | | | INTERIOR BUILD OUT UNIT # 6 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
P |
Date |
2002-08-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-08-28 |
Time |
17:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2002-09-08 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2002-08-28 00:00:00 | | | | BUILDING PLAN REVIEW | | | PERMIT: 99110196 | | | ADD: 6107 S DIXIE HWY | | | CONT: DAAVID LANDY | | | TEL: (305)259-9900 | | | FL BLD CODE= 1997 STANDARD BUILDING CODE | | | | | | *****PROVISO***** | | | | | | 1) IDENTIY TENANT SEPERATION WALLS ABOVE | | | CEILING " FIRE SMOKE BARRIER PROTECT | | | ALL OPENINGS". | | | | | | 2)705.1.2 PENETRATIONS SHALL BE PRO- | | | TECTED BY AN APPROVED PENETRATION FIRE- | | | STOP SYSTEM AS TESTED IN ACCORDANCE WITH | | | ASTM E 814, WITH A MINIMUM POSITIVE | | | PRESSURE DIFFERENTIAL OF 0.01 INCH OF | | | WATER COLUMN AND AN F RATING OF NOT LESS | | | THAN REQUIRED RATING OF THE WALL | | | PENETRATED. PROVIDE MAN. SPEC AT TIME | | | OF INSPECTION. | | | | | | 3) 1203.4.2 EVERY TOLIET ROOM SHALL HAVE | | | WINDOWS AS SPECIFIED FOR HABITABLE ROOMS | | | PROVIDING IN NO CASE LESS THAN 3 SQ FT | | | OPEN SPACE OR HAVE APPROVED EQUIVALENT | | | VENTILATION. NOT SHOWN ON PLAN! | | | | | | 4) REVISION INDICATES FRONT WINDOWS | | | BLOCKED IN, FOR AT TIME OF C. O. | | | | | | 5) 1511.7 ARCHETECT TO INDICATE HOW ROOF | | | TOP MECHANICAL EQUIPMENT IS SECURED TO | | | THE ROOF DECK, EITHER 8" CURB OR RAISED | | | EQUIPMENT WITH A CLEAR HEIGHT OF 18". | | | SHOW ANCHOR DETAIL TO ROOF. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
F |
Date |
2002-08-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-08-23 |
Time |
10:36 |
Rev Time |
2.00 |
| Received By |
jwitmer |
Date |
2002-08-23 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2002-08-23 00:00:00 | | | | BUILDING PLAN REVIEW | | | PERMIT:99110196 | | | ADD: 6107 S DIXIE HWY | | | CONT: DAVID LANDY | | | TEL: (305)259-9900 | | | 1997 STANDARD BUILDING CODE | | | | | | ****REVISION TO BUILDING SHELL PERMIT | | | TO INCLUDE UNIT # 6 AS A BUILD OUT.***** | | | | | | 1) REVISION INDICATES THAT THE WINDOWS | | | HAVE BEEN REMOVED ON THE FRONT OF THE | | | BUILDING WHERE AS BUILDING IS BUILT WITH | | | WINDOWS. | | | | | | 2)704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | | ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | 3)705.7.1 JOINTS INSTALLED IN OR BE- | | | TWEEN FIRE RESISTANT WALLS, FIRE RESIS- | | | TANT FLOORS OR FLOOR/ CEILING ASSEMBLIES | | | AND FIRE RESISTANT ROOFS OR ROOF/ CEIL- | | | ING ASSEMBLIES SHALL BE PROTECTED BY AN | | | APPROVED FIRE RESISTANT JOINT SYSTEM | | | DESIGNED TO RESIST THE PASSAGE OF FIRE | | | FOR A PERIOD NOT LESS THAN THE RE- | | | QUIRED FIRE RESISTANCE RATING OF THE | | | WALL, FLOOR OR FLOOR IN OR BETWEEN | | | WHICH IT IS INSTALLED. | | | | | | 4) PROVIDE UL LISTING OF 1 HR TENANT | | | SEPERATION WALL.704.1.3 | | | | | | 5) LISTED OCCUPANCY: BUSINESS NOT | | | MERCANTILE, OTHERWISE COUNTY SHALL | | | RE- ASSESS IMPACT FEES. | | | | | | 6) TABLE 803.3 MINIMUM INTERIOR FINISH | | | CLASSIFICATION; PROVIDE INFORMATION | | | BASED ON INTERIOR FINISH REQUIREMENTS | | | BASED ON OCCUPANCY | | | | | | 7)11-4.1.2 VERTICAL ACCESSIBILITY, | | | NOTHING IN THIS CODE SHALL BE CONSTRUED | | | TO RELIEVE THE OWNER OF ANY BUILDING, | | | SSTRUCTURE OR FACILITY FROM THE DUTY TO | | | PROVIDE VERTICAL ACCESSIBILITY TO ALL | | | LEVELS ABOVE OR BELOW THE OCCUPIAABLE | | | GRADE LEVEL. EXCEPTION FOR STORAGE 2ND | | | FLOOR, CHAGE OF OCCUPANCY 2ND FLOOR WILL | | | ENVOKE VERTICAL ACCESSIBILITY, INCLUDE | | | NOTE OF EXCEPTION ON PLAN 2ND FLOOR! | | | | | | 8)11-4.1.3(3) GROUND & FLOOR SURFACES | | | ALONG ACCESSIBLE ROUTES & IN ACCESSIBLE | | | ROOMS & SPACES SHALL COMPLY WITH | | | 11-4.5. SEE ADDAAG A4.5.1 (GUIDELINE) | | | A STATIC COEFFICIENT OF FRICTION OF 0.6 | | | IS RECOMENDED FOR ACCESSIBLE ROUTES | | | AND 0.8 FOR RAMPS. NO SCHEDULE? | | | | | | 9)1204.2 SURROUNDING MATERIALS; | | | THE WALLS & FLOORS OF ALL PUBLIC REST- | | | ROOMS SHALL BE LINED WITH NONABSORBANT | | | MATERIALS TO A HEIGTH OF 4'-0" ABOVE THE | | | FLOOR. | | | | | | 10) 1203.4.2 EVERY TOLIET ROOM SHALL | | | HAVE WINDOWS AS SPECIFIED FOR HABITABLE | | | ROOMS PROVIDING IN NO CASE LESS THAN 3 | | | SQ FT OPEN SPACE, OR HAVE APPROVED EQUIV | | | ALENT VENTILATION. | | | | | | 11)1511.7 ROOF MOUNTED MECHANICAL UNIT | | | S SHALL BE MOUNTED ON CURBS RAISED A | | | MINIMUM OF 8 INCHES ABOVE THE ROOF SUR- | | | FACE, OR WHERE ROOFING MATERIALS EXTEND | | | BENEATH THE UNIT, ON RAISED EQUIPMENT | | | SUPPORTS PROVIDING A MINIMUM CLEARENCE | | | HEIGTH OF 18". SHOW ANCHORAGE TO ROOF. | | | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | | ON THE APPLICATION, PLANS, OR ATTACHED | | | SEPARATELY. WHEN RESUBMITTING PLANS | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A | | | DESCRIPTION OF THE REVISION MADE, IDEN- | | | TIFYING THE SHEET OR SPECIFICATION PAGE | | | WHERE THE CHANGES CAN BE FOUND, WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | JIM WITMER | | | PLAN REVIEW | | | TEL: (561)659-8096 EX.8412 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2002-08-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-08-23 |
Time |
08:57 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2002-08-23 |
Time |
08:21 |
Sent To |
|
|
| Notes |
| 2002-08-23 00:00:00 | | | | BUILDING PLAN REVIEW | | | PERMIT: 99110196 | | | ADD: 6107 S DIXIE HWY | | | CONT: DAVID LANDY | | | TEL: (305)259-9900 | | | 1997 STANDARD BUILD CODE | | | | | | ***SHOP DRAWING/ GUARDRAIL/ HANDRAILS*** | | | | | | PROVISO | | | | | | 1015.3(2) A 6" SPHERE SHALL NOT PASS | | | THROUGH THE TRIANGULAR OPENING FORMED | | | BY A TREAD, RISER AND BOTTOM GUARDRAIL. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561)659-8096 X8412 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
