Plan Review Details - Permit 99091126
Plan Review Stops For Permit 99091126
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 1999-11-01 Cont ID  
Sent By hpiskura Date 1999-11-01 Time 16:07 Rev Time 99.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-10-20 Cont ID  
Sent By jleahy Date 1999-10-20 Time 14:21 Rev Time 1.30
Received By jleahy Date 1999-10-20 Time 14:21 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 4 Status P Date 2000-12-12 Cont ID  
Sent By mgonzale Date 2000-12-12 Time 07:11 Rev Time 0.50
Received By mgonzale Date   Time   Sent To  
Notes
2001-01-08 00:00:00PASSED
 DRAINAGE AS-BUILTS RECEIVED. C5
 MUST SUBMITT DISK TO
 MANNY GONZALEZ
 PUBLIC UTILITIES ENGINEERING
 1000 45TH ST. WPB, FL 33407
 OR YOU MAY E-MAIL TO
 [email protected]
 THANK YOU.
 PLEASE INCLUDE WATER AND SEWER AS-BUILTS
 AS WELL. 2 MYLAR SETS WILL NEED TO
 BE SUBMITTED FOR WATER AND SEWER SHEET.
 IF ANY QUESTIONS FEEL FREE TO CONTACT
 OUR OFFICE AT 561 659 8040 EXT. 2306

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 1999-12-28 Cont ID  
Sent By lsmith Date 1999-12-28 Time 11:12 Rev Time 1.00
Received By dlauderm Date   Time   Sent To  
Notes
2001-01-08 00:00:00PER DEAN LOUDERMILK 12/28/99 LS

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2000-05-30 Cont ID  
Sent By mgonzale Date 1999-11-30 Time 14:49 Rev Time 1.00
Received By mgonzale Date 1999-11-30 Time 14:51 Sent To  
Notes
2001-01-08 00:00:00COMMENTS BY MANNY GONZALEZ AS PROVISOS
 1. SAMPLE POINT NEEDED AT METER
 2. ON CROSSING 3 AN 18" VERTICAL CLEARAN
 CE REQUIRED BETWEEN WATER AND SANITARY
 3. SHOW PROPOSED SEWER LINE BOLDER
 4. REVISE ALL CROSSINGS TO REFLECT THE
 PROPER PIPE SIZE
 APPROVED WITH PROVISOS
 I HAVE NOTIFIED PETER VANRENZ
 AT KIMLEY HORN TO SUBMITT TRASH
 ENCLOUSURE AND DETAILS.
  
 THE STORM SEWER WAS REVIEWED ON THE
 OVER ALL HOME DEPOT SITE PROJECT
  
 SANITATION:
 NO DUMPSTER ENCLOSURE SHOWN. STATE IF IT
 IS TO BE CITY PICK UP OR PRIVATE.IF
 CITY PICKUP THEN THE FOLLOWING
 REQUIREMENTS MUST BE MET; DUMPSTER MUST
 HAVE A MINIMUM OF 12' OPENING BETWEEN
 THE GATE POSTS.INTERIOR DIMENSIONS OF
 THE ENCLOSURE MUST BE A MINIMUM OF 12'
 WIDE AND 12' DEEP.A CONCRETE PARKING
 STOP BAR MUST BE CENTERED (FROM GATES)
 AND INSTALLED 18" FROM THE BACK WALLED.
 STEEL BARS WILL BE DRILLED OR THRU THE
 STOP BAR AND INTO THE INTERIOR FLOOR OF
 THE ENCLOSURE TO STOP THE BAR FROM MOVIN
 WHEN THE DUMPSTER IS SET INSIDE. THE
 OPENING OF THE DUMPSTER ENCLOSURE MUST
 BE PLACED SO THAT A 40' LONG TRUCK WITH
 THE FORKS EXTENDED CAN APPROACH THE
 OPENING AND PICK UP THE DUMPSTER WITHOUT
 TURNING A SHARP TURN. NOTHING MAY BE
 PLACED OVERHEAD IN THE AREA WHERE THE
 DUMPSTER ENCLOSURE IS SO THAT WHEN THE
 DUMPSTER IS PICKED UP AND DUMPED THE
 DUMPSTER NOR THE TRUCK OR TRUCK FORKS
 WILL BE IMPEDED.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 1999-11-01 Cont ID  
Sent By hpiskura Date 1999-11-01 Time 16:08 Rev Time 0.00
Received By mgonzale Date 1999-10-06 Time 11:19 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-10-20 Cont ID  
Sent By ndenmark Date 1999-10-20 Time 07:46 Rev Time 1.00
Received By ndenmark Date 1999-10-20 Time 07:46 Sent To  
Notes
2001-01-08 00:00:00PROVISO:
 1) FAN SHUT DOWN BY DUCT SMOKE DETECTOR
 REQUIRED FOR AHUS 1,2,3 PER 1997 SMC
 406.1
 2)NOTIFICATION BY HORN AND STROBE OF FAN
 SHUT DOWN REQUIRED BY NFPA 4-4.4.3
 3)ADDITIONAL MECHANICAL PERMITS REQUIRED
 FOR FUEL AND WALK IN COOLER

