Plan Review Details - Permit 99100289
Plan Review Stops For Permit 99100289
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2000-08-17 Cont ID  
Sent By hpiskura Date 2000-08-17 Time 09:40 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2000-07-17 Cont ID  
Sent By hpiskura Date 2000-07-17 Time 09:15 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2000-06-16 Cont ID  
Sent By hpiskura Date 2000-06-16 Time 15:48 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2001-01-08 00:00:00SAME AS SECOND

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2000-03-03 Cont ID  
Sent By hpiskura Date 2000-03-03 Time 11:22 Rev Time 99.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 1999-11-09 Cont ID  
Sent By hpiskura Date 1999-11-09 Time 15:56 Rev Time 99.00
Received By hpiskura Date   Time   Sent To Z
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2001-11-06 Cont ID  
Sent By dpalmer Date 2001-11-06 Time 21:48 Rev Time 0.00
Received By dpalmer Date 2001-11-06 Time 21:48 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2001-02-14 Cont ID  
Sent By dpalmer Date 2001-02-14 Time 10:02 Rev Time 0.00
Received By dpalmer Date 2001-02-14 Time 10:02 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-06-13 Cont ID  
Sent By dpalmer Date 2000-06-13 Time 20:08 Rev Time 0.00
Received By dpalmer Date 2000-06-13 Time 20:08 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-10-29 Cont ID  
Sent By jleahy Date 1999-10-29 Time 13:49 Rev Time 1.15
Received By jleahy Date 1999-10-29 Time 13:45 Sent To  
Notes
2001-01-08 00:00:001)PROVIDE AIC RATINGS FOR PANELS H,HA
  
 2)PROVIDE PANEL SCHEDULE FOR PANEL PA
  
 3)PROVIDE THIS INFORMATION PRIOR TO
 THE FIRST ELECTRICAL ROUGH INSPECT.

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2000-08-08 Cont ID  
Sent By dlauderm Date 2000-08-08 Time 13:32 Rev Time 0.00
Received By dlauderm Date 2000-08-08 Time 13:32 Sent To  
Notes
2001-01-08 00:00:00PASSED WITH PROVISOS:
 ONLY THE CLUB HOUSE BUILDING IS APPROVED
 NOT ENOUGH INFO HAS BEEN SUPPLIED FOR
 THE SITE TO REVIEW IT.SUCH AS:
 WHERE WILL THE DUMPSTER GO?
 WHERE IS THE PARKING LOT PLANS?
 WHERE ARE THE WATER PLANS?
 WHERE ARE THE SANITARY SEWER PLANS?
 WHERE ARE THE POLLUTION CONTROL PLANS?
 THIS IS DOUBLY IMPORTANT SINCE THE
 CONTRACTOR IS WORKING ON THE SITE.
 HOW CAN THE CONTRACTOR BE WORKING ON THE
 SITE WITH OUT A CLEARING PERMIT.
 WHERE IS THE STORMWATER PLANS?