F |
Date |
2002-07-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-07-16 |
Time |
09:56 |
Rev Time |
2.00 |
| Received By |
jwitmer |
Date |
2002-07-16 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2002-07-16 00:00:00 | | | | BUILDING PLAN REVIEW | | | PERMIT: 99110196 | | | ADD: 6107 S DIXIE HWY | | | CONT: LANDY CONSTRUCTION | | | TEL: (305) 259-9900 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1)ALL INFORMATION, DRAWINGS, SPECIF- | | | ICATIONS AND ACCOMPANYING DATA SHALL | | | BEAR THE NAME AND SIGNATURE OF THE | | | PERSON RESPONSIBLE FOR THE DESIGN. | | | CITY AMENDMENTS 104.2.1 | | | | | | 2) PLANS, SPECIFICATIONS,REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | 3)FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | THE ORIGINAL PERMIT WAS FOR THE "SHELL" | | | OF THE BUILDING. SEE SHEET 1 BLOCK STAMP | | | BLDG DATE 5/25/01. | | | THE INTERIOR FIT UP CAN BE INCORPORATED | | | UNDER THIS PERMIT, THE ORIGINAL FEES DO | | | HAVE SUFFICIENT FEES FOR THE SHELL + THE | | | TENANT FIT UP. | | | | | | 4) THE ARCHITECT OF RECORD SHALL INCORP- | | | ORATE THE TENANT BUILD OUT DIMENSIONS, | | | RATINGS FOR OCCUPANCY SEPERATION, PLUMB | | | ING,ELECTRICAL,MECHANICAL & BUILDING. | | | BUILDING 1997 SBC | | | ELECTRICAL 1997 NEC/ 99 AMENDMENTS | | | MECHANICAL 1997 MECHANICAL CODE | | | PLUMBING 1994 PLUMBING CODE | | | LIFE SAFETY 1988 AND NEWER | | | | | | ORIGINAL FEES PAID WERE ON A SHELL, | | | ($363000.00) THE VALUE OF THE TOTAL | | | BUILDING UNDER THE 9/16/99 VALUE ARE | | | ($384,086.00) ADDITIONAL FEES OF | | | $561.02 ARE NOW DUE. | | | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | | ON THE APPLICATION, PLANS, OR ATTACHED | | | SEPARATELY. WHEN RESUBMITTING PLANS | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A | | | DESCRIPTION OF THE REVISION MADE, IDEN- | | | TIFYING THE SHEET OR SPECIFICATION PAGE | | | WHERE THE CHANGES CAN BE FOUND, WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | JIM WITMER | | | PLAN REVIEW | | | TEL: (561)659-8096 EX.8412 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2002-05-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-05-29 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2002-05-25 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2002-05-29 00:00:00 | STAIR DETAILS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2001-05-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-05-25 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2001-05-25 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2001-05-25 00:00:00 | PROVISO:GLAZED OPENINGS WILL REQUIRE | | | PRODUCT APPROVAL FOR LARGE MISSLE | | | IMPACT TESTING. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2001-05-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-05-07 |
Time |
18:39 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2001-05-07 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2001-05-07 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT # 99110196 | | | 6107 S DIXIE HWY | | | | | | 1)- DISCREPANCY SHEET A-2 NOTES THAT ALL | | | SECOND STORY STAIRWELL DOORS HAVE A 1 HR | | | RATING, THIS DOOR IS (2) BUT THE SAME | | | DOOR (2) IS INDICATED FOR THE RESTROOMS | | | ON THE FIRST FLOOR. | | | | | | 2)- STORAGE & MERCANTILE TO HAVE (1 HR) | | | SEPERATION SHOW U.L. RATING FOR THE | | | CEILING FLOOR ASSEMBLY. | | | | | | 3)- SHEET A-2 DEPICTS THE OCCUPANCY TO | | | BE STORAGE, SBC TABLE 1604.1 STORAGE | | | LIGHT THE FLOOR LOADING IS TO BE 125 LBS | | | LIVE LOAD. | | | | | | 4)- ADMINISTRATIVE CODE 106.4 .2. | | | STORAGE & FACTORY OCCUPANCIES. IT SHALL | | | BE THE RESPONSIBILITY OF THE OWNER, | | | AGENT, PROPRIETOR OR OCCUPANT OF GROUP S | | | OR GROUP F OCCUPANCIES, TO EMPLOY A COMP | | | ETENT ARCHITECT OR ENGINEER IN COMPUTING | | | SAFE LOAD CAPACITY.ALL SUCH COMPUTATIONS | | | SHALL BE ACCOMPANIED BY AN AFFIDAVIT | | | FROM THE ARCHITECT OR ENGINEER STATING | | | THE SAFE FLOOR LOADS ON EACH FLOOR IN | | | POUNDS PER SQUARE FOOT UNIFORMLY DISTRIB | | | UTED. THE COMPUTATIONS AND AFFIDAVITE | | | SHALL BE FILED AS A PERMANENT RECORD OF | | | THE BUILDING DEPARTMENT. | | | | | | 5)- ADMINISTRATIVE CODE 106.4.3 | | | SIGNS REQUIRED FOR EVERY PART OF THE | | | BUILDING THAT WILL BE USED FOR STORAGE. | | | THE SIGNS SHALL STATE TTTHE SAFE FLOOR | | | LOADS AS REVIEWED BY THE BUILDING DEPART | | | MENT WHICH BE SUPPLIED & SECURELY | | | AFFIXED BY THE OWNER OF THE BUILDING IN | | | A CONSPICUOUS PLACE IN EVERY STORY TO | | | WHICH THEY RELATE. | | | | | | 6)- SBC 1606.2.6.2 COMPONENTS & CLADDING | | | THE INFORMATION SUBMITTED ON THE FRONT | | | DOORS SI FOR SMALL MISSLE IMPACT ONLY, | | | THE CITY REQUIRES TESTING FOR LARGE | | | MISSLE IMPACT TESTING,2 COPIES FOR EACH | | | PRODUCT. DADE COUNTY OR S.B.C.C.I. | | | REPORT ARE ACCEPTED. THIS CAN BE A | | | "PROVISO" TO BE SUBMITTED BEFORE THE | | | FIRST INSPECTION. | | | | | | 7)- THE ROOFING CUT SHEET WILL BE ACCEPT | | | ABLE TO SHOW IT COMPLIES TO THE REQUIRE- | | | MENTS OF THE FIRE DISTRICT. WE ALSO NEED | | | PRODUCT TESTING FOR 110 MPH WIND ZONES | | | SBC 1503..3.2/1503.4.1.2.DADE COUNTY OR | | | SBCCI REPORT ARE ACCEPTABLE,THIS COULD | | | ALSO BE A "PROVISO" TO BE SUBMITTED AS A | | | SEPERATE PERMIT. | | | | | | 8)- SUBMIT PLANS TO COUNTY FOR IMPACT | | | FEES, IF THERE WAS A STRUCTURE THERE | | | BEFORE THERE MAY BE A CREDIT DUE FOR THE | | | DEMO. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | 659-8096 EX 8412 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2001-02-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-02-20 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2001-02-20 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2001-02-20 00:00:00 | PERMIT # 99110196 | | | 6107 S. DIXIE HWY. | | | CINQUE PROPERTIES | | | | | | 1)- THE SURVEY & TAX RECORDS DECLARE | | | THESE TO BE SEPERATE LOTS. A UNITY OF | | | TITLE NEEDS TO BE RECORDED TO BUILD THE | | | PROPOSED STRUCTURE ON THESE LOTS. THE | | | CONTACT PERSON TO SEE WOULD BE | | | ANGELLA JONES (SENIOR PLANNER) IN THE | | | ZONING DEPARTMENT.659-8031. | | | 2)- THE NEW SURVEY DOESN'T DEPICT THE | | | NEW BUILDING LOCATION. THE SITE PLAN | | | DOESN'T GIVE THE DIMENSION FROM THE REAR | | | OF THE BUILDING TO THE PROPERTY LINE. | | | THIS INFORMATION IS CRITICAL IN DETER- | | | MINING THE RATING ON THE EXTERIOR WALLS | | | AS WELL AS THE % OF OPENINGS ALLOWED. | | | STANDARD BUILDING CODE TABLE 600 | | | (HORIZONTAL SEPERATION) REQUIRES 0-3' | | | 3 HR. WALLS/ 0 OPENINGS. 3' TO 10' ALLOW | | | FOR A 2 HR. WALL & 10 % OPENINGS. SEE | | | NOTE "B" PARAPETS 704.5 THIS IS THE WALL | | | DEPICTED WITH "NO PARAPET SO THE ROOF | | | DRAINAGE WAS TO CASCADE OVER THIS WALL. | | | ROOF DRAINAGE WILL NEED TO BE ADDRESSED | | | WITH SCUPPERS AND OVERFLOWS. | | | 3)- TABLE 600 THE SOUTHELEVATION OF | | | THE PROPOSED NEW CONSTRUCTION VS THE | | | EXISTING BUILDING 1,421 SQ. FT. AN | | | ASSUMED PROPERTY LINE NEEDS TO BE ESTAB- | | | LISHED BETWEEN THE 2 STRUCTURES. THEN WE | | | LOOK AT WHAT WALL RATINGS AND % OF OPEN- | | | INGS, AND OPENING PROTECTIVES WOULD MEET | | | THE TABLE 600 REQUIRMENTS. ATTACHED IS A | | | EXAMPLE FROM THE COMMENTARIES SHOWING A | | | BUILDING 45% TO THE PROPERTY LINE, THIS | | | SHOULD HELP IN DETERMINING WALL RATINGS | | | AND OPENING PROTECTIVES.REMEMBER TABLE | | | 600 NOTE "B" ON PARAPETS, 3'-0" ABOVE | | | THE ROOF LINE. | | | 4)_ SOILS INVESTIGATION REPORT: A COPY | | | OF THE COUNTYWIDE AMENDMENTS IS ATTACHED | | | THE STUCTURAL PLANS FOUNDATION NOTES | | | DESCRIBE A TESTING REPORT THAT THEIR | | | DESIGN WAS BASED ON, (DUNKLEBERGER ENG & | | | TESTING, DATED NOV.30, 2000). THIS IS | | | THE REPORT CONTAINING THE INFORMATION | | | THAT THE CITY HAS BEEN ASKING FOR. | | | 5)- TRAVEL DISTANCE IS MEASURED FROM THE | | | MOST REMOTE POINT TO THE EXIT, INCLUDING | | | THE 2ND FLOOR STORAGE. THE USAGE OR | | | OCCUPANCY OF THE BUILDING WILL BE RETAIL | | | OR BY OCCUPANCY: MERCANTILE. THE MAXIMUM | | | DISTANCE THAT APERSON COULD TRAVEL | | | WITH THE SINGLE EXIT ON THE SECOND FLOOR | | | IS 50'-0". THE SECOND ISSUE IS THE PRO- | | | TECTION OF THE EXIT STAIRWAY.SBC1006.1.1 | | | EXIT STAIRWAYS BETWEEN FLOORS SHALL BE | | | ENCLOSED IN OR SEPERATED BY FIRE RESIS- | | | TANT CONSTRUCTION IN ACCORDANCE WITH | | | 705.2 & TABLE 705.1.2. SBC 705.2.1.1 | | | PROTECTION OF FLOOR OPENINGS SHALL BE | | | PROVIDED IN ACCORDANCE WITH THESE PRO- | | | VISIONS TO PREVENT THE SPREAD OF FIRE | | | FROM STORY TO STORY. THE EXIT SHALL BE | | | RATED TO THE EXTERIOR OF THE BUILDING. | | | THE THIRD ISSUE IS THE OCCUPANCY SEPERA- | | | TION BETWEEN THE FIRST FLOOR (MERCAN- | | | TILE- 1 HR) AND THE (STORAGE OCCUPANCY | | | 2 HR) ON THE SECOND FLOOR. | | | 6)- FIRE DISTRICT: 102.2.5 IN BUILDINGS | | | 2 STORIES OR MORE IN HEIGTH ALL WALLS, | | | FLOORS, ROOFS AND THEIR SUPPORTING | | | STRUCTURAL MEMBERS SHALL PROVIDE NOT | | | LESS THAN 1 HR. FIRE RESISTANCE. SHOW | | | UL LISTINGS FOR THESE COMPONENTS. | | | 7)- SECOND FLOOR LIVE LOAD NOTED ON | | | A-5.0 AS "60 LBS. LIVE".SBC TABLE 1604.1 | | | FOR THE LIVE LOADS FOR THE SECOND FLOOR | | | ARE 125 LBS FOR LIGHT STORAGE.PLEASE | | | HAVE THE STRUCTURAL ENGINEER REVISIT HIS | | | CALCULATIONS FORTHIS ADDITIONAL LOADING. | | | 8)- GUARDRAIL DETAILS: A5.1 THE STAIR | | | HANDRAIL/ GUARDRAIL DETAIL NEEDS TO | | | COMPLY WITH SBC 1015.3, A 4" SPHERE TO N | | | OT BE ABLE TO PASS THROUGH THE UPRIGHTS. | | | 9)- FL ACCESSIBILITY CODE 4.9.4.1 A CON- | | | TINIOUS HANDRAIL ON BOTH SIDES OF THE | | | STAIRS, EXTEND 12" BEYOND THE TOP RISER | | | & 12" PLUS THE WIDTH OF ONE TREAD BEYOND | | | THE BOTTOM RISER. | | | 10)- VERTICAL ACCESSIBILITY: NOTE: | | | WHENEVER THE CHANGE OF OCCUPANCY ON THE | | | SECOND FLOOR (STORAGE) IS CHANGED TO A | | | HABITABLE OCCUPANCY,VERTICAL ACCESSIBIL- | | | ITY WILL BE REQUIRED. THERE IS NO 20% | | | DISPROPORTIONATE COST INVOLED.THIS NOTE | | | WILL APEAR ON THE PLANS. | | | 11)- SBC 1606.2.6.2 COMPONENENTS & CLAD- | | | DING, THE INFORMATION SUBMITTED ON THE | | | FRONT DOOR IS FOR SMALL MISSLE IMPACT | | | TESTING ONLY. A COPY OF THE CITY'S | | | POLICY FOR GLAZED OPENINGS IS INCLUDED | | | FOR TESTING REPORTS THAT HAVE NOT | | | RECEIVED SBCCI APPROVAL OR DADE COUNTY | | | APPROVAL, THE REPORT HAS TO BE SITE | | | SPECIFIC AND THE SEALED BY THE MANUFAC- | | | TURES ENGINEER AS WELL AS THE ENGINEER | | | OF RECORD FOR THE PROJECT. THE CITY WILL | | | ALSO REQUIRE SEPERATE REPORTS FOR THE | | | OTHER DOORS ,WINDOWS, SHUTTERS& ROOFING. | | | 12 )- SBC-F102.2.4: FIRE DISTRICT THE | | | ROOF COVERINGS IN THE FIRE DISTRICT | | | SHALL CONFORM TO THE REQUIREMENTS OF A | | | CLASS "A" OR "B" ROOF COVERINGS. THE | | | SPECS SUBMITTED ARE NOT HIGH LIGHTED OR | | | SPECED OUT WHAT THEY ARE GOING TO USE? | | | 13).1997 FL ENERGY CODE 400 ENERGY CODE | | | REQUIREMENTS FOR THE SHELL OF THE BUILD- | | | ING. | | | 14)- DISCREPANCIES: THE ARCH. PLANS VS. | | | THE STRUC. PLANS THE STRUCTTUTRAL | | | DETAILS DO NOT MATCH,FRAMING, TRUSSES, | | | BAR JOIST ETC. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561) 659-8096 EX 8412. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2000-08-17 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-08-17 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2000-08-17 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | BUILDING REVIEW COMMENTS | | | -------------------------- | | | DEAR MR.FAGAN, | | | RESPONSE TO YOUR LETTER OF JULY 12,2000, | | | ITEMS NOTED 1 THRU 11, | | | | | | 1]1987 SURVEY PROVIDED IS NOT CONSIDERED | | | CURRENT,PLEASE PROVIDE SIGNED AND | | | SEALED COPY DATED WITHIN 2 YEARS. | | | 2]COMPLIANCE WITH TABLE 600[SBC] HAS NOT | | | BEEN ACHIEVED. | | | 3]SOIL INVESTIGATION REPORT WAS NOT | | | PROVIDED. | | | 4] OK | | | 5]TRAVEL DISTANCE IS MEASURED THE MOST | | | REMOTE POINT TO THE EXIT,INCLUDING THE | | | 2ND FLOOR STORAGE. | | | 6]STRUCTURAL DESIGN ENGINEER SHALL | | | SUBMIT CALCULATIONS FOR ALL LOAD | | | BEARING CONDITIONS. | | | 7]STAIR DETAIL IS NOT COMPLETE,SUBMIT | | | GUARDRAIL AND HANDRAIL DETAILS COMPLY | | | WITH 1007[SBC]. | | | 8]DETAIL PARAPET SUPPORTS. | | | 9]SUBMIT PRODUCT TESTING FOR DOORS AND | | | WINDOWS,ROOF COVERING AND STORM | | | SHUTTERS. | | | 10]IMPACT AND RADON FEES DUE. | | | | | | | | | REVIEWED BY; | | | LUIS MARTINEZ | | | 659-8096#8456 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2000-06-03 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-06-03 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2000-06-03 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | BUILDING-STRUCTURAL | | | --------------------- | | | | | | 1]PROVIDE A CURRENT SIGNED AND SEALED | | | SURVEY. | | | 2]SUBMIT DETERMINATION OF CONSTRUCTION | | | TYPE,SEE TABLE 600[97SBC]FOR EXTERIOR | | | WALL REQUIREMENTS,ALSO APPENDEX"F". | | | 3]PROVIDE SOIL INVESTIGATION INFORMATION | | | [SITE WAS PREVIOUSLY SERVICE STATION]. | | | 4]PROVIDE ACCESSIBILITY TO 2ND LEVEL, | | | MAIN ENTRENCE DOORS ARE NOT ACCESSIBLE | | | DOOR REQUIRES A MINIMUM OF 18 INCHES | | | CLEARENCE AT THE PULL SIDE OF HANDLE. | | | 2'8"DOORS AT RESTROOMS WILL NOT COMPLY | | | WITH 32"CLEAR REQUIREMENT. | | | 5]1027[97SBC]SINGLE EXIT REQUIREMENT NOT | | | IN COMPLIANCE TRAVEL DISTANCE[MAX.50'] | | | PROVIDE 2ND EXIT FROM EACH SPACE. | | | 6]HAVE STRUCTURAL ENGINEER SUBMIT DESIGN | | | CRITERIA FOR THE MASONRY AND THEIR | | | CONNECTIONS,SOUTH WALL IS MISSING | | | COLUMNS,PROVIDE WALL SECTIONS FOR IN- | | | TERIOR WALLS,SUBMIT FLOOR LOAD CALCUL- | | | ATIONS FOR STORAGE OCCUPANCY SEE 1604 | | | [97SBC],SUBMIT ROOF DRAINAGE PLAN. | | | 7]PROVIDE COMPLETE STAIR DETAILS. | | | 8]GIVE DIMENSIONS ON ELEVATIONS INCLUDE | | | PARAPETS AND DETAIL THEIR SUPPORTS. | | | 9]SUBMIT SPECIFICATIONS FOR | | | ARCHITECTURAL TRIM,AND TEST REPORTS | | | FOR EXTERIOR WINDOWS,DOORS AND ROOF | | | COVER. | | | 10]COUNTY IMPACT AND CITY RADON FEES ARE | | | DUE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
1999-12-28 |
|
|
Cont ID |
|
| Sent By |
jcaloger |
Date |
1999-12-28 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2000-06-03 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PLANS DO NOT PROVIDE SUFFICIENT CONSTRU- | | | CTION INFORMATION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2002-09-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-09-04 |
Time |
12:29 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2002-09-04 |
Time |
12:29 |
Sent To |
FIRE |
|
| Notes |
| 2002-09-04 00:00:00 | PLANS RDLINED FOR EGRESS LIGHTING IN | | | ROOMS.210-70. OK DV PALMER. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2002-08-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-08-22 |
Time |
12:57 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2002-08-22 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2002-08-22 00:00:00 | *************** UNSAT ************** | | | | | | 1)NOTE: PLEASE NOTE THAT ALL HAND DRAWN | | | CHANGES ON PLANS MUST EACH BE SIGNED | | | AND DATED BY THE ARCH OF RECORD AT EACH | | | LOCATION. THIS IS FS/FAC REQ`MENT | | | 481.221 | | | | | | 2)NOTE: PLEASE NOTE PLANS ARE STILL | | | MISSING EM /EXIT LTS. AS REQ`D. | | | | | | 3)NOTE: PLEASE NOTE PLANS MISSING SOME | | | SWITCHING CONTROL FOR LIGHTS. | | | PLEASE SEE FIRE REVIEW COMMENTS FOR | | | EXIT AND EM LT LOCATIONS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. IF A MEETING IS PREFERRED | | | TO GET ALL ITEMS ON THE TABLE AT THE | | | SAME TIME PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2002-07-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-07-23 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-07-23 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2002-07-23 00:00:00 | **************** UNSAT ************** | | | | | | 1)NOTE: PLEASE NOTE THAT THERE IS NOT | | | ENOUGH ELECTRICAL INFORMATION FOR | | | COMPLETE REVIEW. PLEASE ALSO NOTE THAT | | | MORE ELECTRICAL IS REQ`D. | | | | | | 2)NOTE: PLEASE NOTE THAT PLANS ARE REQ`D | | | TO BE DONE BY THE ORIG ARCH/ENGINEER | | | OF RECORD.471.025/481.221 FS. | | | | | | 3)NOTE: PLEASE NOTE THAT IF LEFT AS A | | | REVISION, ALL REVIEWS TO BE DONE UNDER | | | 99 NEC AND 99 LOCAL AMENDMENTS. | | | | | | PLEASE SUBMIT THE ABOVE CORRECTIONS FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2001-04-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-04-27 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-04-27 |
Time |
12:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2001-02-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-02-27 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-02-27 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2001-02-27 00:00:00 | ****************** UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE SHEET E1.0, PLANS | | | SHOW SEPARATE SERVICES BETWEEN THE TWO | | | CENTER BAYS , PLEASE SHOW CLARIFICATION | | | ON TENANT SEPARATION. PLANS DON'T | | | SHOW THE REQ`D TWO(2) HR FIRE WALL UP TO | | | ROOF DECK. 230-2.230-72 | | | | | | 2)NOTE: PLEASE SEE E-1.0 PLANS HAVE BOTH | | | 1ST AND 2ND FLOOR LABELED 2ND FLOOR?? | | | PLEASE CORRECT. | | | | | | 3)NOTE: PLEASE PROVIDE CLARIFICATION | | | FOR MAINS, PANELS ARE SHOWN AS HAVING | | | MCB AND YET THERE ARE MAIN DISCONNECTS | | | ON OUTSIDE OF BLDG.??WHICH ONE OR IS IT | | | BOTH? | | | | | | 4)NOTE: PLEASE PROVIDE CLARIFICATION | | | FOR MEANS OF EGRESS LIGHTING FOR STAIR | | | TRAVEL UP AND DOWN? 3-WAY SWITCHES???? | | | | | | 5)NOTE: PLEASE NOTE PER LOCAL AND COUNTY | | | WIDE CODE, OUTLET SPACING IS TO MEET | | | 20` OF WALL,INSTORAGE SPACE 210-50 | | | | | | 6)NOTE:PLEASE SHOW BRANCH CIRCUIT #`S | | | ON PLANS THAT CORRELATE TO SUBMITTED | | | PANEL SCHEDULES. | | | | | | 7)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | | | 8)NOTE: PLEASE NOTE EQUIPMENT GROUNDING | | | CONDUCTOR REQ`D AFTER FIRST MEANS OF | | | DISCONNECT. 250-122 | | | | | | 9)NOTE PLEASE SHOW ALL SERVICE CONDUCTOR | | | -S RISER/METER ECT. 215-5 | | | | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2000-08-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-08-02 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-08-02 |
Time |
11:23 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ************** UNSAT ******************* | | | | | | 1)NOTE: NOTES STILL NOT ADDRESSED??????? | | | | | | CALLED AND LEFT MESSAGE FOR RETURN CALL | | | FOR EXPLANATION. | | | | | | 2)NOTE: SUBMIT LOAD CALCULATIONS UNDER | | | ART;220 OF THE NEC. | | | SHOW ALL CONTINUOUS LOADS AT 125% ETC. | | | STILL MISSING ELECTRICAL REQ`D FOR | | | SECOND FLOOR MISSING FROM E-DRAWINGS. | | | | | | | | | PLEASE SUBMIT ALL THE INFORMATION ASKED | | | FOR FROM PREVIOUS NOTES AND THESE NOTES. | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2000-05-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-05-26 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-05-26 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SAME AS FIRST SET OF NOTES. | | | IT APPEARS THAT NO CHANGES HAVE BEEN | | | MADE. | | | PLEASE SUBMIT THE INFORMATION ON ORIG. | | | NOTES FOR REVIEW, IF THERE ARE ANY | | | QUESTIONS PLEASE CALL 659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
1999-12-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
1999-12-07 |
Time |
06:18 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
1999-12-07 |
Time |
06:18 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************UNSAT******************** | | | | | | 1)NOTE:SUBMIT AIC RATING OF ALL | | | EQUIPMENT MAINS/BRKRS ETC. AS PER 110-9 | | | 215-5 | | | | | | 2)NOTE:AS PER 250-81 BLDG.STEEL IS ALSO | | | TO BE INCLUDED AS PART OF THE GROUNDING | | | ELECTRODE SYSTEM. | | | | | | 3)NOTE:SHOW SECOND FLOOR ON PLANS AS | | | EITHER EXISTING OR FUTURE. | | | | | | 4)NOTE:PLANS DO NOT CORRELATE WITH | | | EACHOTHER. THE ONE SMALL SET ATTACHED TO | | | FRONT OF PLANS SHOW ALL MAIN DISCS BEING | | | GROUPED FROM MAIN SERVICE. PLANS FROM | | | E-1.0 SHOW SEPARATE METERS,DISCS ON THE | | | BACK OF EACH UNIT???? WHICH ONE ????? | | | | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF ANY QUESTIONS,,,, | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
5 |
Status |
P |
Date |
2001-05-23 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2001-05-23 |
Time |
10:39 |
Rev Time |
2.00 |
| Received By |
mamini |
Date |
2001-05-23 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2001-05-23 00:00:00 | PASSED WITH PROVISOS: | | | 1. PER OUR MEETING WITH THE OWNER AND | | | THE ARCHITECT, H.C PARKING SHOULD BE | | | RELOCATED IN ORDER TO PROVIDE MINIMUM OF | | | 3'- 0" WIDTH ROUTE TO BUILDINGS AND IT | | | SHOULD INCLUDE A MINIMUM OF 60" ACCESS | | | AISLE. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
4 |
Status |
F |
Date |
2001-04-27 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2001-04-27 |
Time |
09:27 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2001-04-27 |
Time |
08:57 |
Sent To |
|
|
| Notes |
| 2001-04-27 00:00:00 | FAILED: | | | 1. PLEASE REFER TO PREVIOUS REVIEW | | | COMMENTS DATED 3/7/01. | | | IF ANY QUESTION PLEASE CONTACT 561-659- | | | 8096 EXT. 8492 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
F |
Date |
2001-03-07 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2001-03-07 |
Time |
09:42 |
Rev Time |
2.00 |
| Received By |
mamini |
Date |
2001-03-07 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2001-03-07 00:00:00 | FAILED: | | | DUMPSTER ENCLOSURE MUST BE CONSTRUCTED | | | PER CITY OF WPB STANDARD.DESIGNER TO | | | CONSIDER SAFETY WHEN LOCATING THE | | | DUMPSTER SITE.THE OPENING OF THE | | | DUMPSTER ENCLOSURE MUST BE ANGLED SO | | | THAT A 40' LONG TRUCK WITH THE FORKS | | | EXTENDED CAN APPROACH THE OPENING | | | WITHOUT TURNING A SHARP TURN OR | | | INTERRUPTING THE FLOW OF TRAFFIC.SEE | | | ATTACHED STANDARD | | | 2. ALL DRIVEWAY APPROACHES MUST BE | | | CONSTRUCTED PER CITY OF WPB STANDARD. | | | SEE ATTACHED STANDARD | | | 3. ALL BROKEN SIDEWALK, CURB (& GUTTERS) | | | ALONG THE PROPERTY (ALL SIDES) MUST BE | | | REPLACED. | | | 4. PROVIDE POLLUTION PREVENTION PLAN AS | | | STATED IN PREVIOUS REVIEW AND SHOW | | | DETAILS.ALSO SHOW TRUCK WASHOUT AREA | | | FOR TRUCK LEAVING THE SITE DURING | | | CONSTRUCTION. | | | 5. PROVIDE DETAILS FOR WATER, SANITARY, | | | SANITARY CLEAN OUT, IRRIGATION.ALSO | | | SHOW THE LOCATIONS. | | | 6. SHOW DETAILS FOR STORM WATER | | | STRUCTURES AND TYPE USED. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2000-05-24 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2000-05-24 |
Time |
14:57 |
Rev Time |
2.00 |
| Received By |