Review Stop P PLUMBING
Rev No 4 Status P Date 2000-12-09 Cont ID  
Sent By jleech Date 2000-12-09 Time 10:11 Rev Time 0.33
Received By jleech Date 2000-12-09 Time 10:11 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2000-11-27 Cont ID  
Sent By jleech Date 2000-11-27 Time 13:22 Rev Time 0.75
Received By jleech Date 2000-11-27 Time 13:22 Sent To  
Notes
2001-01-08 00:00:00AS BUILDS CAR WASH DRAINAGE AND WATER.

Review Stop P PLUMBING
Rev No 2 Status P Date 1999-11-27 Cont ID  
Sent By tlarge Date 1999-11-27 Time 09:57 Rev Time 1.25
Received By tlarge Date 1999-11-27 Time 09:57 Sent To  
Notes
2001-01-08 00:00:00****************PROVISO*****************
 SUBMIT SHOP DWGS.FOR AIR/WATER & OIL INT
 AT CAR WASH.

Review Stop P PLUMBING
Rev No 1 Status F Date 1999-10-13 Cont ID  
Sent By tlarge Date 1999-10-13 Time 06:47 Rev Time 2.50
Received By tlarge Date 1999-10-13 Time 06:46 Sent To  
Notes
2001-01-08 00:00:00CLEARLY SHOW LOCATION OF GREASE
 INTERCEPTOR ON PLANS.SPC 104.2.1.
  
 CONTACT RODNEY COMPO AT CITY OF W.P.B.
 REGIONAL WASTEWATER TREATMENT PLANT FOR
 GREASE TRAP REQS.(561)835-7423.
  
 MULTIPLE CONDENSATE DRAINS SHALL BE
 SIZED PER STD.MECH.CODE SEC.304.8.4.
  
 RECEPTACLES FOR INDIRECT WASTES SHALL BE
 FLOOR DRAINS OR FLOOR SINKS PER SPC SEC.
 807.
  
 CLEARLY SHOW TERMINATION PT.OF TRENCH
 DRAIN AT CAR WASH.SPC 104.2.1.
  
 VENTING FOR SANITARY SYSTEM SHALL COMPLY
 W/SPC SEC.920.2.
  
 SPACING FOR COPPER TUBE SHALL BE 10'MAX.
 FOR SIZES 2" AND HIGHER PER SPC SEC.
 310.3.4.(REVISE SPECS.)
  
 HOT WATER TO RESTROOMS SHALL BE 110
 DEGREES MAX.PER FLA.ENERGY CODE SEC.
 412.1ABCD.2.3.2.
  
 CONDENSATE DRAINS SHALL TERMINATE PER
 SEC.804.3 OF COUNTYWIDE AMENDMENTS TO
 STD.PLBG.CODE.
  
 DRAINS FROM SODA FOUNTAINS SHALL DRAIN
 TO GREASY WASTE SYSTEM.SPC 1004.1.

Review Stop Z ZONING
Rev No 1 Status P Date 1999-12-28 Cont ID  
Sent By lsmith Date 1999-12-28 Time 11:15 Rev Time 0.50
Received By lsmith Date   Time   Sent To  
Notes
2001-01-08 00:00:00PER SEAN & GRACE 12/28/99