| Plan Review Stops For Permit 99100387 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2000-04-21 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2000-04-21 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2000-04-20 |
Time |
16:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2000-03-03 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2000-03-03 |
Time |
15:26 |
Rev Time |
99.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SAME AS FIRST |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
1999-12-16 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
1999-12-16 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2000-09-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-09-21 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-09-21 |
Time |
12:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2000-08-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-08-29 |
Time |
20:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-08-29 |
Time |
20:46 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************** UNSAT ***************** | | | | | | 1)NOTE:AS ASKED FOR ON FIRST SET OF NOTE | | | -S. PLEASE SUBMIT LOAD CALCULATIONS. | | | PLEASE SHOW,,,WITH SQFT/CONTINUOUS LOADS | | | AT 125% ETC. | | | | | | 2)NOTE: PLEASE SUBMIT AND SHOW ALL AIC | | | RATING FOR ALL MAINS/PANELS BEING INSTAL | | | -LED.EQUIPMENT MUST BE RATED FOR THE | | | AVAILABLE FAULT CURRENT PER 110-9 | | | | | | \\3)NOTE PLEAS SUBMIT AND SHOW GROUNDING | | | ELECTRODE SYSTEM. 250-50 BLDG STEEL AND | | | COLD WATER ETC. | | | | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMAITON | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
1999-11-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
1999-11-01 |
Time |
07:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
1999-11-01 |
Time |
20:44 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ****************PROVISO**************** | | | | | | 1)NOTE:NEED TO SUBMIT LOAD CALCULATIONS | | | OF SERVICE AND LOAD CALCULATION FOR EACH | | | PANEL.AS PER 215-5 | | | 2)SUBMIT LOAD ON COOK CENTER PANEL. | | | NEED TO SUBMIT THE ABOVE INFORMATION | | | FOR REVIEW AND APPROVAL BEFORE ROUGH | | | SLAB INSPECTION IS CALLED IN!!!! |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2000-08-23 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
1999-11-30 |
Time |
10:56 |
Rev Time |
0.25 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PLANS HAVE BEEN REVIEWED AT UTILITIES | | | DEPARTMENT AT 45TH ST. ON OCT 22, 1999 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2000-08-23 |
|
|
Cont ID |
|
| Sent By |
dlauderm |
Date |
1999-11-08 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
1999-11-04 |
|
|
Cont ID |
|
| Sent By |
dlauderm |
Date |
1999-11-04 |
Time |
10:40 |
Rev Time |
0.25 |
| Received By |
dlauderm |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | STORMWATER, WATER AND SANITARY ALREADY | | | APPROVED THRU SEPARATE REVIEWS AT ENG. | | | SERVICES.SERVIES FOR SW, SS,WILL | | | BE INSTALLED VIA HOME DEPOT PLAN. | | | SANITATION COMMENTS.APPROVED WITH | | | PREVISO: OPENING OF STANDARD TRASH | | | ENCLOSURE PLANS, ON PAGE C6 (BOT. RIGHT | | | AND TOP RIGHT)DO NOT MATCH. THE GATES | | | MUST HAVE A 12' OPENING BETWEEN THE | | | GATE POSTS.ADDITIONALLY THE WIDTH OF | | | THE OPEN AREA BETWEEN THE CONCRETE WALLS | | | IS 22' - 8", IT MUST BE OVER 24' WIDE TO | | | TAKE TWO GATES AND TWO GATE POSTS AS | | | SHOWN ON THE TOP RIGHT DRAWING OF PAGE | | | C6.THE DRAWING ALSO CONFLICTS WITH THE | | | DRAWING ON PAGE 2 OF THE BUILDING PLAN | | | IT SHOWS ONLY 11' FROM THE CENTER OF THE | | | GATE POSTS. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2000-08-22 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-08-22 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-08-22 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PLAN WAS APPROVED PROVISO BY RHETT | | | TURNQUEST ON 12/7/99 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2000-09-05 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-09-05 |
Time |
10:58 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2000-09-05 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NOTE: | | | SEPARATE PERMIT REQUIRED FOR HOOD, SUPP- | | | RESSION SYSTEM AND WALKIN COOLER FREEZER | | | PROVIDE PLANS AT TIME OF PERMIT APPLICA- | | | TION FOR THESE SYSTEMS. | | | DUCT WRAP FOR GREASE EXHAUST DUCT TO | | | HAVE SUBMITTED AT TIME OF PERMIT APPLIC- | | | ATION THE PRODUCT APPROVAL INFORMATION | | | FOR THE DUCT WRAP MATERIAL FOR APPROVAL | | | PRIOR TO INSTALLATION |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
1999-12-02 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
1999-12-02 |
Time |
07:35 |
Rev Time |
0.50 |
| Received By |
ndenmark |
Date |
1999-12-02 |
Time |
07:35 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO: | | | ADDITIONAL MECHANICAL PERMITS REQUIRED | | | FOR HOODS, SUPPRESSION SYSTEMS, AND WALK | | | IN COOLER/ FREEZER. SUBMIT PLANS WITH | | | MECHANICAL PERMIT APPLICATIONS | | | CLEARANCE TO COMBUSTIBLES FOR HOOD AND | | | DUCT TO BE 18" MIN. OR CLEARANCE REDUCT- | | | ION IN ACCORDANCE WITH 1997 SMC 504.4 | | | AND 505.12 | | | EXHAUST TERMINATION TO BE MIN. 10' FROM | | | ANY OUTSIDE AIR INTAKE |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2000-09-03 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-09-03 |
Time |
06:44 |
Rev Time |
0.65 |
| Received By |
tlarge |
Date |
2000-09-03 |
Time |
06:35 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)HORIZONTAL DRY VENTS NOT PERMITTED PER | | | SPC SEC.906.2.1.(SEE FLOOR SINKS,FLOOR | | | DRAINS.) | | | | | | 2)GREASE INTERCEPTOR SHALL COMPLY W/CITY | | | OF WPB ENGINEERING STANDARDS. | | | | | | 3)WATER SUPPLY CONTROL SHALL COMPLY W/ | | | SPC SEC.610.4.1,610.4.2. | | | | | | 4)SERIES OF FLOOR DRAINS AND FLOOR SINKS | | | SHALL COMPLY W/SPC SEC.921 FOR HORIZ. | | | COMBINATION WASTE AND VENT SYSTEM. | | | | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | | ANY QUESTIONS. | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2000-04-24 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-04-24 |
Time |
07:59 |
Rev Time |
1.00 |
| Received By |
tlarge |
Date |
2000-04-24 |
Time |
07:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2000-02-28 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-02-28 |
Time |
10:34 |
Rev Time |
3.25 |
| Received By |
tlarge |
Date |