mgonzale |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | FAILED SINCE IN PREVIOUS REVISION | | | A UNITY OF TITLE IS REQUESTED AND IT | | | HAS NOT BEEN PROVIDED. | | | | | | ON THE PAVING AND DRAINAGE PLAN | | | PERVIOUS AND IMPREVIOUS CALCULATIONS | | | MUST BE PROVIDED. | | | | | | A POLLUTION CONTROL PLAN MUST BE | | | SUPPLIED ASWELL. | | | | | | ALL COMMENTS ON STORM WHERE PROVIDED | | | ON PREVIOUS SUBMITTAL. | | | | | | THIS PERMIT HAS BEEN DESCRIBED AS | | | "NEW CONSTRUCTION OF STRUCTURE ONLY" | | | | | | NO DUMPSTER DETAIL HAS BEEN PROVIDED. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
1999-12-27 |
|
|
Cont ID |
|
| Sent By |
dlauderm |
Date |
1999-12-27 |
Time |
09:25 |
Rev Time |
0.50 |
| Received By |
mgonzale |
Date |
1999-12-27 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | FAILED.NEED THE FOLLOWING INFORMATION | | | SUPPLIED: | | | NEED UNITY OF TITLE FOR PROPERTY TO THE | | | NORTH (LOTS 1 & 2) WITH THIS PROPERTY. | | | OWNER WANTS TO CROSS IT FOR WATER AND | | | SANITARY HOOK-UPS. | | | STORM WATER REQUIREMENTS: | | | TO OBTAIN A CONSTRUCTION PERMIT THE | | | FOLLOWING MUST BE SUBMITTED SIGNED AND | | | SEALED BY A FLORIDA PROFESSIONAL | | | ENGINEER (PE). | | | 1. CONSTRUCTION PLANS | | | 2. DETAILS AND SPECIFICATIONS | | | 3. HYDRAULIC COMPUTATIONS AND SUPPORTING | | | DOCUMENTATION | | | 4.IMPERVIOUS AREA COMPUTATIONS | | | 5.POLLUTION PREVENTION PLAN.THE | | | POLLUTION PREVENTION PLAN SHALL BE KEPT | | | ON SITE AT ALL TIMES DURING | | | CONSTRUCTION. THE PLAN SHALL BE | | | INSTALLED IN THE FIELD PRIOR TO ANY | | | EARTHWORK. THE ENGINEER OF RECORD SHALL | | | CERTIFY TO THE CITY, ON A MONTHLY BASIS, | | | THAT THE PLAN IS WORKING PROPERLY AND AS | | | DESIGNED. THE ENGINEER OF RECORD IS | | | RESPONSIBLE TO CERTIFY IMPLEMENTATION | | | OF THE PROVISIONS OF CITY ORDINANCE NO. | | | 3132-98 OF THE CITY CODE AT SUCH TIME | | | THE PERMITTEE APPLIES FOR A CERTIFICATE | | | OF OCCUPANCY FROM THE CITY BUILDING | | | OFFICIAL. | | | 6.EVERY SIX MONTHS AFTER CONSTRUCTION A | | | PE SHALL CERTIFY THAT THE PERMANENT | | | POLLUTION PREVENTION STRUCTURES, DRY-WET | | | WATER DETENTION FACILITIES, AND | | | EXFILTRATION SYSTEMS ARE WORKING AS | | | DESIGNED AND ARE IN GOOD OPERATING | | | CONDITION. ALL CERTIFICATIONS MUST BE | | | SUBMITTED TO: | | | STORM WATER UTILITY ENGINEER | | | CITY OF WEST PALM BEACH PUBLIC UTILITIES | | | DEPARTMENT | | | P.O. BOX 3366, WEST PALM BEACH, FL 33402 | | | THE CERTIFICATION MUST INCLUDE THE | | | BUILDING PERMIT NUMBER, THE ADDRESS OF | | | THE PROPERTY AND THE NAME OF THE | | | ESTABLISHMENT/PROJECT CONSTRUCTED. | | | NO DUMPSTER SITE SHOWN.MUST MEET THE | | | FOLLOWING; | | | GARBAGE PICK-UP: | | | STATE IF GARBAGE IS TO BE PICKED UP BY | | | CITY OR IF IT IS PRIVATE PICKUP, IF TO | | | BE PICKED UP BY THE CITY THEN THE | | | FOLLOWING REQUIREMENTS MUST BE MET: | | | 1.DUMPSTER MUST HAVE A MINIMUM OF 12'-6" | | | OPENING BETWEEN THE GATE POSTS. | | | 2.INTERIOR DIMENSIONS OF THE ENCLOSURE | | | MUST BE A MINIMUM OF 12'-6" WIDE AND 12' | | | DEEP.A CONCRETE PARKING STOP BARS 10' | | | LONG MUST BE CENTERED (FROM GATES) AND | | | INSTALLED 18" FROM THE BACK WALL. | | | STEEL BARS WILL BE DRILLED THRU THE STOP | | | BAR AND INTO THE INTERIOR FLOOR OF THE | | | ENCLOSURE TO STOP THE BAR FROM MOVING | | | WHEN THE DUMPSTER IS SET INSIDE. | | | 3.THE OPENING OF THE DUMPSTER ENCLOSURE | | | MUST BE ANGLED SO THAT A 40' LONG TRUCK | | | WITH THE FORKS EXTENDED CAN APPROACH THE | | | OPENING AND PICK UP THE DUMPSTER WITHOUT | | | TURNING A SHARP TURN. | | | 4.THE TRUCK NEEDS TO HAVE NO LESS THAN A | | | 16' HIGH VERTICAL CLEARANCE AREA FOR THE | | | TRUCK TO PICK UP THE DUMPSTER. THE CLEAR | | | AREA MUST OVER THE DUMPSTER AND WHERE | | | THE TRUCK WILL BE STOPPED TO UNLOAD THE | | | DUMPSTER. | | | 5.THE TRUCK NEEDS TO HAVE NO LESS THAN | | | 14' HIGH VERTICAL CLEARANCE AND 12' | | | HORIZONTAL CLEARANCES FOR THE TRUCK TO | | | DRIVE THROUGH. | | | 6.IT IS STRONGLY SUGGESTED THAT YOU ADD | | | A RECYCLING CENTER TO YOUR DUMPSTER | | | ENCLOSURE. | | | 7.SEE ATTACHED STANDARD DETAIL FOR | | | FURTHER INFORMATION. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
7 |
Status |
P |
Date |
2002-09-17 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-09-17 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-09-17 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2002-09-17 00:00:00 | 1) MEANS OF EGRESS SHALL BE MAINTAINED | | | AT ALL TIMES. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
6 |
Status |
P |
Date |
2002-09-05 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-09-05 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-09-05 |
Time |
13:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
F |
Date |
2002-08-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-09-04 |
Time |
12:31 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-08-22 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2002-08-22 00:00:00 | 1) PLANS DO NOT INDICATE EMERGENCY | | | LIGHTS OR EXIT SIGNS. | | | | | | 2) NO DETAILS ON HOW THE WALLS WILL | | | BE CONSTRUCTED. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2001-05-16 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-05-16 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-05-16 |
Time |
08:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2001-04-26 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-04-26 |
Time |
07:55 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-04-26 |
Time |
07:55 |
Sent To |
|
|
| Notes |