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 1999-11-30 Cont ID  
Sent By dlauderm Date 1999-11-30 Time 12:57 Rev Time 0.50
Received By dlauderm Date 1999-11-30 Time 12:56 Sent To  
Notes
2001-01-08 00:00:00STORM WATER REQUIREMENTS: TO OBTAIN A
 CONSTRUCTION PERMIT. THE FOLLOWING MUST
 BE SUBMITTED SIGNED AND SEALED BY A
 FLORIDA PROFESSIONAL ENGINEER (PE):
 1) CONSTRUCTION PLANS,
 2) DETAILS AND SPECIFICATIONS,
 3) HYDRAULIC COMPUTATIONS AND
 SUPPORTING DOCUMENTATION,
 4) IMPERVIOUS AREA COMPUTATIONS,
 POLLUTION PREVENTION PLAN.
 THE POLLUTION PREVENTION PLAN SHALL BE
 KEPT ON SITE AT ALL TIMES DURING
 CONSTRUCTION. THE PLAN SHALL BE
 INSTALLED IN THE FIELD PRIOR TO ANY
 EARTHWORK. THE ENGINEER OF RECORD
 SHALL CERTIFY TO THE CITY, ON A MONTHLY
 BASIS, THAT THE PLAN IS WORKING PROPERLY
 AND AS DESIGNED. THE ENGINEER OF RECORD
 IS RESPONSIBLE TO CERTIFY
 IMPLEMENTATION OF THE PROVISIONS OF
 CITY ORDINANCE NO. 3132-98 OF THE CITY
 CODE AT SUCH TIME THE PERMITTEE APPLIES
 FOR A CERTIFICATE OF OCCUPANCY FROM THE
 CITY BUILDING OFFICIAL.
 EVERY SIX MONTHS AFTER CONSTRUCTION A
 PE SHALL CERTIFY THAT THE PERMANENT
 POLLUTION PREVENTION STRUCTURES, DRY-
 WET WATER DETENTION FACILITIES, AND
 EXFILTRATION SYSTEMS ARE WORKING AS
 DESIGNED AND ARE IN GOOD OPERATING
 CONDITION.
 ALL CERTIFICATIONS MUST BE SUBMITTED
 TO: STORM WATER UTILITY ENGINEER, CITY
 OF WEST PALM BEACH, PUBLIC UTILITIES
 DEPARTMENT, P.O. BOX 3366, WEST PALM
 BEACH, FLORIDA 33402. THE CERTIFICATION
 MUST INCLUDE THE BUILDING PERMIT
 NUMBER, THE ADDRESS OF THE PROPERTY AND
 THE NAME OF THE ESTABLISHMENT/PROJECT
 CONSTRUCTED.
 SANITATION:
 NO DUMPSTER ENCLOSURE SHOWN. STATE IF IT
 IS TO BE CITY PICK UP OR PRIVATE.IF
 CITY PICKUP THEN THE FOLLOWING
 REQUIREMENTS MUST BE MET; DUMPSTER MUST
 HAVE A MINIMUM OF 12' OPENING BETWEEN
 THE GATE POSTS.INTERIOR DIMENSIONS OF
 THE ENCLOSURE MUST BE A MINIMUM OF 12'
 WIDE AND 12' DEEP.A CONCRETE PARKING
 STOP BAR MUST BE CENTERED (FROM GATES)
 AND INSTALLED 18" FROM THE BACK WALLED.
 STEEL BARS WILL BE DRILLED OR THRU THE
 STOP BAR AND INTO THE INTERIOR FLOOR OF
 THE ENCLOSURE TO STOP THE BAR FROM MOVIN
 WHEN THE DUMPSTER IS SET INSIDE. THE
 OPENING OF THE DUMPSTER ENCLOSURE MUST
 BE PLACED SO THAT A 40' LONG TRUCK WITH
 THE FORKS EXTENDED CAN APPROACH THE
 OPENING AND PICK UP THE DUMPSTER WITHOUT
 TURNING A SHARP TURN. NOTHING MAY BE
 PLACED OVERHEAD IN THE AREA WHERE THE
 DUMPSTER ENCLOSURE IS SO THAT WHEN THE
 DUMPSTER IS PICKED UP AND DUMPED THE
 DUMPSTER NOR THE TRUCK OR TRUCK FORKS
 WILL BE IMPEDED.
 WATER AND SANITARY APPROVED WITH DEP PER
 THE CORE ROAD PALNS.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 1999-11-03 Cont ID  
Sent By rturnque Date 1999-11-03 Time 15:04 Rev Time 0.15
Received By rturnque Date   Time   Sent To  
Notes
2001-01-08 00:00:00FIRE ALARM SYSTEM SHALL BE CLASS "A" OR
 ADDRESSABLE. PROVIDE SMOKE DETECTOR ABOV
 FIRE ALARM CONTROL PANEL.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2000-06-09 Cont ID  
Sent By ndenmark Date 2000-06-09 Time 15:02 Rev Time 0.50
Received By ndenmark Date 2000-06-09 Time 15:02 Sent To  
Notes
2001-01-08 00:00:00PASSED WITH SAME PROVISO AS PREVIOUSLY
 NOTED

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-11-23 Cont ID  
Sent By ndenmark Date 1999-11-23 Time 11:29 Rev Time 0.50
Received By ndenmark Date 1999-11-23 Time 11:29 Sent To  
Notes
2001-01-08 00:00:00PROVISO:
 TEST AND BALANCE REPORT SHOWING REQUIRED
 QUANTITIES OF AIR INCLUDING OUTSIDE AIR
 TO BE SUBMITTED PRIOR TO FINAL