2000-02-28 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SIZE AND DESIGN OF GREASE TRAP SHALL BE | | | APPROVED BY CITY OF WPB UTILITIES.SUBMIT | | | APPROVAL FORM FROM UTILITIES.CONTACT | | | R.COMPO AT (561)835-7423 FOR INFO. | | | | | | PLANS SHALL BE ROUTED TO FLA.DEPT.OF | | | BUSINESS REGULATION FOR REVIEW AND | | | APPROVAL PRIOR TO REVIEW BY THIS DEPT. | | | COUNTYWIDE AMENDMENTS TO SPC SEC.101.4.7 | | | | | | URINAL SHALL BE ARRANGED TO ALLOW FOR | | | PRIVACY PER SPC SEC.404.3.(URINAL IS | | | LOCATED IN LINE OF SIGHT FROM CORRIDOR) | | | | | | HUB DRAINS NOT PERMITTED PER SPC.FLOOR | | | DRAINS OR FLOOR SINKS SHALL BE INSTALLED | | | PER SPC 407 & 408. | | | | | | VENTING OF FLOOR DRAINS AND FLOOR SINKS | | | SHALL COMPLY W/TABLE 908.1. | | | | | | WATER SUPPLY CONTROL FOR THE RESTROOMS | | | SHALL COMPLY W/SPC SEC.610.4.1. | | | | | | DRY VENTS NOT PERMITTED PER SPC 906.4 | | | | | | SHOW HEIGHT OF TOILET PAPER DISPENSER | | | PER FACBC FIG.30. | | | | | | SHOW VTR FOR TOILET ROOM OR CONNECTION | | | TO STACK VENT.SPC SEC.904.2.1. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2000-02-20 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-02-20 |
Time |
12:26 |
Rev Time |
0.50 |
| Received By |
tlarge |
Date |
2000-02-20 |
Time |
12:26 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | TWO COMPLETE COPIES OF PLANS SHALL BE | | | SUBMITTED.THE COPIES ARE EXTREMELY | | | DISORGANIZED AND DIFFICULT TO REVIEW IN | | | THIS MANNER.PLANS,SPECIFICATIONS,DETAILS | | | AND REVISIONS SHALL BE COMPILED BY | | | OWNER'S REPRESENTATIVE IN AN ORDERLY | | | FASHION FOR A PROPER AND THOROUGH PLAN | | | REVIEW BY THIS DEPT.COUNTYWIDE AMENDMENT | | | TO SPC SEC.104.2.1`. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
1999-11-01 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
1999-11-01 |
Time |
11:39 |
Rev Time |
3.25 |
| Received By |
tlarge |
Date |
1999-10-26 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | INDICATE SIZE OF GREASE TRAP ON PLANS. | | | CONTACT RODNEY COMPO AT CITY OF W.P.B. | | | REGIONAL WASTEWATER TREATMENT PLANT AT | | | (561)835-7423 FOR SIZE REQS. | | | | | | PLANS SHALL BE ROUTED TO DEPT.OF | | | BUSINESS AND PROFESSIONAL REGULATION FOR | | | REVIEW AND APPROVAL PRIOR TO REVIEW BY | | | THIS AGENCY.SPC SEC.101.4.7. | | | | | | URINAL SHALL BE ARRANGED TO ALLOW FOR | | | PRIVACY PER SPC SEC.404.3.(LOCATED IN | | | LINE OF SIGHT IN CORRIDOR.) | | | | | | HUB DRAINS NOT PERMITTED BY SPC.FLOOR | | | DRAINS OR FLOOR SINKS SHALL BE INSTALLED | | | PER SPC 407 AND SPC 807. | | | | | | LOCATION OF GREASE TRAP SHALL COMPLY W/ | | | SBC SEC.1803.1.3. | | | | | | FLOOR DRAINS ARE NOT PROPERLY VENTED PER | | | SPC 901.2 AND TABLE 908.1. | | | | | | VENTS CANNOT BE INCREASED IN SIZE .(ONLY | | | IN AREAS WHERE FROST IS A FACTOR.)SPC | | | SEC.905.2. | | | | | | WATER CLOSETS ARE NOT PROPERLY VENTED | | | PER SPC SEC.901.2 | | | | | | SIZE THE WATER SUPPLY SYSTEM IN ITS | | | ENTIRETY.SPC SEC.104.2.1. | | | | | | WATER SUPPPLY CONTROL FOR THE RESTROOMS | | | SHALL COMPLY W/SPC SEC.610.4.2. | | | | | | SUBMIT GAS DRAWING IF APPLICABLE.SPC | | | 104.2.1. | | | | | | DRY VENTS ARE NOT PERMITTED ON W.C.'S | | | PER SPC SEC.906.4. | | | | | | SHOW HT. OF TOILET PAPER DISPENSER | | | ON PLANS .COMPLY W/FACBC FIG 30. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2000-08-23 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2000-08-23 |
Time |
08:54 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PER A JONES |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
1999-12-16 |
Time |
14:36 |
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|