| 2001-04-26 00:00:00 | 1) NOTE ON SECOND FLOOR INDICATES | | | TYPICAL ONE HOUR DOOR WITH CLOSURE. | | | DOOR SCHEDULE INDICATES 02 DOORS | | | WITHOUT A RATING PLEASE CORRELATE. | | | 2) STORAGE AND MERCANTILE OCCUPANCIES | | | TO BE SEPARATED FROM ONE ANOTHER BY | | | AT LEAST ONE HOUR FIRE SEPARATION. | | | 3) EXIT SIGNS AND EMERGENCY LIGHTING | | | NEEDED ON SECOND FLOORS. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2001-03-06 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-03-06 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-03-06 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2001-03-06 00:00:00 | 1) EXISTING FIRE HYDRANTS NOT SHOWN ON | | | SITE PLAN. | | | 2) BUILDING ADDRESS NOT SHOWN ON | | | ELEVATION DRAWINGS. BUILDING ADDRESS TO | | | COMPLY WITH CITY CODE REQUIREMENTS. | | | 3) IN CLASS C MERCANTILE OCCUPANCIES, | | | A MINIMUM OF TWO EXITS ARE REQUIRED. | | | ADDITIONAL EXIT SIGNS ARE REQUIRED ABOVE | | | REAR EXIT DOORS. | | | 4) IF SECOND FLOOR IS USED FOR STORAGE, | | | IT MUST BE SEPARATED BY AT LEAST ONE | | | HOUR FROM THE FIRST FLOOR AND ALL | | | OPENINGS MUST BE PROTECTED WITH RATED | | | FIRE DOORS EQUIPPED WITH SELF-CLOSING | | | DEVICES. | | | 5) NO INTERIOR FINISH INFORMATION | | | PROVIDED WITH PLANS. | | | 6) TENANT SEPARATIONS TO COMPLY WITH | | | BUILDING CODE REQUIREMENTS. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
1999-12-03 |
|
|
Cont ID |
|
| Sent By |
rturnque |
Date |
1999-12-03 |
Time |
09:31 |
Rev Time |
0.20 |
| Received By |
rturnque |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2002-05-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-05-06 |
Time |
11:00 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2002-05-06 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2002-05-06 00:00:00 | MECHANICAL PERMIT 02031921 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
N |
Date |
2001-05-09 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-05-09 |
Time |
12:14 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2001-05-09 |
Time |
12:04 |
Sent To |
|
|
| Notes |
| 2001-05-09 00:00:00 | ********************DENIED************** | | | | | | INSUFFICIENT INFORMATION FOR MECHANICAL | | | REVIEW, PLEASE PROVIDE PLANS WITH | | | MECHANCIAL PERMIT APPLICATION. | | | | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT | | | PATTY KRAUSS AT 659-8096EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2001-02-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-02-22 |
Time |
15:48 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2001-02-22 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2001-02-22 00:00:00 | ****************DENIED****************** | | | | | | NO MECHANICAL PLANS SUBMITTED.SUBMIT P | | | LANS WITH MECHANICAL PERMIT APPLICATION. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2000-07-25 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-07-25 |
Time |
11:04 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-07-25 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | UNSAT: | | | NO MECHANICAL PLANS SUBMITTED FOR REVIEW |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
1999-12-15 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
1999-12-15 |
Time |
06:50 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
1999-12-15 |
Time |
06:50 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ******NO MECHANICAL DETAILS PROVIDED**** | | | PROVIDE DETAILS FOR MECHANICAL REVIEW | | | AT TIME OF MECHANICAL PERMIT APPLICATION | | | INCLUDE BATH EXHAUST, AIR DISTRIBUTION, | | | EQUIPMENT SIZES, OUTSIDE AIR CALCULATION | | | W/ AIR BALANCE SCHEDULE, AND FIRE PROTEC | | | TION REQUIREMENTS FOR EQUIPMENT SHUTDOWN | | | AND FIRE SEPARATION REQUIREMENTS OF | | | SPACES. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
10 |
Status |
P |
Date |
2002-08-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-08-06 |
Time |
08:04 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-08-06 |
Time |
08:04 |
Sent To |
|
|
| Notes |
| 2002-08-06 00:00:00 | REVISION FOR WATER METER AND WATER | | | SERVICE CHANGE - SIGNED/SEALED LETTER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
9 |
Status |
F |
Date |
2002-08-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-08-05 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-08-05 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2002-08-05 00:00:00 | DENIED | | | | | | CHANGES TO A SIGNED AND SEALED SHALL BE | | | SIGNED AND SEALED ALSO. LETTER SUBMITTED | | | 7-29-02 SHALL BE SIGNED AND SEALED BY | | | ENGINEER/ARCHITECT OF RECORD. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
8 |
Status |
F |
Date |
2002-07-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-07-17 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-07-17 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2002-07-17 00:00:00 | DENIED | | | REFERENCE: SPC-94 | | | | | | 1) PLEASE SUBMIT PLANS THAT ARE SIGNED | | | AND SEALED BY THE ARCHITECT OF RECORD. | | | 2) TOILET ROOM SHALL SHOW ALL DIMENTIONS | | | AND SHOW DETAIL FOR COMPLIANCE WITH | | | FACBC-97 FOR TOILET ROOM AND ALL FIXTUR- | | | ES. SEC 4.22 AND ALL SUBSECTIONS. SHOW | | | UNOBSTURCTED 5' TURNING RADIUS. W/C | | | SHALL NOT INTRUDE INTO TURNING RADIUS. | | | 3) SHOW LOCATION AND DETAIL FOR DRINKING | | | FOUNTAIN. COMPLY WITH 4.15 AND ALL SUB- | | | SECTIONS, AND 4.1.3(10)(A) FOR THOSE WHO | | | HAVE DIFFICULITY BENDING OR STOOPING. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
P |
Date |
2001-06-08 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-06-08 |
Time |
13:22 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-06-08 00:00:00 | PLUMBING PLAN REVIEW 7TH TIME,PROVISO. | | | (1)SHT A4 ROOF DRAINAGE, 6" GUTTER , | | | 8" DOWMSPOUT,CONNECTED TO SITE STORM. | | | (2) SHT P1,WATER AND SANITRY SEWER AT | | | EACH FUTURE TENNANT SPACE,SHELL ONLY. | | | (3) EA FUTURE TENNANT SPACE TO PROVIDE | | | 1-W/C,1-LAV,1-D/F.TO COMPLY WITH FACBC97 | | | SEC 4.16 CLEAR FLR SPACE FOR W/C, SEE | | | FIGURE 28, PG 107. | | | END OF COMMENTSPAUL SCHMITZ | | | QUESTIONS 561-659-8096X8233 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