Review Stop P PLUMBING
Rev No 7 Status P Date 2001-05-01 Cont ID  
Sent By kstevens Date 2001-05-01 Time 09:00 Rev Time 1.50
Received By kstevens Date 2001-05-01 Time 08:59 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 6 Status P Date 2001-03-31 Cont ID  
Sent By jleech Date 2001-03-31 Time 11:09 Rev Time 1.00
Received By jleech Date 2001-03-31 Time 11:08 Sent To  
Notes
2001-03-31 00:00:00VALVE BOXES SHALL COMPLY WITH 94 SPC
 610.1

Review Stop P PLUMBING
Rev No 5 Status P Date 2000-08-11 Cont ID  
Sent By tlarge Date 2000-08-11 Time 14:34 Rev Time 0.65
Received By tlarge Date 2000-08-11 Time 14:34 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status F Date 2000-08-05 Cont ID  
Sent By tlarge Date 2000-08-05 Time 08:14 Rev Time 1.50
Received By tlarge Date 2000-08-05 Time 08:12 Sent To  
Notes
2001-01-08 00:00:001)THE NUMBER OF WATER CLOSETS REQUIRED
 FOR THE FEMALES SHALL COMPLY W/FLA.
 STATUTE 553.141.(POTTY PARITY.A 3:2
 RATIO,FEMALES TO MALES, IS REQD.
  
 2)THE CORRECT OCCUPANT FOR PLUMBING FIX-
 TURES SHALL BE BASED ON 70 SQ.FT.PER
 PERSON.DO THE MATH AND NOTECORRECT
 OCCUPANT LOAD ON PLANS.SPC 407.1.3.
  
 3)SHT.A-2-THE MIN.WIDTH OF THE HANDICAP
 TOILET STALLS SHALL COMPLY FACBC SEC.
 4.17.3.(MIN.WIDTH 83".)REVISE ON PLANS.
  
 4)HEIGHT OF WATER CLOSET AND CLEAR FLOOR
 SPACE UNDER LAV.SHALL COMPLY W/FACBC
 SEC.4.19.2,417.3.
  
 5)SHT.P-4-DRINKING FOUNTAIN SHALL
 CONNECT TO SANITARY SYSTEM.SPC SEC.
 301.11.1.
  
 6)PLANS REFER TO SHT.ME-1 FOR CONTIN-
 UATION.SUBMIT SHT.ME-1 FOR REVIEW.
  
 IF YOU HAVE ANY QUESTIONS CALL
 561-659-8096,EXT.8377.
  
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.

Review Stop P PLUMBING
Rev No 3 Status F Date 2000-06-09 Cont ID  
Sent By tlarge Date 2000-06-09 Time 09:57 Rev Time 1.75
Received By tlarge Date 2000-06-09 Time 09:57 Sent To  
Notes
2001-01-08 00:00:00SHOWERS SHALL COMPLY W/FACBC SEC. 4.21.2
 (THE DIMENSIONS SHALL COMPLY W/FACBC
 FIG.35 (A) OR (B).
  
 SHT.A9.5-LAVATORY CLEARANCES SHALL
 COMPLY W/FACBC SEC.4.19.2.
  
 HEIGHT OF WATER CLOSET SHALL BE 19"AFF
 PER FACBC SEC.4.16.3.
  
 INDICATE THE CORRECT OCCUPANT LOAD PER
 SPC SEC.407.1.3.THE FACILITY DOESN'T
 COMPLY W/TABLE 407 FOR THE MINIMUM
 REQD.FIXTURES AND POTTY PARITY.
  
 PLANS REFER TO PLUMBING SHEET P-4 AND
 SHEET P-4 IS NOT WITH SUBMITTED PLANS.
 COUNTYWIDE AMENDMENTS TO SPC SEC.104.2.1
  
 SHT.P-1-8"OVERFLOW DRAINING INTO 6"LINE.
 COMPLY W/SPC SEC.307.5.

Review Stop P PLUMBING
Rev No 2 Status F Date 2000-02-05 Cont ID  
Sent By tlarge Date 2000-02-05 Time 09:50 Rev Time 1.50
Received By tlarge Date 2000-02-05 Time 08:48 Sent To  
Notes
2001-01-08 00:00:00SHOWERS SHALL COMPLY FULLY COMPLY
 W/FACBC SEC.4.21.2.(THE DIMENSIONS SHALL
 COMPLY W/FACBC FIG.35 (A) OR (B).
  
