Plan Review Details - Permit 99100267
Plan Review Stops For Permit 99100267
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2000-02-15 Cont ID  
Sent By lmartine Date 2000-02-10 Time 08:57 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-01-04 Cont ID  
Sent By lmartine Date 2000-01-04 Time 09:50 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2001-05-09 Cont ID  
Sent By pkrauss Date 2001-05-09 Time 14:40 Rev Time 0.35
Received By pkrauss Date 2001-05-09 Time 14:40 Sent To  
Notes
2001-05-09 00:00:00BUILDING PERMIT 99100267.
  
 PROVISO WRITTEN ON PLAN.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2000-12-26 Cont ID  
Sent By ndenmark Date 2000-12-26 Time 14:19 Rev Time 0.25
Received By ndenmark Date 2000-12-26 Time 14:19 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-11-16 Cont ID  
Sent By ndenmark Date 1999-11-16 Time 07:17 Rev Time 0.25
Received By ndenmark Date 1999-11-16 Time 07:17 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2000-02-11 Cont ID  
Sent By tlarge Date 2000-02-11 Time 15:42 Rev Time 0.75
Received By tlarge Date 2000-02-11 Time 15:42 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2000-02-11 Cont ID  
Sent By tlarge Date 2000-02-08 Time 10:30 Rev Time 0.75
Received By tlarge Date 2000-02-08 Time 10:30 Sent To  
Notes
2001-01-08 00:00:00THE MINIMUM SIZE OF THE HANDICAP ACCESS-
 IBLE STALL PER FACBC IS 79"(THE PLANS
 SHOW 72") AND SPC SEC.403.1 REQUIRES
 ACCESS FOR CLEANING.(A MIN.OF 2"MUST
 BE PROVIDED BETWEEN WALL AND EDGE OF
 LAV.)
  
 YOU DO NOT SHOW THE REQD.FIXTURE CLEAR-
 ANCES FOR THE HANDICAP FIXTURES.COMPLY
 W/FACBC SECS.4.15,4.17,4.4.18,4.19.
  
 SINK IN GREAT ROOM SHALL COMPLY W/FACBC
 SEC.4.24.1-4.24.7.
  
 PROVISIONS SHALL BE MADE AT DRINKING
 FOUNTAIN FOR PERSONS WHO HAVE TROUBLE
 BENDING OR STOOPING PER FACBC SEC.4.1.3.
 (10)(A)

Review Stop P PLUMBING
Rev No 1 Status N Date 2000-02-11 Cont ID  
Sent By tlarge Date 1999-11-05 Time 17:18 Rev Time 1.25
Received By tlarge Date 1999-11-05 Time 17:18 Sent To  
Notes
2001-01-08 00:00:00SUBMIT SQUARE FOOTAGE OF BUILDING AND
 OCCUPANT LOAD.STRUCTURE SHALL COMPLY
 W/SPC TABLE 407 FOR MINIMUM TOILET
 FACILITIES.COMPLIANCE W/FLA.STATUTE
 553.141 PARAGRAPH(1).(POTTY PARITY).
  
 SHT.B-1.HANDICAP STALLS SHALL COMPLY
 W/FACBC SEC.4.17.3.(SEE EXCEPTION:NEW
 CONSTRUCTION.AND FIGURE 30(A).
  
 CLEARLY SHOW REQD.MOUNTING HEIGHT
 DIMENSIONS AND CLEAR FLOOR SPACE UNDER
 PLBG.FIXTURES PER FACBC 1997 EDITION.
  
 SHOW FIXTURE CLEARANCES PER FACBC AND
 SPC SEC.403.4.(SHOW CLEAR FLOOR ACCESS
 FOR URINAL.SEE FACBC SEC.4.18.)
  
 SINK BY GREAT ROOM SHALL COMPLY W/FACBC
 SEC.4.24.1- 4.24.7.
  
 FLOOR DRAIN REQD.IN STAFF TOILET ROOM.
 SPC 409.4.1.1.
  
 WATER HEATER SHALL BE READILY ACCESSIBLE
 PER SPC SEC,501.7.- PROVIDE PERMANENT
 FIXED LADDER OR PLACE HEATER ON FLOOR.
  
 HOT WATER SHALL BE VALVED PER SPC SEC.
 610.4.2.
 .
 DRINKING FOUNTAIN IS NOT SHOWN ON SHT.
 P4.1 AND IS NOT SHOWN ON THE WATER OR
 SANITARY RISER .
  
 SUBMIT COPY OF CIVIL DRAWING SHOWING
 CONTINUATION OF SANITARY AND WATER LINES
 CITY OF WPB AMENDMENTS TO STANDARD PLBG.
 CODE SEC.104.2.1.
  
 DESIGN OF CIRCUIT AND LOOP SYSTEM SHALL
 COMPLY W/SPC SEC.914.1,920.3.
  
 NOTE:THIS IS THE THIRD TIME THIS PLAN
 HAS BEEN REVIEWED AND THE COMMENTS ARE
 BASICALLY THE SAME EACH TIME.THESE ITEMS
 ARE NOT GOING AWAY.MAKE ALL CORRECTIONS
 TO THE PLANS PRIOR TO RESUBMITTAL.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2000-02-15 Cont ID  
Sent By lmartine Date 2000-01-04 Time 09:51 Rev Time 0.00
Received By lmartine Date 2000-02-15 Time 14:27 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2000-02-08 Cont ID  
Sent By gjoyce Date 2000-02-08 Time 09:25 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 1999-10-25 Cont ID  
Sent By gjoyce Date 1999-10-25 Time 11:46 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
2001-01-08 00:00:00NEEDS SITE PLAN AND REVISE LANDSCAPE
 PLAN