F |
Date |
2001-05-29 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-05-29 |
Time |
19:16 |
Rev Time |
2.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-05-29 00:00:00 | PLUMBING PLAN REVIEW 6TH TIME DENIED | | | THIS PERMIT WILL NOT BE ISSUED UNTIL ALL | | | COMMENTS ARE ADDRESSED. | | | (1) SHT A-5 PROVIDE INFORMATION ON | | | ROOF DRAINAGE,GUTTER AND DOWN SPOUTS, | | | SIZE AND NUMBER.SPC 94 SEC 1101.2 | | | (2)DWV ISOMETRIC FOR EA PLUMBING | | | FIXTURE, WITH PIPE SIZES SPC94 SEC 104.3 | | | (3) SHT A-6,A-10 H/C REST RM'S COMPLY | | | WITH FACBC 97 SEC 4.16& FIG 28. | | | SHOW SCALE OF DETAIL,CLEAR FLR SPACE. | | | (4) SHT A-6 COMPLY W/FACBC 97 SEC 4.15.5 | | | & FIG 27,FOR A H/C DRINKING FOUNTAIN. | | | (5) SHT P-1.0 SHOW LOCATION & TYPE OF | | | BACK FLOW PREVENTER. SPC-97 SEC 606. | | | END OF COMMENTS PAUL SCHMITZ | | | QUESTIONS 561-659-8096X 8233 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-07-17 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2001-05-05 00:00:00 | DENIED 5TH TIME, PLEASE ADDRESS | | | PREVIOUS NOTES DATED 03-02-01 BY JHL | | | END OF COMMENTS PAUL SCHMITZ | | | QUESTIONS 561-659-8096 X 8233 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2001-03-02 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-03-02 |
Time |
15:14 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2001-03-02 |
Time |
15:14 |
Sent To |
|
|
| Notes |
| 2001-03-02 00:00:00 | DENIED; | | | | | | 1.HANDICAP BATHROOMS MUST COMPLY WITH | | | FACBC 4.17.3.SHOW REQUIRED TURNING | | | SPACE IN TOILET ROOM. | | | | | | 2.SHOW HOW ROOF WILL DISCHARGE RAIN | | | WATER FROM ROOF. | | | | | | 3.SUBMIT SANITARY AND WATER DIAGRAMS FOR | | | PLUMBING WORK TO BE INSTELLED UNDER | | | THIS PERMIT. COUNTY AMENDMENTS TO SPC | | | 104.2.1. | | | | | | 4.DRINKING FOUNTAINS ARE REQUIRED IN | | | EACH BAY PER SPC TABLE 407. FOUNTAINS | | | SHALL COMPLY WITH FACBC 4.1.3 (10) AND | | | 4.L15 | | | | | | 5.SHOW UNDER GROUND. STORM DRAINAGE, | | | BUILDING SEWER, WATER LINES AND | | | BACKFLOW PREVENTER ETC. | | | | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT.8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2000-08-09 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-08-09 |
Time |
18:55 |
Rev Time |
0.65 |
| Received By |
tlarge |
Date |
2000-08-09 |
Time |
18:45 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)ALL PLANS SHALL BE SIGNED AND SEALED | | | PER COUNTYWIDE AMENDMENTS TO SPC SEC. | | | 104.2.3. | | | | | | 2)SUBMIT SANITARY AND WATER DIAGRAMS FOR | | | PLUMBING WORK TO BE INSTALLED UNDER THIS | | | PERMIT.COUNTYWIDE AMENDMENTS TO SPC SEC. | | | 104.2.1. | | | | | | 3)SUBMIT SQUARE FOOTAGE OF EACH BAY.SHOW | | | LXW TO ENSURE COMPLIANCE W/SPC TABLE 407 | | | | | | 4)DRINKING FOUNTAINS ARE REQD.IN EACH | | | BAY PER SPC TABLE 407.FOUNTAINS SHALL | | | COMPLY W/FACBC SEC.4.1.3.(10)(A),4.15. | | | PROVISIONS SHALL BE MADE FOR PEOPLE WHO | | | HAVE TROUBLE BENDING OR STOOPING. | | | | | | 5)GRAB BARS ALONGSIDE WATER CLOSETS | | | SHALL BE 42" PER FACBC 4.16.4.(THE | | | HANDICAP DETAILS ON SHT.A-6.0 ARE FOR A | | | STALL AND DO NOT COMPLY W/FACBC.COMPLY | | | W/FACBC SEC.4.16. | | | | | | 6)SHOW REQD.WHEELCHAIR TURNING SPACE IN | | | TOILET ROOMS PER FACBC SEC.4.2.3. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2000-05-20 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2000-05-20 |
Time |
13:22 |
Rev Time |
2.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PLUMBING PLAN REVIEW | | | 2ND TIME DENIED | | | (1) SUBMIT DWV AND WATER LINE DIAGRAMS, | | | SHOW LOCATION OF BACK FLOW PREVENTER, | | | WATER HEATERS,AND SEPERATE WATER SUPPLY | | | TO EACH UNIT WITH SHUT OFF VALVE. | | | SPC 94 SEC 101.4.6 | | | (2) COMPLY WITH FACBC SEC 4.2.3,4.16, | | | 4.19.3.CLEAR FLOOR SPACE FOR WHEELCHAIR | | | IN FRONT OF WATER CLOSET,LAV. | | | (3) DRINKING FOUNTAIN REQUIRED FOR EACH | | | UNIT SPC 94 TAB 407. | | | COMPLY WITH FACBC 4.1.3 (10)(A),4.15. | | | END OF COMMENTS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
1999-12-03 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-12-03 |
Time |
18:02 |
Rev Time |
0.75 |
| Received By |
pschmitz |
Date |
1999-12-03 |
Time |
18:02 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SUBMIT WATER AND SANITARY RISER DIAGRAMS | | | FOR REVIEW PER COUNTYWIDE AMENDMENTS | | | TO SPC SEC.104.2.1. | | | | | | SHOW REQD.CLEAR FLOOR SPACES FOR WATER | | | CLOSET AND LAV AND SHOW REQD.WHEELCHAIR | | | TURNING SPACE PER FACBC SEC.4.2.3.,4.16, | | | 4.19.3. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2001-05-16 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-05-16 |
Time |
08:57 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-05-16 00:00:00 | PROVISO: MOVE HC SPACE TO BE CENTRAL TO | | | BOTH BUILDING | | | 2. DOOR OPENING UP INTO SEPARATE PARCEL |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2001-03-20 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-03-20 |
Time |
11:51 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-03-20 00:00:00 | SEE ATTACHED LIST LANDSCAPE ARCHITECT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2000-05-16 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-05-16 |
Time |
09:05 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DOES NOT MEET PARKING REQUIREMENTS |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
1999-11-09 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
1999-11-09 |
Time |
09:23 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NEEDS CONCURRENCY |
|
|