 SHOWER CONTROLS SHALL COMPLY W/FACBC
 SEC.4.21.5.CLEARLY SHOW MIN.AND MAX.
 DIMENSIONS.
  
 SHT.A-9.5-LAVATORY CLEARANCES SHALL
 COMPLY W/FACBC 4.19.2
  
 SHOW HEIGHT OF WATER CLOSET PER FACBC
 SEC.4.16.3.
  
 INDICATE THE CORRECT OCCUPANT LOAD PER
 SPC SEC.407.1.3. THE FACILITY DOESN'T
 COMPLY W/TABLE 407 FOR THE MINIMUM REQD.
 FIXTURES.
  
 NO URINALS PERMITTED ON WET VENT PER
 SPC 911.1(2)EXCEPTION.
  
 CIRCUIT AND LOOP SYSTEM IN MEN'S ROOM
 SHALL COMPLY W/SPC SEC.914.1.(VENT REQD.
 IN FRONT OF LAST UPSTREAM FIXTURE DRAIN.
  
 WATER SUPPLY CONTROL SHALL COMPLY W/SPC
 SEC.610.4.1,610.4.2.
  
 PLANS REFER TO PLUMBING SHEET P-4 AND
 CIVL DRAWINGS.NEITHER HAVE BEEN SUB-
 MITTED.
  
 DESIGNATE ONE SIZE OVERFLOW DRAIN FOR
 THE STORM SYSTEM. (EITHER 6" OR 8")
  
 DRINKING FOUNTAIN SHALL COMPLY W/FACBC
 SEC.4.1.3(10)(A).(PROVISIONS SHALL BE
 MADE FOR PERSONS WHO HAVE TROUBLE BEND-
 ING OR STOOPING.

Review Stop P PLUMBING
Rev No 1 Status F Date 1999-11-06 Cont ID  
Sent By tlarge Date 1999-11-06 Time 07:02 Rev Time 2.50
Received By tlarge Date 1999-11-06 Time 07:02 Sent To  
Notes
2001-01-08 00:00:00SHOWERS SHALL FULLY COMPLY W/FACBC SEC.
 4.21.2.SUBMIT DETAIL OF SHOWER .SHOW ALL
 HEIGHT DIMENSIONS
  
 THE SIZE OF THE HANDICAP TOILET STALLS
 SHALL COMPLY W/FACBC SEC.4.17.SEE
 EXCEPTION:NEW CONSTRUCTION AND FIG
 30 (A).
  
 CLEARLY SHOW THAT FLOORS AND WALLS IN
 TOILET ROOMS ARE NON-ABSORBENT TO A
 HEIGHT OF 4' PER SBC 1204.2.
  
 SINKS IN ARTS AND CRAFT AND CATERING
 AREAS SHALL COMPLY W/FACBC SECS.4.24.1
 THRU 4.24.7.
  
 URINALS ARE REQD.IN THE MALE RESTROOMS
 PER SPC TABLE 407 FOOTNOTE #3 AND SHALL
 COMPLY W/FACBC SEC.4.18.
  
 SHOW REQD.HEIGHT DIMENSIONS OF ALL
 HANDICAP FIXTURES PER FACBC.
  
 CLEAR FLOOR SPACE FOR SHOWERS SHALL
 COMPLY W/FACBC 4.21.2.
  
 DRINKING FOUNTAIN SHALL COMPLY W/FACBC
 4.1.3.(10)(A).AND 4.15.
  
 SUBMIT CIVIL DRAWINGS FOR CONTINUATION
 OF WATER AND SEWER LINES PER CITY OF WPB
 AMENDMENTS TO STANDARD PLBG.CODE SEC.
 104.2.1.
  
 SUBMIT STORMWATER RISER FOR REVIEW.
  
 CLEARLY SHOW OCCUPANT LOAD ON PLANS.

Review Stop Z ZONING
Rev No 2 Status P Date 2001-09-10 Cont ID  
Sent By sgraham Date 2001-09-10 Time 07:30 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 1999-12-01 Cont ID  
Sent By hpiskura Date 1999-11-09 Time 15:59 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***